强激光与粒子束, 2012, 24 (1): 119, 网络出版: 2012-02-14   

双板电极条纹变像管设计

Bilamellar type streak tube design
作者单位
1 电子科技大学 物理电子学院, 成都 610054
2 中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
摘要
为满足惯性约束聚变(ICF)实验等离子体诊断中对X射线条纹相机大动态和高时空分辨能力的需求, 设计了一款利用板状电极对加电四极透镜聚焦方式的变像管。此款变像管最主要的特点为时空方向聚焦方式不同, 在时间方向上采用两对平板电极聚焦电子, 而在空间方向上采用电四极透镜对电子进行聚焦, 其空间分辨能力在阴极边缘处达到了40 lp/mm, 时间分辨能力在10 ps左右, 阴极有效长度为20 mm。由于变像管采用时空方向分别聚焦方式, 相对传统轴对称管型来说, 电子不会聚焦成点, 空间电荷效应更弱, 所以具有大动态能力。
Abstract
In ICF experiments, high dynamic range, high temporal and spatial resolution X-ray streak camera is a necessary diagnosis tool. To meet this requirement, a streak tube which uses bilamellar electrode lens and quadrupolar lens to focus electrons has been designed. This tube uses different ways to focus electrons in temporal axis and spatial axis. In temporal axis, it uses two bilamellar electrode lenses to focus electrons and in spatial axis it uses quadrupolar lens which can reduce image aberration effectively. The spatial resolution of this tube reaches 40 lp/mm even at the edge of photocathode, the temporal resolution is about 10 ps and the effective length of photocathode is 20 mm. Using different focusing ways in temporal and spatial directions, the tube will not focus electrons to a small spot, compared with conventional rotary and symmetric tubes, and thus its space charge effect is much weaker, and dynamic range is much larger.
参考文献

[1] 项志遴, 俞昌旋.高温等离子体诊断技术上册[M].上海:上海科学技术出版社, 1982:56-99.(Xiang Zhilin, Yu Changxuan. Diagnosis technology of high temperature plasma. Shanghai: Shanghai Science and Technology Press, 1982:56-99)

[2] Sibbett W, Niu H, Baggs M R. Photochron IV subpicosecond streak image tube[J]. Rev Sci Instrum, 1982, 53(6):758-761.

[3] Inagaki Y, Takeshita T, Kinoshita K, et al. High dynamic range streak tube[C]//Proc of SPIE. 2001, 4183:249-254.

[4] Schirmann D, Mens A, Sauneuf R, et al. Performance of the ultra fast streak camera C850X[C]//Proc of SPIE. 1992, 1757:8-18.

[5] Bourgade J L, Troussel P. A versatile high-resolution X-ray imager (HRX) for laser-plasma experiments on OMEGA[J]. Rev Sci Instrum, 2008, 79:1-5.

[6] Murnane M M, Kapteyn H C, Falcone R W. X-ray streak camera with 2 ps response[J]. Appl Phys Lett, 1990, 56(20):1948-1950.

[7] Wiedwald J D, Lerche R A. Streak camera dynamic range optimization[C]//Proc of SPIE.1987, 832: 275-282.

[8] Lerche R A, McDonald J W, Griffith R L, et al. Preliminary performance measurements for a streak camera with a large-format direct-coupled CCD readout[J]. Rev Sci Instrum, 2004, 75(10):4042-4044.

[9] 廖华, 杨勤劳, 张劲松, 等.大动态长狭缝相机系统[J]. 强激光与粒子束, 2008, 20(9):1558-1562.(Liao Hua, Yang Qinlao, Zhang Jinsong, et al. High dynamic range streak camera system with long slit. High Power Laser and Particle Beams, 2008, 20(9):1558-1562)

李晋, 刘慎业, 陈韬, 胡昕, 肖绍球. 双板电极条纹变像管设计[J]. 强激光与粒子束, 2012, 24(1): 119. Li Jin, Liu Shenye, Chen Tao, Hu Xin, Xiao Shaoqiu. Bilamellar type streak tube design[J]. High Power Laser and Particle Beams, 2012, 24(1): 119.

本文已被 3 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!