光子学报, 2005, 34 (7): 1036, 网络出版: 2006-06-12   

侧面研磨光纤Bragg光栅的外部折射率敏感特性研究

The response of side-polished FBG to external refractive index
作者单位
浙江大学信息与电子工程学系,杭州,310027
摘要
光纤Bragg光栅对外界折射率的变化不灵敏,无法直接作为气体、液体等的敏感元件.侧面研磨的光纤Bragg光栅,一侧包层减小至几微米,其辐射场可通过包层透射到被传感物质,因而被传感物质的折射率的变化可以改变光纤的有效折射率,从而使光栅的Bragg波长产生位移.实验中利用不同浓度的NaCl溶液来改变光纤光栅的外部折射率,Bragg中心波长的偏移量和浓度近似为线性关系.同时,透射功率的变化量和浓度也近似为线性关系.
Abstract
Fiber Bragg grating (FBG) cannot be directly used as gas or liquids sensors, because it is not sensitive to external refractive index.By side-polished,the cladding layer of one side of FBG can be reduced to several micrometers.The radiation field can reach the external medium.When the external refractive index changes, the effective refractive index of fiber changes and the center wavelength of D-shaped FBG shifts accordingly.In the experiment,the NaCl solution with different concentration is used to change the external refractive index of FBG.The center wavelength of D-shaped FBG shifts when the concentration of NaCl solution changes.The relationship between the offset of wavelength and the concentration of NaCl solution is approximately linear.In addition,the relationship between the transmitting power and the concentration of NaCl solution is also approximately linear.
参考文献

[1] 从军,陈旭明,章献民.啁啾双光栅群时延特性.光子学报,2004,33(3):299~302 Cong J, Chen X M, Zhang X M. Acta Photonica Sinica,2004,33(3) :299~302

[2] Zhang Weigang, Dong Xiaoyi, Zhao Qida, et al. FBG-type sensor for simultaneous of force and temperature based on bilateral cantilever beam. IEEE Photon Technol Lett ,2001,13(4): 1340~1342

[3] Jung Jaehoon, Nam Hui, Lee Byoungho, et al. Fiber Bragg grating temperature sensor with controllable sensitivity. Applied Optics, 1999,38(13) :2752~2754

[4] 郭团,乔学光,贾振安,等.基于光纤Bragg光栅反射波带宽展宽的压力传感研究.光子学报,2004,33(3).288~290 Guo T,Qiao X G,Jia Z A,et al. Acta Photonica Sinica,2004,33(3) :288~290

[5] Cong Jun,Zhang Xianmin,Chen Kangsheng, et al. Fiber optic Bragg grating sensor based on hydrogels for measuring salinity. Sensors and Actuators B : Chemical,2002,87(3) :487~490

[6] Patrick J H, Kersey A D, Bucholtz F. Analysis of the response of long period fiber gratings to external index of refraction. J Lightwave Technol, 1998, 16 (9): 1606 ~1612

[7] Muhammad F A,Stewart G. D-shaped optical fiber design for methane gas sensing. Electro Lett, 1992,28(13): 1205~1206

[8] 张霞,夏月辉,黄永清,等.有限包层半径光纤Bragg光栅的理论研究.光子学报,2003,32(2):222~224 Zhang X, Xia Y H, Huang Y Q, et al. Acta Photonica Sinica, 2003,32 (2): 222~224

[9] Cordaro M H, Rode D L, Barry T S, et al. Precision fabrication of D-shaped single-mode optical fibers by In Situ Monitoring. J Llightwave Technol, 1994,12 (9):1524~1531

沈乐, 郑史烈, 章献民. 侧面研磨光纤Bragg光栅的外部折射率敏感特性研究[J]. 光子学报, 2005, 34(7): 1036. 沈乐, 郑史烈, 章献民. The response of side-polished FBG to external refractive index[J]. ACTA PHOTONICA SINICA, 2005, 34(7): 1036.

本文已被 12 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!