强激光与粒子束, 2009, 21 (5): 755, 网络出版: 2009-11-24   

软X射线皮秒分幅相机的增益压窄效应

Gain narrowing effect of soft X-ray picoseconds framing camera
作者单位
1 中国科学院 西安光学精密机械研究所 瞬态光学与光子技术国家重点实验室,西安 710119
2 中国科学院 西安光学精密机械研究所 超快诊断技术重点实验室,西安 710119
摘要
高速行波选通的X射线皮秒分幅相机的时间分辨率受皮秒选通脉冲的宽度和幅值的非线性关系直接影响。针对微通道板(MCP)行波选通皮秒分幅相机中的“增益压窄效应”,在高斯型皮秒选通电脉冲作用下,通过计算MCP分幅管的时间分辨率和对增益压窄效应的分析,得到MCP皮秒选通分幅管的增益压窄指数约为10.0,分幅管的时间分辨率约为选通脉冲脉宽的1/3.16。并在脉冲参数(250 ps,-1 100 V)和(220 ps,-900 V)下进行了分幅相机时间分辨率理论计算和实验测试,分别得到了理论时间分辨率为78.8 ps和67.6 ps,相机实验时间分辨率为76.4 ps 和66.5 ps的结果。
Abstract
Temporal resolution of a soft X-ray picoseconds framing camera(XPFC) based on gated micro-channel plate (MCP) depends strong-nonlinearly on parameters of gating pulse (width,amplitude) and is much shorter than the gating pulse width,which the so-called “gain narrowing effect”.The temporal resolution and the gain narrowing effect exponent of the XPFC being gated by picoseconds electric pulse are computed and analyzed.So the estimated gain narrowing effect exponent is about 100 and the temporal resolution of the framing camera is about 1/3.16 times the width of the gating pulse.The simulations and experiments on the temporal resolution of the XPFC gated respectively by the gating pulse with (250 ps,-1 100 V) and (220 ps,-900 V) are presented.Simulation result of 78.8 ps and experimental result of 76.4 ps with the gating pulse (250 ps,-1 100 V),and simulation result of 67.6 ps and experimental result of 66.5 ps with the gating pulse (220 ps,-900 V) are obtained.
参考文献

[1] Bradley D K,Bell P M,Kilkenny J D,et al.High-speed gated X-ray imaging for ICF target experiment[J].Rev Sci Instrum,1992,63(10):4813-4817.

[2] Ze F,Kauffman R L,Kilkenny J D,et al.A new multichannel soft X-ray framing camera for fusion experiments[J].Rev Sci Instrum,1992,63(10):5124-5126.

[3] Katayama M,Nakai M,Yamanaka T,et al.Multiframe X-ray imaging system for temporally and spatially resolved measurement of imploding inertial confinement fusion targets[J].Rev Sci Instrum,1991,62(1):124-129.

[4] 杨家敏,丁耀南,郑志坚,等.时空分辨软X射线谱诊断技术研究[J].物理学报,2003,52(6):1427-1431.( Yang Jiamin,Ding Yaonan,Zheng Zhijian,et al.Diagnostic technology of time-and space-resolved soft-X-ray spectra.Acta Physica Sinica,2003,52(6):1427-1432)

[5] 陈进川,许泽平,夏广新,等.皮秒分幅相机在Z 箍缩实验光谱测量中的应用[J].强激光与粒子束,2008,20(1):71-75.(Chen Jinchuan,Xu Zeping,Xia Guangxin,et al.Exploratory research of spectral diagnosis on Z-pinch plasmas with picoseconds frame camera.High Power Laser and Particle Beams,2008,20(1):71-74)

[6] 常增虎,山冰,刘秀琴,等.微通道板选通X射线皮秒分幅相机[J].光子学报,1995,24(6):501-508.(Chang Zenghu,Shan Bing,Liu Xiuqin,et al.Picosecond X-ray framing camera using gated MCP.Acta Photonic Sinica,1995,24(6):501-508)

[7] Burton L H,Jerel A S.0.1-10-keV X-ray-induced electron emissions from solids-models and secondary electron measurements[J].Journal of Applied Physics,1977,48(5):1852-1866.

[8] Eberhardt E H.Gain model for microchannel plates[J].Appl Opt,1979,18(9):1418-1423.

[9] Bell P M,Hammel B A,Bradley D K,et al.Modeling and measurements of sub 100 ps gating with microchannel plates[C]//Proc of SPIE.1989,1155:415-521.

[10] 方开泰.均匀设计与均匀设计表 [M].北京:科学出版社,1994:33-77.(Fang Kaitai. Uniform designs and uniform designs charts. Beijing:Science Press,1994:33-77)

[11] 杨文正,侯洵,白永林,等.微通道板选通X射线皮秒分幅相机曝光时间的均匀设计[J].光子学报,2008,37(3):439-443.(Yang Wenzheng,Hou Xun,Bai Yonglin,et al.Uniform design method of the exposure time of X-ray picoseconds framing camera with gated microchannel plate.Acta Photonic Sinica,2008,37(3):439-443)

杨文正, 白永林, 秦君军, 赵军平, 白晓红, 刘百玉. 软X射线皮秒分幅相机的增益压窄效应[J]. 强激光与粒子束, 2009, 21(5): 755. Yang Wenzheng, Bai Yonglin, Qin Junjun, Zhao Junping, Bai Xiaohong, Liu Baiyu. Gain narrowing effect of soft X-ray picoseconds framing camera[J]. High Power Laser and Particle Beams, 2009, 21(5): 755.