摘要
结合太赫兹辐射源及焦平面探测器特性, 同时考虑目标-背景特性、大气衰减及器件衰减等影响, 研究建立了太赫兹主动成像系统的最小可分辨对比度匹配滤波器模型.并结合文献示例以及实际太赫兹焦平面主动成像系统的测试结果, 验证了最小可分辨对比度模型.结果表明, 实验测量值和计算值基本一致, 误差在合理范围之内, 从而表明了本文模型的有效性.
Abstract
Based on the characteristics of terahertz source and focal plane detector, the minimum resolvable contrast(MRC) matched filter model of terahertz active imaging system is established by considering the influence of target-background characteristic, atmospheric attenuation and device attenuation. The MRC model is validated by combining the literature examples and the experimental results of the actual terahertz focal plane active imaging system. The results show that the measured value and the calculated value are basically the same, with the error in the reasonable range, which shows the validity of the model.
参考文献

[1] Lee A W, Hu Q. Real-time, continuous-wave terahertz imaging by use of a microbolometer focal-plane array[J]. Optics letters, 2005, 30(19): 2563-2565.

[2] JIN Wei-qi, TIAN Li, WANG Hong-chen, et al. Review of THz Focal Plane Detector and the Development of Its Imaging Technology [J]. Infrared Technology, (金伟其,田莉,王宏臣, 等. THz 焦平面探测器及其成像技术发展综述. 红外技术)2013, 35(4): 187-194.

[3] INO. IRXCAM-THz-384[OL]. (2013) [2017.5.14].http://www.ino.ca/en/technologies/imaging%C2%A0systems/terahertz-camera-module/.

[4] TIAN Li, JIN Wei-qi, CAI Yi, et al. Imaging area and contrast of THz focal plane array CW transmission imaging system [J]. Optics and Precision Engineering, (田莉, 金伟其, 蔡毅, 等. THz焦平面连续波透射成像系统的成像面积及对比度. 光学 精密工程) 2015, 23(8): 2164-2170.

[5] Scott L B, D'Agostino J A. NVEOD FLIR92 thermal imaging systems performance model[C]. Aerospace Sensing, 1992: 194-203.

[6] Murrill S R, Jacobs E L, Moyer S K, et al. Terahertz imaging system performance model for concealed-weapon identification [J]. Applied Optics, 2008, 47(9):1286-1297.

[7] Bijl P. Bias-free procedure for the measurement of the minimum resolvable temperature difference and minimum resolvable contrast [J]. Optical Engineering, 1999, 38(10):1735-1742.

[8] Oda N, Hosako I, Ishi T, et al. The Need of Terahertz Cameras for Standardizing Sensitivity Measurements [J]. Journal of Infrared, Millimeter, and Terahertz Waves, 2014, 35(8): 671-685.

[9] Lloyd J M. Thermal imaging systems[M]: Springer Science & Business Media, 2013.

[10] Ratches J A, Lawson W R, Obert L P, et al. Night vision laboratory static performance model for thermal viewing systems[M]. In.:DTIC Document; 1975: 8-9.

[11] Driggers R G. Analysis and Evaluation of Sampled Imaging Systems[M], 2010: 31-59.

[12] KOU X M. Evaluation Method Research of Overall Performance for Infrared Imaging and Observation System [D].(寇小明. 红外成像观测系统性能评价方法研究. 西安电子科技大学) Xi'an: Xi'an University of Electronic Science and Technology.

[13] BAI T Z, JIN W Q. Principle and Technology of Photoelectric Imaging[M].Beijing: Beijing Institute of Technology Press, (白廷柱, 金伟其. 光电成像原理及技术. 北京理工大学出版社), 2006: 514.

[14] Dudzik M C, Accetta J, Shumaker D. The Infrared & Electro-Optical Systems Handbook, Vol. 4[J]. Electro-Optical Systems Design, Analysis, and Testing, 1993: 91-93.

[15] ZHOU Y, JIN Wei-qi. The transfer characteristic of human visual system and models[J]. Optical Technique, (周燕, 金伟其. 人眼视觉的传递特性及模型[J]. 光学技术) 2002, 28(1): 57-61.

[16] Espinola R L, Jacobs E L, Halford C E, et al. Modeling the target acquisition performance of active imaging systems [J]. Optics express, 2007, 15(7): 3816.

[17] SIFIR-50.[2017.5,14]. https://www.coherent.com/lasers/.

[18] Introduction of NEC THz Product: High Sensitivity Real-Time Uncooled THz Imager and Transmission THz Microscope [2017.5.14].http://www.nec.com/en/.

[19] Rosker M J, Wallace H B. Imaging Through the Atmosphere at Terahertz Frequencies[C]. Microwave Symposium, 2007. IEEE/MTT-S International, 2007: 773-776.

田莉, 金伟其, 蔡毅, 王霞. 太赫兹主动焦平面成像系统的MRC匹配滤波器模型[J]. 红外与毫米波学报, 2017, 36(6): 680. TIAN Li, JIN Wei-Qi, CAI Yi, WANG Xia. The MRC matched filter model of terahertz active focal plane imaging system[J]. Journal of Infrared and Millimeter Waves, 2017, 36(6): 680.