激光与光电子学进展, 2004, 41 (2): 10, 网络出版: 2006-06-12
变折射率光纤折射率测量的误差分析
Error Analysis of Nonlinear Refractive-Index Profile Measurement of Fibers
摘要
介绍了使用双光束干涉法测量变折射率光纤设备的原理及实验结果。并对此方法进行了误差分析,对实际的设备制造提出了精度要求。
Abstract
The theory of nonlinear refractive-index profile measurement of fibers using two-beam interferometric method is introduced, and the result of this experiment is given. According to the theory and the method, the error analysis of the experiment and device is given. Due to the analysis, the precision of the components of the device is proposed.
参考文献
[1] 张煦. 新千年通信趋势. 电信建设, 2001,(3):2~8
[2] 谢克诚,刘光耀,罗康俊. 晶体折射率测试方法. 压电与声光, 1996, 18(1):62~66
[3] 殷宗敏. 光纤导论―――理论和元件. 上海: 上海交通大学出版社, 1995. 58~63
葛捷, 殷宗敏. 变折射率光纤折射率测量的误差分析[J]. 激光与光电子学进展, 2004, 41(2): 10. 葛捷, 殷宗敏. Error Analysis of Nonlinear Refractive-Index Profile Measurement of Fibers[J]. Laser & Optoelectronics Progress, 2004, 41(2): 10.