光学学报, 2017, 37 (4): 0434001, 网络出版: 2017-04-10   

铋光栅X射线相衬成像条纹对比度的定量计算 下载: 514次

Quantitative Calculation of Fringe Visibility in Bismuth Grating-Based X-Ray Phase-Contrast Imaging
作者单位
1 深圳大学光电工程学院广东省/教育部光电子器件与系统重点实验室, 广东 深圳 518060
2 深圳大学信息工程学院, 广东 深圳 518060
引用该论文

黄建衡, 雷耀虎, 杜杨, 刘鑫, 郭金川, 李冀, 郭宝平. 铋光栅X射线相衬成像条纹对比度的定量计算[J]. 光学学报, 2017, 37(4): 0434001.

Huang Jianheng, Lei Yaohu, Du Yang, Liu Xin, Guo Jinchuan, Li Ji, Guo Baoping. Quantitative Calculation of Fringe Visibility in Bismuth Grating-Based X-Ray Phase-Contrast Imaging[J]. Acta Optica Sinica, 2017, 37(4): 0434001.

参考文献

[1] Henke B L, Gullikson E M, Davis J C, et al. X-ray interactions: photoabsorption, scattering, transmission, and reflection at E=50-30,000 eV, Z=1-92[J]. Atomic Data and Nuclear Data Tables, 1993, 54(2): 181-342.

[2] Momose A. Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer[J]. Nuclear Instruments and Methods in Physics Research A, 1995, 352(3): 622-628.

[3] Bonse U, Hart M. An X-ray interferometer[J]. Applied Physics Letters, 1965, 6(8): 155-156.

[4] Davis T J, Gao D, Gureyev T E, et al. Phase-contrast imaging of weakly absorbing materials using hard X-rays[J]. Nature, 1995, 373(6515): 595-598.

[5] Wilkins S W, Gureyev T E, Gao D, et al. Phase-contrast imaging using polychromatic hard X-rays[J]. Nature, 1996, 384(6607): 335-338.

[6] David C, Nhammer B, Solak H H, et al. Differential X-ray phase contrast imaging using a shearing interferometer[J]. Applied Physics Letters, 2002, 81(17): 3287-3289.

[7] Pfeiffer F, Weitkamp T, Bunk O, et al. Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources[J]. Nature Physics, 2006, 2(4): 258-261.

[8] Pfeiffer F, Bech M, Bunk O, et al. Hard X-ray dark-field imaging using a grating interferometer[J]. Nature Materials, 2008, 7(2): 134-137.

[9] Stampanoni M, Wang Z, Thüring T, et al. The first analysis and clinical evaluation of native breast tissue using differential phase-contrast mammography[J]. Investigative Radiology, 2011, 46(12): 801-806.

[10] Momose A, Yashiro W, Kido K, et al. X-ray phase imaging: from synchrotron to hospital[J]. Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences, 2014, 372(2010): 20130023.

[11] Du Y, Liu X, Lei Y, et al. Non-absorption grating approach for X-ray phase contrast imaging[J]. Optics Express, 2011, 19(23): 22669-22674.

[12] 戚俊成, 任玉琦, 杜国浩, 等. 基于X射线光栅成像的多衬度显微计算层析系统[J]. 光学学报, 2013, 33(10): 1034001.

    Qi Jun cheng, Ren Yuqi, Du Guohao, et al. Multiple contrast micro-computed tomography system based on X-ray grating imaging[J]. Acta Optica Sinica, 2013, 33(10): 1034001.

[13] 李新斌, 陈志强, 张 丽, 等. 基于X射线光栅相衬成像的乳腺癌诊断技术的现状和发展前景[J]. 中国体视学与图像分析, 2015, 20(4): 305-318.

    Li Xinbin, Chen Zhiqiang, Zhang Li, et al. The status and development prospect of the diagnosis of breast cancer based on grating-based X-ray phase-contrast imaging[J]. Chinese Journal of Stereology and Image Analysis, 2015, 20(4): 305-318.

[14] 杜 杨, 刘 鑫, 雷耀虎, 等. 低成本高效率X射线相衬成像技术研究[J]. 光学学报, 2016, 36(3): 0334001.

    Du Yang, Liu Xin, Lei Yaohu, et al. Low cost and high efficiency method for X-ray phase contrast imaging[J]. Acta Optica Sinica, 2016, 36(3): 0334001.

[15] Wang S, Margie P O, Atsushi M, et al. Experimental research on the feature of an X-ray Talbot-Lau interferometer vs. tube accelerating voltage[J]. Chinese Physics B, 2015, 24(6): 068703.

[16] Donath T, Pfeiffer F, Bunk O, et al. Phase-contrast imaging and tomography at 60 keV using a conventional X-ray tube source[J]. Review of Scientific Instruments, 2009, 80(5): 053701.

[17] David C, Bruder J, Rohbeck T, et al. Fabrication of diffraction gratings for hard X-ray phase contrast imaging[J]. Microelectronic Engineering, 2007, 84(5-8): 1172-1177.

[18] Matsumoto M, Takiguchi K, Tanaka M, et al. Fabrication of diffraction grating for X-ray Talbot interferometer[J]. Microsystem Technologies, 2007, 13(5): 543-546.

[19] Rutishauser S, Bednarzik M, Zanette I, et al. Fabrication of two dimensional hard X-ray diffraction gratings[J]. Microelectronic Engineering, 2013, 101: 12-16.

[20] Lei Y, Du Y, Li J, et al. Application of Bi absorption gratings in grating-based X-ray phase contrast imaging[J]. Applied Physics Express, 2013, 6(11): 117301.

[21] Lei Y, Du Y, Li J, et al. Fabrication of X-ray absorption gratings via micro-casting for grating-based phase contrast imaging[J]. Journal of Micromechanics and Microengineering, 2014, 24(1): 015007.

[22] Revol V, Kottler C, Kaufmann R, et al. Noise analysis of grating-based X-ray differential phase contrast imaging[J]. Review of Scientific Instruments, 2010, 81(7): 073709.

[23] Modregger P, Pinzer B R, Thüring T , et al. Sensitivity of X-ray grating interferometry[J]. Optics Express, 2011, 19(19): 18324-18338.

[24] 黄建衡, 杜 杨, 雷耀虎, 等. 硬X射线微分相衬成像的噪声特性分析[J]. 物理学报, 2014, 63(16): 168702.

    Huang Jianheng, Du Yang, Lei Yaohu, et al. Noise analysis of hard X-ray differential phase contrast imaging[J]. Acta Physica Sinica, 2014, 63(16): 168702.

[25] Boone J M, Seibert J A. An accurate method for computer-generating tungsten anode X-ray spectra from 30 to 140 kV[J]. Medical Physics, 1997, 24(11): 1661-1670.

黄建衡, 雷耀虎, 杜杨, 刘鑫, 郭金川, 李冀, 郭宝平. 铋光栅X射线相衬成像条纹对比度的定量计算[J]. 光学学报, 2017, 37(4): 0434001. Huang Jianheng, Lei Yaohu, Du Yang, Liu Xin, Guo Jinchuan, Li Ji, Guo Baoping. Quantitative Calculation of Fringe Visibility in Bismuth Grating-Based X-Ray Phase-Contrast Imaging[J]. Acta Optica Sinica, 2017, 37(4): 0434001.

本文已被 3 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!