强激光与粒子束, 2020, 32 (2): 025018, 网络出版: 2020-03-18   

1 MV X光机系统可靠性实验研究

Experimental research on reliability of 1 MV X-ray system for radiography
作者单位
中国工程物理研究院 流体物理研究所,脉冲功率科学与技术重点实验室,四川 绵阳 621900
图 & 表

图 1. Schematic illustration of the 1 MV X-ray system

Fig. 1. Schematic illustration of the 1 MV X-ray system

下载图片 查看原文

图 2. Photo of the 1 MV X-ray system

Fig. 2. Photo of the 1 MV X-ray system

下载图片 查看原文

图 3. Experimental results of switch jitter开关导通时延统计图

Fig. 3. Experimental results of switch jitter开关导通时延统计图

下载图片 查看原文

图 4. Experimental results of switch self-breakdown voltage开关自击穿电压统计图

Fig. 4. Experimental results of switch self-breakdown voltage开关自击穿电压统计图

下载图片 查看原文

图 5. Photo of the flashover on insulator真空室绝缘隔板沿面闪络图片

Fig. 5. Photo of the flashover on insulator真空室绝缘隔板沿面闪络图片

下载图片 查看原文

图 6. Time jitter of the 1 MV X-ray system系统出光延时时间分布图

Fig. 6. Time jitter of the 1 MV X-ray system系统出光延时时间分布图

下载图片 查看原文

图 7. Dose at 1 m right in front of the 1 MV X-ray system系统输出剂量分布图

Fig. 7. Dose at 1 m right in front of the 1 MV X-ray system系统输出剂量分布图

下载图片 查看原文

表 1设计参数表

Table1. Design parameters

geometrical parameterselectrical parameters
Marx generatordimensions:~2 970 mm×1 690 mm×1 000 mm; switch gap:23 mm±0.2 mm 9 stage; capacitor:100 kV/0.4 μF; charge voltage: ±58 kV; number of capacitor:18; k≈0.6
pulse forming lineinner diameter of the outer conductor:614 mm; outer diameter of the inner conductor:292 mm; L≈1 m equivalent capacitor:6 nF; impedance:5 Ω; k≈0.6
oil switchswitch gap≈26 mm/
pulse transmission lineinner diameter of the outer conductor:614 mm; outer diameter of the inner conductor:76 mm; L≈1.34 m equivalent capacitor:2.9 nF; impedance:14 Ω; k≈0.6
rod-pinch diodediameter of the graphite cathode hole:12 mm; thickness:3 mm; diameter of the tungsten anode rod:1.5 mm; outer dimension~11 mmdesign impedance:40 Ω
oil transmission lineinner diameter of the outer conductor:320 mm; outer diameter of the inner conductor:102 mm; L≈2 m impedance:45 Ω; k≈0.6

查看原文

表 2可靠性措施表

Table2. Measurements of the reliability

\failure modeaction
hardware designoil transmission line,pulse transforming line and pulse transmission line electric breakdownconservative electrical stress design, k≈0.6
Marx generation electrical breakdownconservative Marx generation electrical stress design
Marx generation trigger reliabilitypulse transformer trigger mode,output voltage up to double capacitor charge voltage,rise time less than 70 ns
diode insulator and structure coherencerobust electrode design and vacuum system design,assistant system
procedural designinspector before testspecific parameters of oil,water,vacuum and diode;special check table
operation in testspecial operation order and time
operation after testspecific test recorder and analysis,find hidden failure

查看原文

表 31 MV X光机系统与Cygnus工作情况对比表

Table3. Performance contrast of the 1 MV X-ray system and Cygnus systems

working shotsfailure shots
Cygnus11642
Cygnus21714
1 MV X-ray system2410

查看原文

马成刚, 李洪涛, 邓明海, 曹宁翔, 莫腾富, 王晓, 张志强. 1 MV X光机系统可靠性实验研究[J]. 强激光与粒子束, 2020, 32(2): 025018. Chenggang Ma, Hongtao Li, Minghai Deng, Ningxiang Cao, Tengfu Mo, Xiao Wang, Zhiqiang Zhang. Experimental research on reliability of 1 MV X-ray system for radiography[J]. High Power Laser and Particle Beams, 2020, 32(2): 025018.