红外与激光工程, 2018, 47 (2): 0222002, 网络出版: 2018-04-26   

微环差分光子生物传感器的传感性能

Sensing performance of micro-ring differential optical biosensor
作者单位
电子科技大学 光电信息学院, 四川 成都 610054
摘要
通过模拟仿真, 研究了基于绝缘衬底上的硅(Silicon-On-Insulator, SOI)的微环生物传感器的传感性能, 得出其体传感灵敏度为38.71 nm/RIU, 探测极限为1.8×10-3 RIU, Q值为2.22×104。基于该结构, 分析了噪声对传感器性能的影响, 包括光源噪声和温度噪声。为了降低噪声影响, 设计了具有参考和探测通道的双微环差分传感器, 通过差分运算扣除噪声引起的谐振波长漂移, 从而可以有效降低噪声对传感器探测结果的影响。通过数值模拟和计算, 其被探测物的折射率变化的相对误差减小了15.85%, 表明微环差分传感器可以有效降低噪声的影响, 对提高微环生物传感器的性能将有极大的促进作用。
Abstract
The sensing performance of micro-ring biosensor on Silicon-On-Insulator(SOI) was studied through simulation. The sensitivity of 38.71 nm/RIU, detection limit of 1.8×10-3 RIU and Q factor of 2.22×104 were achieved. The effects of noise on the sensor, including the light source noise and temperature noise, were then investigated. A dual micro-ring differential sensor with reference and probe channels was proposed, and the wavelength drift induced by the noises can be deducted to reduce the influence of noise by this differential operation. The relative error of the refractive index change was reduced by 15.85% through the calculation and numerical simulation, so the micro-ring differential biosensor can effectively reduce the influence of noise to enhance the sensing performance of the micro-ring biosensor.
参考文献

[1] 梁居发, 敬世美, 孟爱华, 等. 基于光纤布拉格光栅与长周期光栅并联的集成光学传感器[J]. 中国光学, 2016, 9(3): 329-334.

    Liang Jufa, Jing Shimei, Meng Aihua, et al. Integrated optical sensor based on a FBG in parallel with a LPG[J]. Chinese Optics, 2016, 9(3): 329-334. (in Chinese)

[2] 卢晓云, 薛晨阳, 王永华, 等. 毫米级氟化钙盘腔的加工与测试[J]. 红外与激光工程, 2015, 44(10): 3049-3054.

    Lu Xiaoyun, Xue Chenyang, Wang Yonghua, et al. Fabrication and test of millimeter-size CaF2 disk resonator[J]. Infrared and Laser Engineering, 2015, 44(10): 3049-3054. (in Chinese)

[3] Tomazio N B, Otuka A J G, Almeida G F B, et al. Femtosecond laser fabrication of high-Q whispering gallery mode microresonators via two-photon polymerization[J]. Journal of Polymer Science Part B: Polymer Physics, 2017, 55(7): 569-574.

[4] Wan H, Zhu H, Liu L, et al. Ultra-narrow-band optical filter based on whispery-gallery-mode hybrid-microsphere-cavity[C]//International Symposium on Optoelectronic Technology and Application, 2016: 1015311.

[5] 崔乃迪, 寇婕婷, 梁静秋, 等. 三环型波导微环谐振器无热化生物传感器[J]. 中国光学, 2014, 7(3): 428-434.

    Cui Naidi, Kou Jieting, Liang Jingqiu, et al. Athermal biosensor based on three waveguide micro-ring resonators[J]. Chinese Optics, 2014, 7(3): 428-434. (in Chinese)

[6] Wang H, Yuan L, Huang J, et al. Integrated microsphere whispering gallery mode probe for highly sensitive refractive index measurement[J]. Optical Engineering, 2016, 55(6): 067105.

[7] 徐俊杰. 小孔圆盘复合结构微腔谐振器的制备与研究[D]. 长春: 吉林大学, 2016.

    Xu Junjie. Fabrication and research of microdisk resonator with holes[D]. Changchun: Jilin University, 2016. (in Chinese)

[8] 应毓海. 新型的可调谐微环谐振器的设计[J]. 红外与激光工程, 2016, 45(6): 0620002.

    Ying Yuhai. Design of new kind of tunable micro ring resonator[J]. Infrared and Laser Engineering, 2016, 45(6): 0620002. (in Chinese)

[9] 赵健, 施芹, 夏国明, 等. 小型化硅微谐振式加速度计的实现与性能测试[J]. 光学 精密工程, 2016, 24(8): 1927-1933.

    Zhao Jian, Shi Qin, Xia Guoming, et al. Implementation and measurement of a miniaturized silicon resonant accelerometer[J]. Optics and Precision Engineering, 2016, 24(8): 1927-1933. (in Chinese)

[10] Sendowski J B. On-chip integrated label-free optical biosensing[D]. California: California Institute of Technology, 2013.

[11] Claes T, Molera J G, Vos K D, et al. Label-free biosensing with a slot-waveguide-based ring resonator in silicon on insulator[J]. IEEE Photonics Journal, 2009, 1(3): 197-204.

[12] Barrois C A. Integrated microring resonator sensor arrays for labs-on-chips[J]. Analytical & Bioanalytical Chemistry, 2012, 403(6): 1467-1475.

[13] Yalcin A, Popat K C, Aldridge L J C, et al. Optical sensing of biomolecules using microring resonators[J]. IEEE Journal of Selected Topics in Quantum Electronics, 2006, 12(1):148-155.

[14] 李超, 王永杰, 李芳. 基于F-P温控标准具的高稳定性FBG波长解调系统[J]. 红外与激光工程, 2017, 46(1): 0122002.

    Li Chao, Wang Yongjie, Li Fang. Highly stable FBG wavelength demodulation system based on F-P etalon with temperature control module[J]. Infrared and Laser Engineering, 2017, 46(1): 0122002. (in Chinese)

[15] Lee J M, Kim D J, Ahn H. Temperature dependence of silicon nanophotonic ring resonator with a polymeric overlayer[J]. Journal of Lightwave Technology, 2007, 25(8): 2236-2243.

[16] Wang C T, Wang C Y, Yu J H, et al. Highly sensitive optical temperature sensor based on a SiN micro-ring resonator with liquid crystal cladding[J]. Optics Express, 2016, 24(2): 1002-1007.

管磊, 王卓然, 袁国慧, 陈昱任, 董礼, 彭真明. 微环差分光子生物传感器的传感性能[J]. 红外与激光工程, 2018, 47(2): 0222002. Guan Lei, Wang Zhuoran, Yuan Guohui, Chen Yuren, Dong Li, Peng Zhenming. Sensing performance of micro-ring differential optical biosensor[J]. Infrared and Laser Engineering, 2018, 47(2): 0222002.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote