分束型同时偏振成像系统定标及预处理方法

Calibration and Preprocessing Method for Amplitude Divided Simultaneous Imaging Polarimeter

  • 摘要
  • 论文信息
  • 参考文献
  • 被引情况
  • PDF全文
分享:

摘要

同时偏振成像系统可获取动态物体的瞬态偏振特性,具有广泛的应用前景。然而各偏振探测通道存在空间和辐射响应差异,对准确建立仪器穆勒矩阵造成干扰。针对分束型同时偏振成像系统,分析了误差来源,提出了定标及预处理方法。通过成像非均匀性、辐射响应不一致性、检偏角度误差、瞬时视场像差的标定和校正,消除了偏振成像探测的系统误差。结果显示:经过定标和校准处理,各通道图像非均匀度平均降低了2.24%,辐射响应差异率绝对值平均降低了17.22%,偏振相对快轴方向平均纠正了1.71°,成像几何偏差平均纠正了1.87个像元。校正后,系统偏振度和偏振角测量误差分别降低0.47和32.84°。对室外场景进行测量实验,经过预处理正确解算斯托克斯参量,并通过偏振图像融合处理,突出了不同材质的物性差异。

Abstract

The simultaneous imaging polarimeter can obtain the transient polarization characteristics of moving objects, and it has a wide application prospect. However, the polarization detection channels differ in spatial and radiation response, which interferes with the accurate establishment of the instrument Muller matrix. The system error source is analyzed, and the calibration and preprocessing method is proposed for the amplitude divided simultaneous imaging polarimeter. The system error of polarization imaging detection is eliminated by the calibration and correction of non-uniformity of detectors, inconsistency of radiation response, deviation of polarizers oriented angles, and difference of instantaneous field of views. The results show that after the calibration and preprocessing, the CCD non-uniformity of every channel decreases by 2.24% on average, the absolute values of radiation response differences ratio decrease by 17.22% on average, the actual polarizer oriented angles are corrected by 1.71° on average, and the imagery pixel offsets are corrected by 1.87 pixel on average. After correction, the measurement error of polarization degree and polarization angle decrease by 0.47 and 32.84°, respectively. The outdoor scene is measured and tested, the Stokes parameters are calculated correctly after preprocessing, and the physical characteristics of different materials are highlighted after the polarization imaging fusion.

广告组1 - 空间光调制器+DMD
补充资料

中图分类号:O436

DOI:10.3788/AOS202040.2011002

所属栏目:成像系统

基金项目:国家自然科学基金;

收稿日期:2020-04-30

修改稿日期:2020-07-10

网络出版日期:2020-10-01

作者单位    点击查看

崔文煜:中国科学院安徽光学精密机械研究所通用光学定标与表征技术重点实验室, 安徽 合肥 230031
黄文娟:中国科学院安徽光学精密机械研究所通用光学定标与表征技术重点实验室, 安徽 合肥 230031中国科学技术大学, 安徽 合肥 230026
易维宁:中国科学院安徽光学精密机械研究所通用光学定标与表征技术重点实验室, 安徽 合肥 230031

联系人作者:易维宁(yiwn@aiofm.ac.cn)

备注:国家自然科学基金;

【1】Zhang Y J, Wang X, He S. Polarization properties of rough surfaces based on polarized bi-directional reflectance distribution function [J]. Acta Optica Sinica. 2018, 38(3): 0329002.
章延隽, 王霞, 贺思. 基于偏振双向反射分布函数的粗糙表面偏振特性 [J]. 光学学报. 2018, 38(3): 0329002.

【2】Tao Z, Liu J M, Zhang C W, et al. Compactpolarized spectrometer based on spatial modulation of polarization state [J]. Journal of Infrared and Millimeter Waves. 2016, 35(5): 557-564.
陶泽, 刘佳敏, 张传维, 等. 基于偏振态空间调制的紧凑型偏振光谱仪 [J]. 红外与毫米波学报. 2016, 35(5): 557-564.

【3】Wang J J, Liang L, Li S, et al. Correction and implementation of polarization-difference imaging model for underwater target [J]. Acta Optica Sinica. 2019, 39(11): 1111003.
汪杰君, 梁磊, 李树, 等. 水下目标偏振差分成像模型修正与实现 [J]. 光学学报. 2019, 39(11): 1111003.

