Journal of Innovative Optical Health Sciences, 2017, 10 (3): 1650051, Published Online: Dec. 27, 2018  

Deep tissue near-infrared imaging for vascular network analysis

Author Affiliations
Department of Electrical & Electronics Engineering, Faculty of Engineering, Ege University Bornova, Izmir, Turkey, 35100
Abstract
Subcutaneous vein network plays important roles to maintain microcirculation that is related to some diagnostic aspects. Despite developments of optical imaging technologies, still the di±culties about deep skin vascular imaging have been continued. On the other hand, since hemoglobin concentration of human blood has key role in the veins imaging by optical manner, the used wavelength in vascular imaging, must be chosen considering absorption of hemoglobin. In this research, we constructed a near infrared (NIR) light source because of lower absorption of hemoglobin in this optical region. To obtain vascular image, reflectance geometry was used. Next, from recorded images, vascular network analysis, such as calculation of width of vascular of interest and complexity of selected region were implemented. By comparing with other modalities, we observed that proposed imaging system has great advantages including nonionized radiation, moderate penetration depth of 0.5–3mm and diameter of 1mm, cost-effective and algorithmic simplicity for analysis.
References

[1] L. Zhanjun, Z. Yuanwei, W. Xiang, W. Xiaoqiong, M. Rohit, Z. Hongwu, H. Gang , “In vivo repeatedly charging near-infrared-emitting mesoporous SiO2/ZnCa2O4:Cr3 ++ persistent luminescence nanocomposites,” Adv. Sci. 1500001 (2), 1–6 (2015).

[2] L. Zhanjun, Z. Yuanwei, L. Hieu, Z. Richard, E. Ghida, W. Yuzou, H. Gang , “Upconevrting NIR photons for bioimaging,” Nanomaterials 5, 2148–2168 (2015).

[3] K. Phipps, A. Modic, M. A. O’Riordan, M. Walsh , “A randomized trial of the vein wiever versus Standard technique for placement of peripherally inserted central catheters (PICCs) in neonates,” J. Perinatol. 32 (7), 1–4 (2011). ISI,

[4] D. Yaping, B. Xu, F. Tao, C. Miao, L. Feng, Z. Yan, W. Qiangbin , “Near-infrared photoluminescent Ag2S quantum dots from a single source precursor,” J. Am. Chem. Soc. 132 (5), 1470–1471 (2010).

[5] V. Krasimir, M. Agnieszka, L. H. Andrew, C. Joseph, H. V. Nicolas, D. S. Rob , “Creating gradients of two proteins by differential passive absorption onto a PEG-density gradient,” Biometarials 31, 392–397 (2010).

[6] H. Guosong, C. L. Jerry, T. R. Joshua, R. Uwe, X. Liming, F. H. Ngan, P. C. John, D. Hongjie , “Multifunctional in vivo vascular imaging using near infrared II fluorescence,” Nat. Med. 18, 1841–1846 (2012).

[7] H. D. Zeman assignee, Contrast enhancing illuminator, US Patent 5,969,754 Oct 19 (1999).

[8] L. Wang, G. Leedham, S. Y. Cho , “Infrared imaging of hand vein patterns for biometric purposes,” IET Comput. Vis. 1 (3–4), 113–122 (2007).

[9] Y. Ding, D. Zhuang, K. Wang , “A study of hand vein recognotion method,” Proc. IEEE Int. Conf. Mechatronics Automation, Vol. 4, pp. 2106–2110 (2005).

[10] K. Seker, Design of Optical Imaging Based Vascular Evolution Monitoring System for Superficial Tumor Medication, Master thesis, Ege University, Izmir/TURKEY (2015).

[11] T. Myllyla, A. Popov, V. Korhonen, A. Bykov, M. Kinnunen , “Optical sending of a pulsating liquid in a brain-mimicking phantom,” Proc. SPIE 8799, 87990X (2013). Crossref,

[12] C. Chen, F. Klampfl, R. Kanawade, M. Riemann, C. Knipfer, F. Stelzle, M. Schmidt , “Recovering the superficial Microvascular pattern via diffuse reflection imaging: Phantom validation,” Bio. Med. Eng. Online 14, 87 (2015).

[13] K. T. Arun, A. J. Farouc , “Intravascular near-infrared fluorescence molecular imaging of atherosclerosis,” Am. J. Nucl. Mol. Imag. 3 (3), 217–231 (2013).

[14] B. Zhu, E. M. Sevick-Muraca , “A review of performance of near-infrared fluorescence imaging devices used in clinical studies,” Br. J. Radiol 88, 20140457 (2015).

[15] S. Felix, K. Stefan, J. M. Andreas, Z. Rapheal, M. P. Juan, W. Ursula, W. Martin , “A review on continuous wave functional near-infrared spectroscopy and imaging instrumentation and methodology,” Neurolmage 85, 6–27 (2014).

[16] J. Simon, Z. Borut, “An innovative approach to near-infrared spectroscopy using a standard mobile device and its clinical application in the real-time visualization of peripheral veins,” 14, 100 (2014).

[17] A. H. Holly , “A biomedical device for improve pediatric vascular access seccess,” Pediatr. Nurs. 36 (5), 259–263 (2010).

[18] K. M. Roberto, D. Z. Herbert, H. D. Flavio, K. Rodrigo, R. Eduardo, L. Gunnar, V. Carlos , “Vein imaging: A new method of near infrared imaging, where a processed image is projected onto the skin fort he enhancement of vein treatment,” Dermatol. Surg. 32, 1031–1038 (2006). ISI,

[19] Y. Aycan, A. Lale, S. Bulent , “Hand vein biometry based on geometry and appearance methods,” IET Comput. Vis. 5 (6), 398–406 (2011).

[20] S. W. Maciej, P. P. Alexey, V. B. Alexander, K. Matti, J.-S. Malgorzata, V. T. Valery , “Measurements of fundemental properties of homogeneous tissue phantoms,” J. Biomed. Opt. 20 (4), 045004 (2015).

[21] Oregon Medical Laser Center, Oregon Health & Science University, Portland, Oregon, USA, http://omlc.org/ (2016).

[22] M. S. Neethu, V. K. Jayasree , “Contrast limited adaptive histogram equalization for qualitative enhancement of myocardial perfusion images,” Engineering 5, 326–331 (2013). Crossref,

[23] M. S. Pizer, D. A. John, R. P. John, D. S. Hal , Adaptive Histogram Equalization for Automatic Contrast Enhancement of Medical Images, North Carolina University (1986). Crossref,

[24] N. Fangyan, G. Chao, G. Yongcai, G. Min , “Two-dimentional minimum local cross-entropy thresholding based on co-occurance matrix,” Comput. Electr. Eng. 37, 757–767 (2011).

[25] R. C. Gonzalez, R. E. Woods , Digital Image Processing, Prentice-Hall, New Jersey (2002).

[26] S. M. White, C. S. George, B. Choi , Automated computation of functional vascular density using laser speckle imaging in a rodent window chamber model, Microvasc. Res. 82 (1), 92–95 (2011).

[27] S. Paul, K. Patrick, B. John , Improvement in the visualization of superficial arm veins being evaluated for access and bypass, 17th Annual Meeting of the American Venous Forum, San Diego, Calif (2005).

Kübra Seker, Mehmet Engin. Deep tissue near-infrared imaging for vascular network analysis[J]. Journal of Innovative Optical Health Sciences, 2017, 10(3): 1650051.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!