Chinese Optics Letters, 2017, 15 (2): 020603, Published Online: Jul. 26, 2018  

Temperature-insensitive refractive index sensor based on Mach–Zehnder interferometer with two microcavities Download: 1121次

Author Affiliations
1 Laser Micro/Nano Fabrication Laboratory, School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China
2 Vibration and Noise Control Laboratory, School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, China
3 School of Optoelectronics, Beijing Institute of Technology, Beijing 100081, China
Figures & Tables

Fig. 1. Schematic diagram of the microcavities-based MZI.

下载图片 查看原文

Fig. 2. Microscopic image of (a) the PCF cross-section, (b) microcavity 1 of sensor 2, (c) microcavity 1 of sensor 3, (d) microcavity 1 of sensor 4, and (e) microcavity and collapse area.

下载图片 查看原文

Fig. 3. Transmission spectra of the sensors 1, 2, 3, and 4.

下载图片 查看原文

Fig. 4. Wavelength shifts of interference spectrum of (a) sensor 1, (b) sensor 2, (c) sensor 3, and (d) sensor 4.

下载图片 查看原文

Fig. 5. Relations between wavelength shifts and the surrounding RI of different sensors.

下载图片 查看原文

Fig. 6. Spatial frequency spectra of sensors 1 and 4.

下载图片 查看原文

Fig. 7. Wavelength shifts with the increase of the temperatures for sensor 4.

下载图片 查看原文

Table1. Microcavity Sizes and Related Arc Powera

ParametersSensor 2Sensor 3Sensor 4
Arc power (%)70%60%50%
ED 1 (μm)33.138.344.6
PD 1 (μm)14.312.010.6
ED 2 (μm)30.936.642.9
PD 2 (μm)15.113.110.0