强激光与粒子束, 2007, 19 (8): 1365, 网络出版: 2008-02-18   

单线法测量横向阻抗系统设计与模拟计算

Design of transverse impedance measurement setup and wire method simulation
作者单位
中国科学技术大学,国家同步辐射实验室,合肥,230029
摘要
介绍了单线法测量横向阻抗的基本原理、系统设计和初步模拟计算结果.单线法横向阻抗测量系统由待测元件/参考元件、内置导线、导线偏移调节机构、阻抗匹配段和测量仪器构成.调节机构可以精确调整内置导线的横向位置以激励偶极模式.利用微波工作室软件模拟计算待测元件(2 856 MHz"凸型"腔)的偶极模."凸型"腔横向阻抗的幅值和偶极模频率的计算结果与ABCI程序数值计算的结果基本相符,说明了单线法横向阻抗测量系统理论上的可行性.
Abstract
参考文献

[1] Baboi N.Wire measurement of impedance of an X-band accelerating structure[R].SLAC-PUB-10685,2004.

[2] Vaccaro V G.Coupling impedance measurements:an improved wire method[R].INFN/TC-94/023,1994.

[3] Chao A W.Physics of collective instabilities in high energy accelerators[M].New York:John Wiley and Sons Inc,1993.

[4] Pulumbo L,Vaccaro V G,Zobov M.Wake fields and impedances[R].CERN95-06,GENEVA,CERN,1995:331-351.

[5] Baboi N.Measuring impedances in the NLC accelerating structures with wire method[R].NLC Meeting,USA,2002.

[6] Baboi N.Coaxial wire measurements in NLC accelerating structures[R].SLAC-PUB-9248,2002.

[7] 王琳,徐宏亮,冯光耀.同轴线方法测量束流耦合阻抗的有效性分析[J].强激光与粒子束,2002,14(6):920-924.(Wang L,Xu H L,Feng G Y.Validity of coaxial wire method in impedance measurement.High Power Laser and Particle Beams,2002,14(6):920-924)

常利敏, 王琳, 李为民. 单线法测量横向阻抗系统设计与模拟计算[J]. 强激光与粒子束, 2007, 19(8): 1365. 常利敏, 王琳, 李为民. Design of transverse impedance measurement setup and wire method simulation[J]. High Power Laser and Particle Beams, 2007, 19(8): 1365.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网