激光与光电子学进展, 2013, 50 (11): 112301, 网络出版: 2013-10-20  

基于比色法的纯镁及镁合金燃点测试系统

Ignition Test System of Pure Magnesium and Magnesium Alloys Based on Colorimetric Method
作者单位
中北大学电子测试技术国家重点实验室, 山西 太原 030051
摘要
针对纯镁及镁合金的燃点难判定及热电偶测量破坏被测温度场分布、使用寿命短、难以小型化等问题,设计了一种新的比色测温装置。介绍了装置的基本结构及测温原理;提出了根据装置接收的两路光辐射变化的拐点来确定其起燃时间的方法,其对应温度即为燃点温度;利用光纤光谱仪测量纯镁燃烧前后的光谱作为系统波长和带宽选取的参考,计算发射率比值并将其用于温度修正;利用中温黑体炉对比色测温装置进行静态标定,获得静态灵敏度系数;最后以CO2激光器作为热源来点燃纯镁和镁合金AZ91D,同时用比色测温装置和红外测温仪进行燃点测试。实验结果表明,纯镁和镁合金AZ91D测量结果的相对误差分别为1.43%和1.08%。
Abstract
Due to the difficulties of judgments in magnesium and its alloys′ ignition points and problems of measured temperature field distribution influenced by thermocouples, short lifespan and inconvenient miniaturization, a new kind of colorimetric temperature test device is designed. The basic structure and test principle of this device are introduced. According to the inflection point of changes in two channels of received optical radiation, the burning time is confirmed and the corresponding temperature is just the ignition point. A fiber optic spectrometer is used to test the spectra before and after combustion, which provide a reference for choosing system′s wavelength and bandwidth, and temperature correction is performed with calculating the ratio of emissivity. A temperature of blackbody furnace is used to do static calibration for the colorimetric test device to decide the systematic wavelength and bandwidth. Finally, a CO2 laser is employed as the heat source to ignite pure magnesium and magnesium alloy AZ91D. The colorimetric temperature test device and infrared thermometer are used to do ignition test. The results test show that the relative error of pure magnesium and magnesium alloy AZ91D are 1.43% and 1.08%, respectively.
参考文献

[1] 全亚杰. 镁合金激光焊的研究现状及发展趋势[J]. 激光与光电子学进展, 2012, 49(5): 050001.

    Quan Yajie. Research status and development trends of laser welding of magnesium alloy[J]. Laser & Optoelectronics Progress, 2012, 49(5): 050001.

[2] 葛茂忠, 项建云, 张永康. 激光冲击处理对AZ31B镁合金焊接件抗应力腐蚀的影响[J]. 中国激光, 2012, 39(12): 1203007.

    Ge Maozhong, Xiang Jianyun, Zhang Yongkang. Effect of laser shock processing on resistance to stress corrosion cracking of tungsten inert-gas welded AZ31B magnesium alloy[J]. Chinese J Lasers, 2012, 39(12): 1203007.

[3] 赵鸿金, 张迎辉, 康永林. 稀土元素Ce对AZ91D镁合金燃点的影响[J]. 轻合金加工技术, 2008, 36(2): 42-57.

    Zhao Hongjin, Zhang Yinghui, Kang Yonglin. Effect of cerium on the ignition point of AZ91D magnesium alloy[J]. Light Alloy Fabrication Technology, 2008, 36(2): 42-57.

[4] 赵标, 佘俊. 热电偶测温及冷端补偿研究与实现[J]. 上海船舶运输科学院技术学报, 2013, 36(1): 50-53.

    Zhao Biao, She Jun. Research and design of cold junction compensation in thermocouple temperature measurement[J]. J Shanghai Ship and Shipping Research Institute, 2013, 36(1): 50-53.

[5] 徐德辉, 熊斌, 王跃林. CMOS兼容自对准微机械热电堆红外探测器[J]. 光学学报, 2010, 30(10): 2817-2820.

    Xu Dehui, Xiong Bin, Wang Yuelin. CMOS compatible self-aligned micromachined thermopile IR detector[J]. Acta Optica Sinica, 2010, 30(10): 2817-2820.

[6] 王大振. 多通道热电偶和双色红外测温系统的研制及应用研究[D]. 济南: 山东大学, 2012.

    Wang Dazhen. Development and Application Study of Two-Color Infrared Thermometer and Multichannel Thermocouple Acquisition System[D]. Ji′nan: Shandong University, 2012.

[7] 陈萍, 张茂勋. 镁及镁合金燃点的测试[J]. 特种铸造及有色合金, 2002, (s1): 323-326.

    Chen Ping, Zhang Maoxun. Measurement for theflammability point of Mg and Mg alloy[J]. Special Casting & Nonferrous alloys, 2002, (s1): 323-326.

[8] 温鹏, 荻崎贤二, 山本元道. 基于在线观察的激光焊接凝固热裂纹敏感性研究[J]. 中国激光, 2011, 38(6): 0603005.

    Wen Peng, Shinozaki Kenji, Yamamoto Motomichi. Evaluation of solidification cracking susceptibility during laser welding by in-situ observation method[J]. Chinese J Lasers, 2011, 38(6): 0603005.

[9] B L Bobryshev. Ignition of magnesium and its alloys[J]. Metal Science and Heat Treatment, 1988, 30(3): 219-222.

[10] 王海福, 郑珊, 马顺山, 等. 粉尘云最小点火温度测试实验系统设计[J]. 中国安全科学学报, 2001, 11(6): 52-54.

    Wang Haifu, Zheng Shan, Ma Shunshan, et al.. Design of the experiment system for the determination of the minimum ignition temperature of dust clouds[J]. China Safety Science Journal, 2001, 11(6): 52-54.

[11] 朱剑华, 郝晓剑, 周汉昌. 基于比色测温的瞬态高温测试方法及系统实现[J]. 自动化与仪表, 2010, (9): 5-8.

    Zhu Jianhua, Hao Xiaojian, Zhou Hanchang. Implementation of the measurement method and system for transient high-temperature based on colorimetric temperature measurement[J]. Automation & Instrumentation, 2010, (9): 5-8.

[12] 原遵东. 消除背景辐射影响的辐射源尺寸效应测量模型[J]. 光学学报, 2011, 31(12): 1212002.

    Yuan Zundong. A new background radiation-balanced model for the size of source effect measurement[J]. Acta Optica Sinica, 2011, 31(12): 1212002.

闫白, 郝晓剑, 周汉昌. 基于比色法的纯镁及镁合金燃点测试系统[J]. 激光与光电子学进展, 2013, 50(11): 112301. Yan Bai, Hao Xiaojian, Zhou Hanchang. Ignition Test System of Pure Magnesium and Magnesium Alloys Based on Colorimetric Method[J]. Laser & Optoelectronics Progress, 2013, 50(11): 112301.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!