强激光与粒子束, 2014, 26 (4): 043201, 网络出版: 2014-04-24   

电磁干扰下时间分辨测量系统信号外触发技术

External trigger technique of high speed signal of beam parameters measurement system under strong electromagnetic interruption
作者单位
中国工程物理研究院 流体物理研究所, 四川 绵阳 621900
摘要
在实验的基础上给出了束参数时间分辨测量系统的实验布局和特点,分析高压电磁干扰对直线感应加速器中时间分辨测量系统外触发性能的影响和变化规律; 进一步探讨系统高压电磁干扰后的抑制措施。针对电磁空间干扰情况,主要通过采用光纤传输控制信号的措施,能很好地传输窄脉冲,信号延时抖动小于2 ns,达到了高速信号的可靠传输要求,采用嵌入式控制器既解决了抗电磁干扰的要求,也满足了束参数时间分辨测量系统的使用要求。
Abstract
Strong electromagnetic interference in the high power linear induction accelerator (LIA) is disadvantageous to electron-beam-parameters measurement and diagnosis system. In this paper, electromagnetic interference effect on time-resolved electron-beam-parameter measurement system is analyzed, and the method for controlling the electromagnetic interference is discussed. With fiber embedded technology, narrow impulse signals are dependably transmitted, signal delay jitter is less than 2 ns. The experiment showed that the measuring system is characterized with the features of high reliability and achieves the application requirements.
参考文献

[1] 刘锡三.高功率脉冲技术[M].北京: 国防工业出版社, 2005.(Liu Xisan. High pulsed power technology. Beijing: National Defense Industry Press, 2005)

[2] 白同云,吕晓德.电磁兼容设计[M].北京: 北京邮电大学出版社, 2001.(Bai Tongyun, Lü Xiaode. Electromagntic compatibility design. Beijing: Beijing University of Posts and Telecommunications Press, 2001)

[3] Benford J, Swehle J. High power microwaves[M]. Norwood: Artech House, 1992.

[4] 江孝国,李成刚,王远,等.神龙一号电子束束参数测量系统猝发式的精确触发方式研究[J].高能物理与核物理, 2006, 30(8): 784-787.(Jiang Xiaoguo, Li Chenggang, Wang Yuan, et al. Accurate burst trigger mode for dragon-1 electron beam measurement system. High Energy Physics and Nuclear Physics, 2006, 30(8): 784-787)

[5] 王远,江孝国,杨国君,等.OTR时间分辩测量系统的嵌入式远程控制方法[J].强激光与粒子束, 2006, 15(1): 101-104.(Wang Yuan, Jiang Xiaoguo, Yang Guojun, et al. Methods of embedded computing remote control by time-resolved OTR measure system. High Power Laser and Particle Beams, 2006, 15(1): 101-104)

[6] 邱孟通,吕敏,王奎禄,等.Z-pinch X射线时间分辨多幅图像诊断系统[J].强激光与粒子束, 2003, 15(1): 101-104.(Qiu Mengtong, Lü Min, Wang Kuilu, et al. Time resolved X-ray image diagnostics system for Z pinch. High Power Laser and Particle Beams, 2003, 15(1): 101-104)

[7] 薛飞彪,杨建伦,李正宏.紫外探针光信号与加速器负载电流脉冲的精密同步技术[J].强激光与粒子束, 2005, 17(1): 149-152.(Xue Feibiao, Yang Jianlun, Li Zhenghong. Precise synchronization of UV laser probe system with the load current of accelerator. High Power Laser and Particle Beams, 2005, 17(1): 149-152)

[8] 江孝国,王远,杨国君,等.时间分辨的强流脉冲电子束参数的光学测量诊断系统研制[J].强激光与粒子束, 2013, 25(11): 2780-2784.(Jiang Xiaoguo, Wang Yuan, Yang Guojun, et al. Development of time-resolved optical measurement and diagnostic system for parameters and pulsed electronbeam. High Power Laser and Particle Beams, 2013, 25(11): 2780-2784)

[9] 王远,谢宇彤,陈思富,等.高能电子辐照对束测量系统的影响[J].强激光与粒子束, 2012, 24(4): 949-952.(Wang Yuan, Xie Yutong, Chen Sifu, et al. Influence of high energy electron irradiation on beam parameters measurement system. High Power Laser and Particle Beams, 2012, 24(4): 949-952)

[10] 靳振兴,张军,雷应,等.石墨阴极用于重频长脉冲高功率微波产生的初步实验[J].强激光与粒子束, 2011, 23(5): 1307-1311.(Jin Zhenxing, Zhang Jun, Lei Ying, et al. Preliminary experimental investigation on repetitively long-pulse HPM generation using graphit cathode cathode. High Power Laser and Particle Beams, 2011, 23(5): 1307-1311)

王远, 江孝国, 陈思富, 李杰, 谢宇彤, 禹海军, 李劲. 电磁干扰下时间分辨测量系统信号外触发技术[J]. 强激光与粒子束, 2014, 26(4): 043201. Wang Yuan, Jiang Xiaoguo, Chen Sifu, Li Jie, Xie Yutong, Yu Haijun, Li Jin. External trigger technique of high speed signal of beam parameters measurement system under strong electromagnetic interruption[J]. High Power Laser and Particle Beams, 2014, 26(4): 043201.