High Power Laser Science and Engineering, 2016, 4 (1): 010000e2, Published Online: Oct. 25, 2016  

Hard x-ray transmission curved crystal spectrometers (10–100 keV) for laser fusion experiments at the ShenGuang-III laser facility Download: 828次

Author Affiliations
1 Department of Modern Physics & CAS Key Laboratory of Geospace Environment, University of Science and Technology of China, Hefei, Anhui 230026, China
2 Research Center of Laser Fusion, China Academy of Engineering Physics, Mianyang 621900, China
3 National Synchrotron Radiation Laboratory, University of Science and Technology of China, Hefei, Anhui 230026, China
Figures & Tables

Fig. 1. Cauchois-geometry optics of a symmetry transmission cylindrical curved crystal.

下载图片 查看原文

Fig. 2. (Solid lines) the position of the slit $f$ versus the detecting distance $s$ (the source-to-crystal distance) of the 17.48 keV Mo K${\it\alpha}_{1}$ x-ray. (Dash lines) the position of the slit $f$ versus the x-ray photon energy at a fixed detecting distance, $s$, of 500 mm. The crystals’ curvature radii are 150 and 300 mm.

下载图片 查看原文

Fig. 3. The lateral distance of the 10 keV x-ray footprint on the crystal (Point C in Figure 1) versus the crystal’s curvature radius. The detecting distances $s$ are 200 mm (dash line) and 1500 mm (solid line).

下载图片 查看原文

Fig. 4. Theoretical spectral sensitivities of the transmission curved crystal spectrometers LCCS and HCCS. Insert is the sensitivity curve of Fujifilm™ image plates SR.

下载图片 查看原文

Fig. 5. Spectral resolution of the LCCS and HCCS spectrometers at detecting distances of 200 and 1500 mm. The working distance of the recording medium is fixed at $d_{0}=22~\text{mm}$.

下载图片 查看原文

Fig. 6. The energy-dependent integrated reflectivity of the curved crystals. The ${\it\alpha}$-quartz (10–11) crystals’ curvature radii are 300 mm (HCCS) and 150 mm (LCCS).

下载图片 查看原文

Fig. 7. Schematic diagram of the HCCS spectrometer.

下载图片 查看原文

Fig. 8. Experimental spectral images of a Mo anode x-ray source measured by (a) LCCS and (b) HCCS. Details of K lines are shown in (c) and (d), for LCCS and HCCS, respectively. The exposure times are 60 s for LCCS and 30 s for HCCS.

下载图片 查看原文

Fig. 9. Spectral images of the Mo anode x-ray source obtained by LCCS with various working distances $d_{\text{0}}$. (a) $d_{\text{0}}=7~\text{mm}$; (b) $d_{\text{0}}=22~\text{mm}$; (c) $d_{\text{0}}=52~\text{mm}$. The abscissa represents the distance from the left side of image.

下载图片 查看原文

Fig. 10. Experimentally measured and theoretically calculated spectral resolution at various working distances.

下载图片 查看原文

Fig. 11. Ag spectral images recorded using the HCCS at the XGIII laser facility (a), the detail characteristic K lines of Ag (b, c).

下载图片 查看原文

Table1. Design parameters of the Curved Crystal Spectrometers (CCS).

LCCS HCCS
Crystal${\it\alpha}$-quartz (10–11) 70 mm ($L$) $\times$ 12 mm ($W$) $\times$ 0.27 mm ($T$)
Curvature radius (mm) 150 300
Energy range (keV) 10–56 17–100
Detecting distance (mm)200–1500 200–1500
Resolution $(E/{\rm\Delta}E)$331-57327-54
Recording mediumFujifilm BAS-SR IPs 74 mm ($L$) $\times$ 20 mm ($W$)

查看原文

Ming-hai Yu, Guang-yue Hu, Ning An, Feng Qian, Yu-chi Wu, Xiao-ding Zhang, Yu-qiu Gu, Qiu-ping Wang, Jian Zheng. Hard x-ray transmission curved crystal spectrometers (10–100 keV) for laser fusion experiments at the ShenGuang-III laser facility[J]. High Power Laser Science and Engineering, 2016, 4(1): 010000e2.