光学与光电技术, 2018, 16 (4): 58, 网络出版: 2018-08-30   

兵器外弹道试验用双源触发装置设计

Design of Double-Source Trigger Device for WeaponExternal Ballistics Test
作者单位
1 西安工业大学光电工程学院, 陕西 西安 710021
2 重庆建设工业(集团)有限责任公司技术中心, 重庆 400054
摘要
针对兵器外弹道试验中采用单一探测传感器易输出误触发信号的技术难题,设计了一种双源触发方案。采用电磁传感器在弹丸击发时输出击发启动信号,采用枪口火焰触发器探测弹丸离开枪口时火光输出火焰停止信号;触发时序控制电路接收到击发启动信号后,输出一个设定宽度的时间窗脉冲信号,在时间窗内接收到火焰触发器输出的停止信号,即可判定为有效触发信号,否则为干扰信号,进行滤除。通过实弹射击验证,每次射击均能可靠输出触发信号,无误触发现象,能够有效提高触发装置的可靠性。
Abstract
In order to solve the technical problems of spurious triggering signal using single detecting sensor in weapon external ballistics measurement, a double-source trigger scheme is put forward in this paper. Shooting start signal is generated by the electromagnetic sensor, and the flame stop signal is generated by flame detector. When the trigger timing control circuit receives the shooting start signal, it can generate a plus signal, whose width dependes on the primer action time. If the flame stop signal is generated at the moment, the circuit can generate trigger signal, otherwise, the signal is a disturb signal. The experimental results show that the trigger signal can be reliably output at every fire without mistake trigger, and the reliability of the trigger system is improved.

田会, 甘学文, 姜波, 段超. 兵器外弹道试验用双源触发装置设计[J]. 光学与光电技术, 2018, 16(4): 58. TIAN Hui, GAN Xue-wen, JIANG Bo, DUAN Chao. Design of Double-Source Trigger Device for WeaponExternal Ballistics Test[J]. OPTICS & OPTOELECTRONIC TECHNOLOGY, 2018, 16(4): 58.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!