【4】Ju H J, Liang J, Zhang W F, et al. Simultaneous, real-time, chromatic polarimetric imagingtechnology with full-polarization-state detection [J]. Journal of Infrared and Millimeter Waves. 2017, 36(6): 744-748.
巨海娟, 梁健, 张文飞, 等. 全偏振态同时探测实时彩色偏振成像技术 [J]. 红外与毫米波学报. 2017, 36(6): 744-748.

【5】Fan H M, Kang Q, Qiu Z W, et al. Polarization calibration for multi-spectral aperture-divided simultaneous detection system [J]. Acta Optica Sinica. 2017, 37(2): 0228001.
范慧敏, 康晴, 裘桢炜, 等. 多光谱分孔径同时探测系统偏振定标方法 [J]. 光学学报. 2017, 37(2): 0228001.

【6】Krishnan S. Calibration, properties, andapplications of the Division-of-amplitude photopolarimeter at 632.8 and 1523 nm [J]. Journal of the Optical Society of America A. 1992, 9(9): 1615-1622.Krishnan S. Calibration, properties, andapplications of the Division-of-amplitude photopolarimeter at 632.8 and 1523 nm [J]. Journal of the Optical Society of America A. 1992, 9(9): 1615-1622.

【7】Wang Y H, Zheng C L, Zhao Z T. Multi-point calibration method based on stokes ellipsometry system [J]. Chinese Journal of Lasers. 2012, 39(11): 1108013.
王勇辉, 郑春龙, 赵振堂. 基于斯托克斯椭偏测量系统的多点定标法 [J]. 中国激光. 2012, 39(11): 1108013.

【8】Song M X, Sun B, Sun X B, et al. Polarization calibration of airborne Muti-angle polarimetric radiometer [J]. Optics and Precision Engineering. 2012, 20(6): 1153-1158.
宋茂新, 孙斌, 孙晓兵, 等. 航空多角度偏振辐射计的偏振定标 [J]. 光学精密工程. 2012, 20(6): 1153-1158.

【9】Hou J F, Wang D G, Deng Y Y, et al. Nonlinear least-square fitting polarization calibration of Stokes ellipsometer [J]. Optics and Precision Engineering. 2013, 21(8): 1915-1922.
侯俊峰, 王东光, 邓元勇, 等. 斯托克斯椭偏仪的非线性最小二乘拟合偏振定标 [J]. 光学精密工程. 2013, 21(8): 1915-1922.

【10】Li S, Qiu Z W. Polarization orientation calibration of simultaneous imaging polarimeter [J]. Infrared and Laser Engineering. 2014, 43(12): 4100-4104.
李双, 裘桢炜. 同时偏振成像仪检偏方位校正研究 [J]. 红外与激光工程. 2014, 43(12): 4100-4104.

【11】Weng J W, Yuan Y L, Zheng X B, et al. Method for measuring response non-uniformity of polarization channels in directional polarization camera [J]. Acta Optica Sinica. 2020, 40(8): 0828001.
翁建文, 袁银麟, 郑小兵, 等. 多角度偏振成像仪偏振通道响应非一致性测量方法 [J]. 光学学报. 2020, 40(8): 0828001.

【12】Kang Q, Yuan Y L, Li J J, et al. Polarization calibration methods of channel-type polarization remote sensor [J]. Journal of Atmospheric and Environmental Optics. 2015, 10(4): 343-349.
康晴, 袁银麟, 李健军, 等. 通道式偏振遥感器偏振定标方法研究 [J]. 大气与环境光学学报. 2015, 10(4): 343-349.

引用该论文

Cui Wenyu,Huang Wenjuan,Yi Weining. Calibration and Preprocessing Method for Amplitude Divided Simultaneous Imaging Polarimeter[J]. Acta Optica Sinica, 2020, 40(20): 2011002

崔文煜,黄文娟,易维宁. 分束型同时偏振成像系统定标及预处理方法[J]. 光学学报, 2020, 40(20): 2011002

您的浏览器不支持PDF插件,请使用最新的(Chrome/Fire Fox等)浏览器.或者您还可以点击此处下载该论文PDF