强激光与粒子束, 2017, 29 (10): 103205, 网络出版: 2017-10-30  

传输线长度对静电放电防护器件性能测试的影响

Effect of length of transmission line on performance test of electrostatic discharge protection device
作者单位
1 陆军工程大学石家庄校区 静电与电磁防护研究所, 石家庄 050003
2 武汉理工大学 信息学院, 武汉 430063
摘要
为了研究传输线长度对静电放电防护器件性能测试结果的影响,建立了静电放电模型和传输线脉冲模型两种试验系统,对某限压型防护器件进行了快沿电磁脉冲注入试验,并进行了理论分析。结果表明:传输线长度对静电放电防护器件性能测试结果具有极大影响,选用不当会导致错误结论;在对静电放电防护器件性能测试时,应优先采用传输线脉冲测试法;当采用静电放电脉冲测试法时,其传输线长度不应小于8 m。
Abstract
To study the transient response of electrostatic discharge(ESD) protection device to the EMP with fast rise time, human-metal model (HMM) and transmission line pulse (TLP) current waveforms are widely used for ESD protection devices testing. In this paper, two testing systems were developed. One is an HMM tester, basing on IEC61000-4-2. The other can generate TLP waveform by transmission line charging and discharging. A type of ESD protection device was tested. Transient response waveforms, clamping voltage, clamping time, overshoot voltage were obtained, and the influence of transmission line length on the test results was studied and analyzed theoretically. The experiment results show that: The length of TL has a great impact on the performance testing of an ESD protection device, improper selection can lead to a wrong conclusion; When the ESD protection device is under test, TLP testing is preferred; The length of TL should be less than 8 meters when the ESD pulse testing is used.

张希军, 张莉婷, 王书平, 赵敏. 传输线长度对静电放电防护器件性能测试的影响[J]. 强激光与粒子束, 2017, 29(10): 103205. Zhang Xijun, Zhang Liting, Wang Shuping, Zhao Min. Effect of length of transmission line on performance test of electrostatic discharge protection device[J]. High Power Laser and Particle Beams, 2017, 29(10): 103205.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!