摘要
采用二元光学透镜作为分光元件的多光谱成像光谱仪,由于焦距随波长的变化改变了系统的F数,因此改变了系统的放大率,从而引起光谱图像的像元配准误差.为改进基于二元光学透镜的多光谱成像光谱仪的性能,首次提出将离轴三反射镜系统与具有二元光学透镜的变焦距系统相结合的新技术方案.设计了由三片二次非球面生成的无中心遮拦的前置望远镜,该望远镜不仅有利于提高多光谱成像光谱仪的集光能力,且有利于系统的小型轻量化.同时设计了含二元光学透镜的三片型变焦距组件,用来消除多光谱成像光谱仪的像元配准误差.整个多光谱成像光谱仪系统仅有6个单片,非常简单.另外,该系统在空间频率为20 c/mm时MTF超过0.3,充分满足红外焦平面探测器对多光谱成像系统分辨率的要求,像面尺寸为7.2 mm.适用于探测单元尺寸为25 μm、规格为128×128元的红外焦平面探测器.
Abstract
The magnification changing with the incident wavelength, which would bring the different spectral image matching error, is inevitable in the multispectral infrared imaging spectrometer using binary optical element (BOE) as spectro"element because its focal length changes with incident wavelength. To improve the optical performance of the multispectral infrared imaging spectrometer, the hybrid refraction/ diffraction zoom optical system combining the off"axial three"mirror system is firstly put forward. The front element of multispectral infrared imaging spectrometer is an unobscured and afocal three "mirror telescope,which not only makes for enlarging the clear aperture of multispectral infrared imaging spectrome" ter,but also reduces the size and weight.The rear elements of multispectral infrared imaging spectrometeris a hybrid refractive/diffractive three#elements zoom optical system, which eliminates the different spec-tral image matching error in the multispectral infrared imaging spectrometer using BOE aThe magnification changing with the incident wavelength, which would bring the different spectral image matching error, is inevitable in the multispectral infrared imaging spectrometer using binary optical element (BOE) as spectro"element because its focal length changes with incident wavelength. To improve the optical performance of the multispectral infrared imaging spectrometer, the hybrid refraction/ diffraction zoom optical system combining the off"axial three"mirror system is firstly put forward. The front element of multispectral infrared imaging spectrometer is an unobscured and afocal three "mirror telescope,which not only makes for enlarging the clear aperture of multispectral infrared imaging spectrome" ter,but also reduces the size and weight.The rear elements of multispectral infrared imaging spectrometeris a hybrid refractive/diffractive three#elements zoom optical system, which eliminates the different spec-tral image matching error in the multispectral infrared imaging spectrometer using BOE as spectro element The designed system is very simple in structure. Moreover, the modulation transfer function (MTF) of the designed system is greater than 0.3 for 20 c/mm spatial frequency, which meets the resolution requirement of the stare array detector of the multispectral infrared imaging spectrometer. In addition, the image size of the designed system is 7.2 mm, which meets 25 μm detector cell and 128 ×128 infrared detector arrays.
参考文献

[1] WANG Huai-yi,GAO Jun. Analysis and development on aerospace infrared optical remote sensor[J].Infrared and Laser Engineering (王怀义,高军.空间红外光学遥感器发展现状及前景分析.红外与激光工程),1999,28(2):1-6.

[2] . Development and application of multi-spetral imaging technology for satellite[J]. Space International(王臻.卫星多光谱成像技术的发展与应用.国际太空), 2000, 2: 26-27.

[3] Wallance M P,Enmark H T.A system overview of the airborne visible/infrared imaging pectrometer(AVIRIS)[A].SPIE[C].1987,834.166-174.

[4] Rockey D E.High resolution imaging spectrometer (HIRIS)a major advance in imaging spectrometry[A].SPIE[C].1990,1298.93-104.

[5] Lyons D.Image spectrometry with a diffractive[A].SPIE[C].1995,2480.123-131.

[6] JIN Guo-fan,YAN Ying-bai,WU Min-xian ,et al. Binary Optics[M].Beijing:National Defence Industry Press(金国藩,严瑛白,吴敏贤,等.二元光学.北京:国防工业出版社),1998,181-210.

[7] Hinnrichs M,Massie M.New approach to imaging spectroscopy using diffractive optics [A]. SPIE [C]. 1997,3118.194-205.

[8] SUN Qiang,Wang Zhao-qi,Liu Hong-bo,et al. Optical system of harmonic diffractive/refractive for infrared dual-color detector[J].Infrared and Laser Engineering(孙强,王肇圻,刘宏波,等,应用于双色探测器的谐衍射/折射光学系统.红外与激光工程),2003,32(3):317-321.

[9] TAO Chun-kan. Zoom System Design[M].Beijing:National Defence Industry Press(陶纯堪.变焦距光学系统设计.北京:国防工业出版社),1988.

[10] WU Xiao-jing,SUN Chi-quan,MENG Jun-he. Relationship between athermalizing infrared optical system and zoom lens [J].Infrared and LaserEngineering(吴晓靖,孙赤全,孟军和,等,红外光学系统无热差设计与变焦距镜头的关系.红外与激光工程),2002,31(3):249-252.

[11] CHANG Jun, WENG Zhi-cheng,JIANG Hui-lin,et al. Design of long focal length space optical system with three reflective mirrors[J].Optics and Precision Engineering(常军,翁志成,姜会林,等.长焦距空间三反光学系统的设计.光学精密工程),2001,9(4):315-318.

杨新军, 王肇圻, 母国光. 折/衍混合多光谱红外成像光谱仪离轴系统设计[J]. 红外与激光工程, 2005, 34(4): 379. 杨新军, 王肇圻, 母国光. Design of hybrid refractive/diffractive off-axial optical system for multispectral infrared imaging spectrometer[J]. Infrared and Laser Engineering, 2005, 34(4): 379.

本文已被 7 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!