萨伐尔偏光镜横向剪切量和光程差的精确计算
[1] Zhang Chunmin, Xiangli Bin, Zhao Baochang et al.. The latest developments of technique of interference imaging spectrometer[J]. Opt. Technol., 2000, 26(3): 232~234 (in Chinese)
张淳民,相里斌,赵葆常 等. 干涉成像光谱技术的新发展[J]. 光学技术, 2000, 26(3): 232~234
[2] Zhang Chunmin, Yang Jianfeng, Yuan Xinjing et al.. Research progress of polarization interference image spectroscopy[J]. Optoelectronics·Laser, 2000, 11(4): 444~448 (in Chinese)
张淳民,杨建峰,原新晶 等. 偏振干涉成像光谱技术研究进展[J]. 光电子·激光, 2000, 11(4): 444~448
[3] . Bruce Rafert, R. Glenn Sellar, Joel H. Blatt. Monolithic Fourier transform imaging spectrometer[J]. Appl. Opt., 1995, 34(31): 7228-7230.
[4] . Haydew. Smith, Philip D. Hammer. Digital array scanned interferometer: sensors and results[J]. Appl. Opt., 1996, 35(16): 2902-2908.
[5] Chunmin Zhang, Bin Xiangli, BaoChang Zhao. Static polarization interference imaging spectrometer (SPIIS)[C]. Proc. SPIE, 2000, 4087: 957~961
[6] Chunmin Zhang, Bin Xiangli, Baochang Zhao et al.. A static polarization imaging spectrometer base on Savart polariscope[J]. Opt. Commun., 2002, 203(1~2): 21~26
[7] . Analysis of the modulation depth affected by the polarization orientation in polarization interference imaging spectrometer[J]. Opt. Commun., 2003, 227: 221-225.
[8] . . Principle and modulation depth analysis of static larger field of view polarized interference imaging spectrometer[J]. J. Xi′an Jiaotong University, 2000, 34(6): 93-97.
[9] . Permissible deviations of the polarization orientation in the polarization imaging spectrometer[J]. J. Opt. A: Pure Appl. Opt., 2004, 6: 815-817.
[10] . Wide-field-of-view polarization interference imaging spectrometer[J]. Appl. Opt., 2004, 43(33): 6090-6094.
[12] . J. Padgett, A. R. Harvey. A static Fourier-transform spectrometer based on Wollaston prisms[J]. Rev. Sci. Instrum., 1995, 66(4): 2807-2811.
[13] . Courtial, B. A. Patterson, A. R. Harvey et al.. Design of a static Fourier-transform spectrometer with increased field of view[J]. Appl. Opt., 1996, 35(34): 6698-6702.
[14] . Exact calculation of the optical path difference and description of a new birefringent interferometer[J]. Opt. Engng., 1999, 38(6): 983-990.
[15] . Multichanel Fourier transform infrared spectrometer[J]. Appl. Opt., 1992, 31(28): 6096-6101.
[17] . Montarou, Thomas K. Gaylord. Analysis and design of modified Wollaston prisms[J]. Appl. Opt., 1999, 38(31): 6604-6616.
[18] M. Francon, S. Mallick. Polarization Interferometers[M]. New York: Wiley Interscience, 1971. 22~23, 136~146
[19] Li Jiaze, Zhu Baolian, Wei Guanghui. Crystal Optics[M]. Beijing: Beijing Institute of Technology Press, 1989. 107~114 (in Chinese)
李家泽,朱宝亮,魏光辉. 晶体光学[M]. 北京: 北京理工大学出版社, 1989. 107~114
[21] Xie Jianping, Wang Junmei, Fang Hui et al.. The walkoff effect of o, e light in birefringent filter[J]. Chin. J. Quantum Electronics, 1997, 14(4): 294298 (in Chinese)
谢建平,王峻梅,方晖 等. 双折射调谐器中o、e光的走离效应[J]. 量子电子学报, 1997, 14(4): 294~298
吴磊, 张淳民, 袁艳, 赵葆常. 萨伐尔偏光镜横向剪切量和光程差的精确计算[J]. 光学学报, 2005, 25(7): 885. 吴磊, 张淳民, 袁艳, 赵葆常. Exact Calculation of the Lateral Displacement and Optical Path Difference of Savart Polariscopes[J]. Acta Optica Sinica, 2005, 25(7): 885.