光学学报, 2008, 28 (3): 609, 网络出版: 2008-03-24   

同轴X射线相位衬度计算机X射线断层摄影术研究

In-Line X-Ray Phase-Contrast Computerized Tomography
作者单位
中国科学技术大学国家同步辐射实验室, 安徽 合肥 230029
摘要
基于北京同步辐射装置(BSRF)开展了同轴X射线相位衬度计算机X射线断层摄影术(CT)研究。利用北京同步辐射的14 keV单色X射线作为光源,以高分辨能力的X射线胶片作为探测器,分别开展吸收衬度和同轴相位衬度成像的比较研究以及相位衬度计算机X射线断层摄影术研究。相位衬度计算机X射线断层摄影术重建采用Bronnikov提出的算法。结果显示,与传统的吸收衬度图像相比,相位衬度图像具有更好的衬度和更高的空间分辨力;实验获得人工样品和蝗虫的相位衬度计算机X射线断层摄影术重建图像。重建图像中可见样品的一些结构细节。实验结果表明,相位衬度X射线成像更适合于研究弱吸收或吸收差异很小的材料;利用北京同步辐射开展同轴X射线相位衬度计算机X射线断层摄影术研究是可行的。
Abstract
To develop the in-line X-ray phase-contrast computerized tomography (CT) method based on synchrotron radiation in Beijing Synchrotron Radiation Facility (BSRF). The comparison studies of in-line phase-contrast imaging with absorption-contrast imaging as well as the technique of in-line phase-contrast computerized tomography were carried out using the 14 keV monochromatic X-ray from BSRF as the light source and the X-ray film with high-resolution power as the detector. The algorithm proposed by Bronnikov was employed for the phase-contrast CT reconstruction. Compared with conventional absorbing-contrast images, phase-contrast images have better contrast and higher spatial resolution. Phase-contrast CT reconstruction images of the experimental samples were acquired and some feature details of the objects could be seen in the reconstruction images. The above experimental results indicate that phase-contrast X-ray imaging method is more applicable to the studies of the materials with weakly absorbing and small absorption difference, and it is feasible to carry out in-line X-ray phase-contrast CT using X-ray source of BSRF.
参考文献

[1] . Momose. Demonstration of phase-contrast X-ray computed tomography using an X-ray interferometer[J]. Nucl. Instrum. Methods A, 1995, 352: 622-628.

[2] . N. Ingal, E. A. Beliaevskaya. X-ray plane wave topography observation of the phase contrast from a non crystalline object[J]. J. Phys. D, 1995, 28(11): 2314-2317.

[3] . Optimization of X-ray phase-contrast imaging based on in-line holography[J]. Nucl. Instr. And Meth. In Phys. Res. B, 2005, 234(3): 563-572.

[4] . Snigirev, I. Snigireva, V. Kohn et al.. On the possibilities of X-ray phase contrast microimaging by coherent high-energy synchrotron radiation[J]. Rev. Sci. Instrum., 1995, 66(12): 5486-5492.

[5] . E. Gureyev, C. Raven, A. Snigirev et al.. Hard X-ray quantitative non-interferometric phase-contrast microscopy[J]. J. Phys. D, 1999, 32(5): 563-567.

[6] . W. Wilkins, T. E. Gureyev, D. Gao et al.. Phase-contrast imaging using polychromatic hard X-rays[J]. Nature, 1996, 384(6607): 335-338.

[7] . Pogany, D. Gao, S. W. Wilkins. Contrast and resolution in imaging with a microfocus X-ray source[J]. Rev. Sci. Instrum., 1997, 68(7): 2774-2782.

[8] Yu Hong, Zhu Pinpin, Han Shensheng. A study of diffractive phase imaging and phase restoration with partially coherent X-ray[J]. Acta Optica Sinica, 2003, 23(4): 390~397
喻虹, 朱频频,韩申生. 部分相干X射线衍射相位成像与相位复原的模拟研究[J]. 光学学报, 2003, 23(4): 390~397

[9] Gao Hongyi, Chen Jianwen, Xie Honglan et al.. Experimental results of X-ray diffraction enhanced phase contrast imaging[J]. Acta Optica Sinica, 2004, 24(8): 1151~1152
高鸿奕,陈建文, 谢红兰 等. X射线衍射增强相衬成像的实验结果[J]. 光学学报, 2004, 24(8): 1151~1152

[10] . . On in line X-ray phase contrast imaging[J]. Acta Photonica Sinica, 2006, 35(6): 886-889.

[11] . . In vivo evaluation of early disease progression by X-ray phase contrast imaging in the adjuvant arthritis rat[J]. Chin. J. Rheumatology, 2004, 8(8): 471-475.

[12] Sun Yi, Zhu Peiping, Yu Jian et al.. Absorption, refraction and extinction contrast computerized tomography of X-ray diffraction enhanced imaging method[J]. Acta Optica Sinica, 2007, 27(4): 749~754
孙怡,朱佩平,于健 等. X射线衍射增强成像中吸收、折射以及散射衬度的计算层析[J]. 光学学报, 2007, 27(4): 749~754

[13] . . Phase-contrast imaging with microfocus X-ray source[J]. Acta Physica Sinica, 2004, 53(9): 2953-2957.

[14] . Raven, A. Snigirev, I. Snigireva et al.. Phase-contrast microtomography with coherent high-energy synchrotron X-rays[J]. Appl. Phys. Lett., 1996, 69(13): 1826-1828.

[15] . Pfeiffer, C. Kottler, O. Bunk et al.. Hard X-ray phase tomography with low-brilliance source[J]. Phys. Rev. Lett., 2007, 98(10): 108105-108108.

[16] . J. McMahon, A. G. Peele, D. Paterson et al.. X-ray tomographic imaging of the complex refractive index[J]. Appl. Phys. Lett., 2003, 83(7): 1480-1482.

[17] . E. Gureyev, K. A. Nugent. Phase retrieval with the transport-of-intensity equation. Ⅱ. Orthogonal series solution for nonuniform illumination[J]. J. Opt. Soc. Am. A, 1996, 13(8): 1670-1682.

[18] T. E. Gureyev, S. W. Wilkins. On X-ray phase retrieval from polychromatic images[J]. Opt. Commun., 1998, 147(4~6): 229~232

[19] Andrei V. Bronnikov. Reconstruction formulas in phase-contrast tomography[J]. Opt. Commun., 1999, 171(4~6): 239~244

[20] . Bronnikov. Theory of quantitative phase-contrast computed tomography[J]. J. Opt. Soc. A, 2002, 19(3): 472-480.

蒋诗平, 李妹芳, 陈阳, 陈亮. 同轴X射线相位衬度计算机X射线断层摄影术研究[J]. 光学学报, 2008, 28(3): 609. Jiang Shiping, Li Meifang, Chen Yang, Chen Liang. In-Line X-Ray Phase-Contrast Computerized Tomography[J]. Acta Optica Sinica, 2008, 28(3): 609.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!