光学学报, 2013, 33 (4): 0411002, 网络出版: 2013-02-26  

用阶跃法测量光声成像系统的点扩展函数

Measurement of the Point Spread Function of a Photoacoustic Imaging System using Step Method
作者单位
1 佛山科学技术学院电子与信息工程学院, 广东 佛山 52800
2 佛山科学技术学院理学院, 广东 佛山 52800
摘要
从理论上证明了光声成像系统的点扩展函数是边缘响应函数的一阶导数,提出了用阶跃法测量光声成像系统的点扩展函数,用染色琼脂对本方法进行了实验验证,理论计算结果和实验测量数据有很好的一致性,为复杂光声成像系统提供了一种简单实用的点扩展函数测量方法。
Abstract
We theoretically prove that the point spread function (PSF) of a photoacoustic imaging system is the first derivative of the edge response function, and a step method for measurement of the photoacoustic PSF is proposed. The proposed method is experimentally verified using dyed agarose gel phantom, and the results of theoretical calculations and experimental measurement are in good agreement. The method provides a simple and practical way to measure the PSF of a complex photoacoustic imaging system.
参考文献

[1] L. V. Wang. Multiscale photoacoustic microscopy and computed tomography [J]. Nature Photonics, 2009, 3(9): 503~509

[2] Lihong V. Wang, Song Hu. Photoacoustic tomography: in vivo imaging from organelles to organs [J]. Science, 2012, 335(6075): 1458~1462

[3] H. F. Zhang, K. Maslov, G. Stoica et al.. Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging [J]. Nature Biotechnology, 2006, 24(7): 848~851

[4] S. S. Oladipupo, S. Hu, A. C. Santeford et al.. Conditional HIF-1 induction produces multistage neovascularization with stage-specific sensitivity to VEGFR inhibitors and myeloid cell independence [J]. Blood, 2011, 117(15): 4142~4153

[5] R. O. Esenaliev, A. A. Karabutov, A. A. Oraevsky. Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors[J]. IEEE J. Sel. Top. Quantum Electron., 1999, 5(4): 981~988

[6] C. Kim, T. N. Erpelding, L. Jankovic et al.. Deeply penetrating in vivo photoacoustic imaging using a clinical ultrasound array system [J]. Biomedical Optics Express, 2010, 1(1): 278~284

[7] R. A. Kruger, D. R. Reinecke, G. A. Kruger. Thermoacoustic computed tomographytechnical considerations [J]. Med. Phys., 1999, 26(9): 1832~1837

[8] K. Maslov, H. F. Zhang, S. Hu et al.. Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries [J]. Opt. Lett., 2008, 33(9): 929~931

[9] S. Hu, K. Maslov, L. V. Wang. Second-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed [J]. Opt. Lett., 2011, 36(7): 1134~1136

[10] K. Maslov, M. Sivaramakrishnan, H. F. Zhang et al.. Technical considerations in quantitative blood oxygenation measurement using photoacoustic microscopy in vivo [C]. SPIE, 2006, 6086: 60860R

[11] X. Wang, X. Xie, G. Ku et al.. Noninvasive imaging of hemoglobin concentration and oxygenation in the rat brain using high-resolution photoacoustic imaging [J]. J. Biomed. Opt., 2006, 11(2): 024015

[12] J. Laufer, C. Elwell, D. Delpy et al.. Absolute measurements of local chromophore concentrations using pulsed photoacoustic spectroscopy [C]. SPIE, 2006, 6086: 60861J

[13] Jan Laufer, Dave Delpy, Clare Elwell et al.. Quantitative spatially resolved measurement of tissue chromophore concentrations using photoacoustic spectroscopy: application to the measurement of blood oxygenation and haemoglobin concentration [J]. Phys. Med. Biol., 2007, 52(1): 141~168

[14] 王毅, 周红仙. 检测参数对脉冲光声法测量绝对吸收系数准确性的影响[J]. 光学学报, 2009, 29(12): 3391~3394

    Wang Yi, Zhou Hongxian. Theoretical analysis of the influence of measurement parameters on the measurement accuracy of optical absorption coefficient with pulsed photoacoustic method [J]. Acta Optica Sinica, 2009, 29(12): 3391~3394

[15] D. W. Yang, D. Xing, S. H. Yang et al.. Fast full-view photoacoustic imaging by combined scanning with a linear transducer array [J]. Opt. Express, 2007, 15(23): 15566~15575

[16] Zhanxu Chen, Zhilie Tang, Wei Wan. Photoacoustic tomography imaging based on a 4f acoustic lens imaging system [J]. Opt. Express, 2007, 15(8): 4966~4976

[17] 魏亚东, 吴云霞, 张志坚. 声透镜对多层样品的光声层析成像[J]. 光学学报, 2012, 32(6): 0611002

    Wei Yadong, Wu Yunxia, Zhang Zhijian. Photoacoustic tomography of multi-layer sample using acoustic lens [J]. Acta Optica Sinica, 2012, 32(6): 06611002

[18] Yi Wang, Chunhui Li, Ruikang K. Wang. Noncontact photoacoustic imaging achieved by using a low-coherence interferometer as the acoustic detector [J]. Opt. Lett., 2011, 36(20): 3975~3977

[19] Yi Wang, Da Xing, Yaguang Zeng et al.. Photoacoustic imaging with deconvolution algorithm [J]. Phys. Med. Biol., 2004, 49(14): 3117~3124

[20] Yi Wang, Ruikang Wang. Photoacoustic recovery of an absolute optical absorption coefficient with an exact solution of a wave equation [J]. Phys. Med. Biol., 2008, 53(21): 6167~6177

周红仙, 周有平, 王毅. 用阶跃法测量光声成像系统的点扩展函数[J]. 光学学报, 2013, 33(4): 0411002. Zhou Hongxian, Zhou Youping, Wang Yi. Measurement of the Point Spread Function of a Photoacoustic Imaging System using Step Method[J]. Acta Optica Sinica, 2013, 33(4): 0411002.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!