激光与光电子学进展, 2015, 52 (8): 080006, 网络出版: 2015-07-29   

CT造影冠状动脉狭窄检测与量化的相关研究 下载: 958次

Research on Stenosis Detection and Quantification of Coronary Artery in CT Angiography
作者单位
1 河南大学计算机与信息工程学院, 河南 开封 475000
2 河南大学图像处理与模式识别研究所, 河南 开封 475000
摘要
心血管疾病与冠状动脉狭窄之间有着密切的联系,对冠状动脉狭窄的检测和量化对心血管疾病的预防、发现和诊断具有重要的意义.随着医学成像手段及图像处理技术的进步,通过在冠状动脉计算机断层扫描造影(CTA)中应用自动冠状动脉树标记、血管追踪以及稳健核回归等技术,自动/半自动狭窄检测及量化已成为重要的医学图像处理发展方向.回顾了近年来在冠状动脉狭窄检测及量化领域的最新进展,总结了狭窄检测及量化的流程,讨论了未来狭窄检测及量化的发展趋势和临床应用前景.
Abstract
Cardiovascular disease and coronary artery stenosis are closely related.Detection and quantification of coronary artery stenosis is important for cardiovascular disease prevention,detection and diagnosis.As the rapid growth of medical imaging and image processing techniques,automatic and semi-automatic stenosis detection,as well as quantification,has become an important development direction in the field of medical image processing.The related technologies include automatic coronary artery tree labeling on computed tomography angiography (CTA),vessel tractography,and robust kernel regression,etc.The latest advance in coronary artery stenosis detection and quantification in the recent years is reviewed,the technological process of stenosis detection is summarized,and the tendency and application prospect in the future is discussed.
参考文献

[1] Akinyemi A,Murphy S,Poole I,et al..Automatic labeling of coronary arteries[C].17th European Signal Processing Conference,2009:1562-1566.

[2] Yang G,Broersen A,Petr R,et al..Automatic coronary artery tree labeling in coronary computed tomographic angiography datasets[C].IEEE Computing in Cardiology,2011:109-112.

[3] Metz C T,Schaap M,Weustink A C,et al..Coronary centerline extraction from CT coronary angiography images using a minimum cost path approach[J].Medical Physics,2009,36(12):5568-5579.

[4] 张朝霞,陈晓冬,单建丰,等.基于多层螺旋CT 血管分析的感兴趣冠脉段最佳造影角度计算[J].中国激光,2011,38(11):1104003.

    Zhang Zhaoxia,Chen Xiaodong,Shan Jianfeng,et al..Calculation of optimal angiographic angle for segment of interest based on multislice computed tomography vessel analysis[J].Chinese J Lasers,2011,38(11):1104003.

[5] 肖若秀,杨健,宋凌,等.应用于医学三维影像的血管结构自动提取[J].光学精密工程,2014,22(2):443-450.

    Xiao Ruoxiu,Yang Jian,Song Ling,et al..Automatic blood vessel extraction for CTA images.Optics and Precision Engineering,2014,22(2):443-450.

[6] Cetin S,Demir A,Yezzi A,et al..Vessel tractography using an intensity based tensor model with branch detection[J].IEEE Transactions on Medical Imaging,2013,32(2):348-363.

[7] Schaap M,Neefjes L,Metz C,et al..Coronary lumen segmentation using graph cuts and robust kernel regression[J].Information Processing in Medical Imaging,2009,21:528-539.

[8] Duval M,Ouzeau E,Precioso F,et al..Coronary artery stenoses detection with random forest[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[9] Eslami A,Aboee A,Hodaei Z,et al..Quantification of coronary arterial stenosis by inflating tubes in CT angiographic images[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation,2012.

[10] Kiri li H A,Schaap M,Metz C T,et al..Standardized evaluation framework for evaluating coronary artery stenosis detection,stenosis quantification and lumen segmentation algorithms in computed tomography angiography[J].Medical Image Analysis,2013,17(8):859-876.

[11] Broersen A,Kitslaar P,Frenay M,et al..FrenchCoast:Fast,robust extraction for the nice challenge on coronary artery segmentation of the tree[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[12] Yang G,Kitslaar P,Frenay M,et al..Automatic centerline extraction of coronary arteries in coronary computed tomographic angiography[J].International Journal of Cardiovascular Imaging,2012,28(4):921-933.

[13] Boogers M J,Broersen A,van Velzen J E,et al..Automated quantification of coronary plaque with computed tomography:Comparison with intravascular ultrasound using a dedicated registration algorithm for fusion- based quantification[J].European Heart Journal,2012,33(8):1007-1016.

[14] Cetin S,Unal G.Automatic detection of coronary artery stenosis in CTA based on vessel intensity and geometric features [C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[15] Goldenberg R,Eilot D,Begelman G,et al..Computer-aided simple triage (CAST) for coronary CT angiography (CCTA)[J].International Journal of Computer Assisted Radiology and Surgery,2012,7(6):819-827.

[16] Goldenberg R,Peled N.Computer- aided simple triage[J].International Journal of Computer Assisted Radiology and Surgery,2011,6(5):705-711.

[17] Flórez V L,Orkisz M,Corredor R A,et al..Coronary artery segmentation and stenosis quantification in CT images with use of a right generalized cylinder model[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[18] Gülsün M A,Tek H.Robust vessel tree modeling[C].Medical Image Computing and Computer- Assisted Intervention-MICCAI 2008,2008:602-611.

[19] Milwer M B,Valencia L F,Hoyos M H,et al..Fast- marching contours for the segmentation of vessel lumen in CTA cross- sections[C].29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society,2007:791-794.

[20] Lor K,Chen C.Probabilistic model based evaluation of coronary artery stenosis on CTA[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[21] Melki I,Talbot H,Cousty J,et al..Automatic coronary arteries stenoses detection in 3D CT angiography[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[22] Mohr B,Masood S,Plakas C.Accurate lumen segmentation and stenosis detection and quantification in coronary CTA [C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[23] Schaap M,Metz C T,van Walsum T,et al..Standardized evaluation methodology and reference database for evaluating coronary artery centerline extraction algorithms[J].Medical Image Analysis,2009,13(5):701-714.

[24] Shahzad R,van Walsum T,Kiri li H,et al..Automatic detection,quantification and lumen segmentation of the coronary arteries using two-point centerline extraction scheme[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

[25] Wang C,Moreno R,Smedby .Vessel segmentation using implicit model-guided level sets[C].Proceedings of MICCAI Workshop 3D Cardiovascular Imaging:A MICCAI Segmentation Challenge,2012.

陈相廷, 张帆, 张一凡, 孔珊. CT造影冠状动脉狭窄检测与量化的相关研究[J]. 激光与光电子学进展, 2015, 52(8): 080006. Chen Xiangting, Zhang Fan, Zhang Yifan, Kong Shan. Research on Stenosis Detection and Quantification of Coronary Artery in CT Angiography[J]. Laser & Optoelectronics Progress, 2015, 52(8): 080006.

本文已被 3 篇论文引用