Chinese Optics Letters, 2018, 16 (12): 120601, Published Online: Dec. 7, 2018  

Thermal characteristics of Fabry–Perot cavity based on regenerated fiber Bragg gratings Download: 544次

Author Affiliations
1 Beijing Engineering Research Center of Optoelectronic Information and Instrument, Beijing Information Science and Technology University, Beijing 100016, China
2 Beijing Key Laboratory of Optoelectronic Measurement Technology, Beijing Information Science and Technology University, Beijing 100192, China
Abstract
The Letter reports the thermal stability and strain response of Fabry–Perot (FP) cavity under different high temperatures. The FP cavity was made by thermal regeneration of two identical cascaded fiber Bragg gratings (FBGs). It is demonstrated that the FP cavity is capable of measuring temperatures from 300°C to 900°C with a temperature sensitivity of 15.97 pm/°C. The elongation of the fiber was observed through the drifted Bragg wavelength at 700°C or above when weight was loaded. The elongation was further inferred by the slight change in the interference spectra of the FP cavity at 900°C.

Yumin Zhang, Yue Ren, Mingli Dong, Fanyong Meng, Lianqing Zhu. Thermal characteristics of Fabry–Perot cavity based on regenerated fiber Bragg gratings[J]. Chinese Optics Letters, 2018, 16(12): 120601.