Multi-channel polarized low-coherence interference synchronous demodulation system based on a matrix charge-coupled device Download: 774次
Shuang Wang 1,2,3,*Jie Zhou 1,2,3Junfeng Jiang 1,2,3,**Kun Liu 1,2,3Qun Han 1,2,3Yanan Duan 1,2,3Rundong Wang 1,2,3Tiegen Liu 1,2,3
1 School of Precision Instrument and Opto-electronics Engineering, Tianjin University, Tianjin 300072, China
2 Key Laboratory of Opto-electronics Information Technology, Ministry of Education, Tianjin 300072, China
3 Tianjin Optical Fiber Sensing Engineering Center, Institute of Optical Fiber Sensing of Tianjin University, Tianjin 300072, China
Figures & Tables
Fig. 1. Schematic diagram of the polarized multi-channel synchronous demodulation system.
下载图片 查看原文
Fig. 2. Schematic diagram of the horizontal section optical path analysis.
下载图片 查看原文
Fig. 3. Interferograms of four channels detected by the matrix CCD when the air pressure is 101 kPa.
下载图片 查看原文
Fig. 4. Signals of channels 1–4 when the air pressure is 101 kPa.
下载图片 查看原文
Fig. 5. Relationship between the absolute phase and the corresponding air pressure of the four channels.
下载图片 查看原文
Fig. 6. Pressure errors and standard deviations of channels 1–4 within the air pressure measuring range.
下载图片 查看原文
Shuang Wang, Jie Zhou, Junfeng Jiang, Kun Liu, Qun Han, Yanan Duan, Rundong Wang, Tiegen Liu. Multi-channel polarized low-coherence interference synchronous demodulation system based on a matrix charge-coupled device[J]. Chinese Optics Letters, 2020, 18(7): 071202.