强激光与粒子束, 2016, 28 (11): 113001, 网络出版: 2016-12-26  

新型全吸收式高功率微波能量计

New type of high power energy calorimeter with full absorption
作者单位
中国工程物理研究院 计量测试中心, 四川 绵阳 621900
摘要
为解决高功率微波源传输线内能量的测量, 研制了一种全吸收式液体高功率微波能量计。能量计采用乙醇、去离子水等混合液作为吸收液, 吸收液吸收微波后体积膨胀, 探测器内的液面升高, 通过控制系统得到液面升高引起的电压变化值, 从而得到被测能量的大小。该套能量计具有结构简单、测量准确度高等特点, 经过实验, 测得能量计端口的电压反射系数小于-20 dB, 具有较好的匹配性, 能够开展10~600 J能量的测量, 5次测量结果标准偏差优于3%, 可满足高功率微波源传输线内或空间辐射能量的测量。
Abstract
To measure the energy within the transmission line of the high power microwave source, liquid absorption energy calorimeter with full absorption is developed. The mixture of ethanol and deionized water is used as absorbing liquid, the liquid level of the detector rises when the microwave energy is absorbed, and it is detected by the control system as the voltage variation, thus the microwave energy is accurately measured. The structure of the energy calorimeter is simple and has high accuracy. Measurements show that the reflection coefficient of the energy calorimeter is less than -20 dB, the range of the energy calorimeter is 10-600 J, the standard deviation of the five measurements is less than 5%. It can meet the requirements of HPM source’s within the transmission line or space radiation energy measurements.
参考文献

[1] 刘敏, 刘小龙, 晏峰, 等. 小型L波段高功率微波辐射场测量系统接收天线[J].强激光与粒子束, 2015, 27: 043002. (Liu Min, Liu Xiao-long, Yan Feng, et al. Miniaturized high power microwave radiation-field measuring antenna at L-band. High Power Laser and Particle Beams, 2015, 27: 043002)

[2] 孙钧, 胡咏梅, 张立刚,等. 圆波导定向耦合器在高功率微波测量中的应用[J].强激光与粒子束,2014, 26: 063040. (Sun Jun, Hu Yongmei, Zhang Ligang, et al. Application of circular waveguide couplers in high power microwave measurement. High Power Laser and Particle Beams, 2014, 26: 063040)

[3] 闫军凯,刘小龙,叶虎,等.X波段高功率微波馈源辐射总功率阵列法测量技术[J].强激光与粒子束,2011,23(11): 3149-3153.(Yan Junkai, Liu Xiaolong, Ye Hu, et al. X-band HPM feed total radiation power measurement using array method. High Power Laser and Particle Beams, 2011, 23(11): 3149-3153)

[4] Ives L R, Mizuhara Y M, Schumacher R V, et al. High power water load for microwave and millimeter-wave radio frequency sources: US, US 5949298 A[P]. 1999.

[5] Kiselev V A, Linnik A F, Onishchenko I N, et al. A calorimeter with a capacitive probe for measuring microwave energy[J]. Instruments and Experimental Techniques, 2005, 48(2): 230-233.

[6] 刘亮, 单家方, 刘甫坤,等. 新型大功率水负载的微波和流体设计[J]. 微波学报, 2008, 24(6): 32-35.(Liu Liang, Shan Jiafang, Liu Fukun, et al. Microwave and hydrokinetics design of a new kind high power water load. Journal of microwaves, 2008, 24(6): 32-35)

[7] Vykhodtsev P V, Elchaninov A A, Klimov A I, et al. Liquid calorimeters for measuring the energy of high-power microwave pulses[J].Instruments & Experimental Techniques, 2015, 58(4): 510-514.

[8] Tot’meninov E M, Vykhodtsev P V, Gunin A V, et al. Increase in the energy efficiency of a pulsed-periodic relativistic backward wave oscillator with a modulating resonant reflector[J]. Technical Physics, 2014, 59(3): 428-433.

[9] Chen Xupeng, Mankowski J, Hatfield L L, et al. The design of a broad band microwave pulse calorimeter[C]//Proceedings of 2005 IEEE Pulsed Power Conference. 2005: 194-197.

[10] Shkvarunets A, Kobayashi S,Carmel Y, et al. A broad band (4-25 GHz) calorimeter for diagnosing high power microwave sources[C]//IEEE Conference Record-abstracts IEEE International Conference on Plasma Science. 1999.

[11] Lisichkin A L, Nesterov E V, Petrov V Y, et al. A liquid pulsed microwave radiation calorimeter[J].Instruments and Experimental Techniques, 2007, 50(1): 82-85,57.

[12] Ye Hu, Ning Hui, Yang Wensen, et al. Research on calorimeter for high-power microwave measurements[J]. Review of Scientific Instruments, 2015, 86: 124706.

[13] 田彦民,宁辉,熊正锋,等. 绝热型微波脉冲能量计研究[J].试验工程,2008, 16(3): 1-4.(Tian Yanming, Ning Hui, Xiong Zhengfeng,et al. Study on adiabatic microwave pulse energy meter. Testing and Engineering, 2008, 16(3): 1-4)

[14] 郭焱华, 胡林林, 陈洪斌, 等. 3mm回旋管能量计的设计与实验[C]//全国微波毫米波会议. 2011: 1372-1375.(Guo Yanhua, Hu Linlin, Chen Hongbin, et al. Design and experimental investigation of the calorimeter for measure the energy of 3mm gyrotron//National Conference on Microwave and Millimeter Wave in China. 2011: 1372-1375)

[15] Chang Chao, Liu Guozhi, Tang Chuanxiang, et al. Review of recent theories and experiments for improving high-power microwave window breakdown thresholds[J]. Physics of Plasmas, 2011, 18(5): 339-348.

张翠翠, 王益, 王建忠. 新型全吸收式高功率微波能量计[J]. 强激光与粒子束, 2016, 28(11): 113001. Zhang Cuicui, Wang Yi, Wang Jianzhong. New type of high power energy calorimeter with full absorption[J]. High Power Laser and Particle Beams, 2016, 28(11): 113001.