强激光与粒子束, 2013, 25 (11): 3021, 网络出版: 2013-11-14  

中子粉末衍射谱仪束流的椭圆聚焦镜设计

Design of ellipse focusing mirror for neutron powder diffraction complex
作者单位
1 中国工程物理研究院 核物理与化学研究所, 四川 绵阳 621900
2 中国科学技术大学 核科学技术学院, 合肥 230026
摘要
为使中子粉末衍射谱仪满足小样品研究需要,设计了一维椭圆聚焦镜系统并对参数进行了优化,同时对椭圆聚焦镜的相关参数做了较为详细讨论。采用椭圆解析计算和中子追迹程序McStas模拟两种方法,计算了椭圆聚焦镜参数对样品处中子注量率的影响,并以样品处中子注量率最大化为目标给出了优化参数,结果表明,在单色器(椭圆左焦点)到样品(椭圆右焦点)距离为2.7 m情况下,采用超镜因子为3、长度为25 cm的椭圆聚焦镜,其最佳位置为距离样品560 mm处、椭圆长半轴为1 350.016 mm,从而可以提高样品处注量率7倍。
Abstract
To meet the requirement of small sample studies on the neutron diffraction complex, a one-dimensional ellipse focusing mirror system was designed and its parameters were optimized. The effects of elliptical focusing mirror parameters on the neutron flux at sample were evaluated by both employing elliptical analytical calculation and neutron tracing simulation package McStas. And the optimal parameters of the mirror for the maximum neutron flux were investigated and obtained. The results show that in the case of the source (left ellipse focus) to the sample (right ellipse focus) distance of 2.7 m, the super mirror factor of 3 and the mirror length of 25 cm, the optimum right-position of the ellipse mirror is at distance 560 mm from sample and the half long axis is 1 350.016 mm. In optimized condition, the neutron flux at the sample can be improved 7 times.
参考文献

[1] Saerbeck T, Klose F. Neutron scattering and its application to investigate magnetic thin film structures[J]. Procedia Engineering, 2012, 36: 488-495.

[2] Feigin L A, Svergun D I. Structure analysis by small angle X-ray and neutron scattering[M]. New York: Plenum press, 1987.

[3] 陈华,黄朝强,孙光爱,等.中子应力谱仪常用聚焦单色器的模拟与比较[J].核电子学与探测技术, 2010, 30(3): 374-379.(Chen Hua, Huang Chaoqiang, Sun Guang’ai, et al. Simulation and comparison of general focusing monochromators for neutron diffractometer for stress measurement. Nuclear Electronics and Detection Technology, 2010, 30(3): 374-379)

[4] 黄朝强,李新喜,宋建明,等.中子反射谱仪前端导管优化[J].核技术, 2009, 32(6): 453-458.(Huang Chaoqiang, Li Xinxi, Song Jianming, et al. Optimization of pre-guide of neutron reflectometer. Nuclear Techniques, 2009, 32(6): 453-458)

[5] Suzuki J, Oku T, Adachi T, et al. Magnetic focusing devices for pulsed neutrons[C]//ICANS-XVI 16th Meeting of the International Collaboration on Advanced Neutron Sources. 2003.

[6] Mildner D F R, Chen-Mayer H H, Gibson W M. Focusing neutrons with tapered capillary optics[J]. Journal of Applied Physics, 2002, 92(11): 6911-6917.

[7] 中物院核物理与化学研究所. 中子粉末衍射谱仪[E/OL] (2011). http://www.caep.ac.cn/kxyj/hxyclxk/kxzz/10351.shtml (Institute of Nuclear Physics and Chemsitry, CAEP. Neutron powder diffraction complex (2011). http://www.caep.ac.cn/kxyj/hxyclxk/kxzz/10351.shtml)

[8] Rehm C, Agamalian M. Flux gain for a next-generation neutron reflectometer resulting from improved supermirror performance[J]. Applied Physics A, 2002, 74(1): s1483-s1485.

[9] Clausen K N, McMorrow D F, Lefmann K, et al. The RITA spectrometer at Ris-design considerations and recent results[J]. Physica B: Condensed Matter, 1997, 241/243: 50-55.

[10] Lefmann K, Nielsen K. MCSTAS, a general software package for neutron ray-tracing simulations[J]. Neutron News, 1999, 10(3): 20-23.

黄朝强, 王燕, 孙光爱, 李新喜, 陈波. 中子粉末衍射谱仪束流的椭圆聚焦镜设计[J]. 强激光与粒子束, 2013, 25(11): 3021. Huang Chaoqiang, Wang Yan, Sun Guang’ai, Li Xinxi, Chen Bo. Design of ellipse focusing mirror for neutron powder diffraction complex[J]. High Power Laser and Particle Beams, 2013, 25(11): 3021.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!