VOCs在线监测气体吸收池的传输效率优化设计
王君博, 王昕, 尉昊赟, 李岩. VOCs在线监测气体吸收池的传输效率优化设计[J]. 激光技术, 2017, 41(2): 163.
WANG Junbo, WANG Xin, WEI Haoyun, LI Yan. Optimization design of transmission for on-line VOCs sensing gas cell[J]. Laser Technology, 2017, 41(2): 163.
[1] QIANG W, GANG Z, QI Z. Status and needs research for on-line monitoring of VOCs emissions from stationary sources[J]. Environmental Science, 2013, 34(12): 2-3.
[2] MEI J, LAN Z, QIAN L X. Definition and control indicators of volatile organic compounds in China[J].Environmental Science, 2015, 36(9): 3522-3532.
[3] BERNSTEIN H J, HERZBERG G. Rotation-vibration spectra of diatomic and simple polyatomic molecules with long absorbing paths[J]. Journal of Chemical Physics, 1948,16(1): 30-39.
[4] XIN C K. Trace gas detection by miniature multi-pass differential optical absorption spectroscopy [D].Beijing: Tsinghua University,2010: 36-45(in Chinese).
[5] WHITE J U. Very long optical paths in air[J].Journal of the Optical Society of America,1976, 66(5): 411-416.
[6] HERRIOT D R, SCHULTE H J. Folded optical delay lines [J]. Applied Optics, 1965, 4(8): 883-889.
[7] RUI W. Research on the long-path cell of infrared spectrum instrument [D]. Tianjin: Tianjin University, 2006: 25-26(in Chinese).
[8] WEI Z. Studying of air quality monitoring system based on FTIR [D]. Tianjin: Tianjin University, 2006: 44-45(in Chinese).
[9] PENG A Y. Design of the optical structure of the mid-infrared gas sensing system by using the TracePro [J]. Laser & Infrared, 2009, 39(11): 1198-1200(in Chinese).
[10] HUANG D S. Design of micro-displacement mechanism and analyzing of accuracy in a long optical path air sumulan cell[J]. Journal of Changchun Institute of Optics and Fine Mechanics, 1993, 16(4): 45-48(in Chinese).
[11] HUA H Z. Effect of nonuni form temperature distribution in gas cell on gas absorption transmissivity [J]. Transactions of Beijing Institute of Technology, 2011, 31(7): 865-866(in Chinese).
[12] BARTLOME R, BAER M, SIGRIST M W. High-temperature multi-pass cell for infrared spectroscopy of heated gases and vapors[J]. Review of Scientific Instruments, 2006, 78(78): 1-2.
[13] HUA X, ZHONG D F, JIE G T. High sensitive detection of carbon monoxide based on novel multi-pass cell[J]. Acta Optica Sinica, 2010, 30(9): 2597-2598(in Chinese).
[14] MONDELAIN D, PEYRET C C, MANTZ A W, et al. Performance of a Herriott cell, designed for variable temperatures between 296 and 20K [J]. Journal of Molecular Spectroscopy, 2007, 24 (1): 18-25.
[15] YAO X. The design of several special optical systems and finite element analysis [D]. Beijing: Beijing Institute of Technology,2015: 24-26(in Chinese).
王君博, 王昕, 尉昊赟, 李岩. VOCs在线监测气体吸收池的传输效率优化设计[J]. 激光技术, 2017, 41(2): 163. WANG Junbo, WANG Xin, WEI Haoyun, LI Yan. Optimization design of transmission for on-line VOCs sensing gas cell[J]. Laser Technology, 2017, 41(2): 163.