大气与环境光学学报, 2017, 12 (4): 283, 网络出版: 2017-08-09   

基于相关光子宽谱段自校准辐射基准源的定标新方法

Noval Calibration Method for Self-Calibration and Wide Spectral Band Radiation Reference Source Based on Correlated Photon
作者单位
中国科学院安徽光学精密机械研究所 中国科学院通用光学定标与表征技术重点实验室, 安徽 合肥 230031
摘要
针对我国空间科学的未来发展和应用需求,以及目前星上定标和在轨定标方法的局限性,提出一种基于自发参量下转换效应的自校准宽谱段(450~1500 nm) 辐射基准源设计方案。该辐射基准源系统主要由宽波段参量下转换、观测与自校准复用光路、多路光子计数与符合探测、信号采集与 测量控制等4个主要功能模块构成。辐射基准源兼有星上自校准和自主观测功能,能够在不依赖于外部基准的条件下实现高精度的自校准,保障对 地高精度观测,为其他卫星有效载荷提供高精度的量值传递标准。
Abstract
For the future development and application requirements of our country’s space science and the limitations of the present satellite calibration and orbit calibration method, a design scheme of self-calibration and wide spectral band (450~1500 nm) radiation reference source is proposed. The radiation reference source is based on spontaneous parametric down-conversion effect. It is mainly composed of four main modules. They are wide spectral band parametric down-conversion, observation and self-calibration multiplexing optical path, multi-channel photon counting and coincidence detection, signal acquisition and measurement control. The radiation reference source has the function of self-calibration and self-observation. It can realize the high precision observation of the earth through its own absolute self-calibration function without external reference. This can provide high accuracy value transfer standard for other satellite payload.
参考文献

[1] Louisell W H, Yariv A, Siegman A E. Quantum fluctuations and noise in parametric processes. I.[J].Phys. Rev., 1961, 124(6): 1646-1654.

[2] Klyshko D N. Use of two-photon light for absolute calibration of photoelectric detectors[J].Sov. J. Quantum Electron., 1980, 10(9): 1112-1116.

[3] Ghazi-Bellouati A, Razeta A, Bastie J,et al. Detector calibration at INM using a correlated photons source[J].Eur. Phys. J. Appl. Phys., 2006, 35(3): 211-216.

[4] Brida G, Castelletto S, Novro C.Measurement of quantum efficiency of photodetectors by parametric fluorescence[J].Metrologia, 1998, 35(4): 379-401.

[5] Cheung J Y, Chunnilall C J, Thomas P J,et al. Photon-counting measurement challenges[C]. Proc. SPIE, 2007, 6583: 65830G1-65830G12.

[6] Migdall A L, Datla R U, Sergienko A,et al. Absolute detector quantum-efficiency measurements using correlated photons[J]. Metrologia, 1995, 32(6): 479-483.

[7] Feng Y, Zheng X B, Li J J,et al. Research in absolute calibration of single photon detectors by means of correlated photons[J]. Chin. Opt. Lett., 2000, 4(6): 315-317.

[8] Li J J, Zheng X B, Lu Y J,et al. Quantum efficiency calibration of opto-electronic detector by means of correlated photons method[J]. Chin. Opt. Lett., 2008, 6(7): 472-475.

[9] Polyakov S V, Migdall A L. High accuracy verification of a correlated photon-based method for determining photon-counting detection efficiency[J].Opt. Exp., 2007, 15(4): 1390-1404.

[10] 吕 亮,张寅超, 林延东.纠缠光子法绝对定标光电探测器量子效率的研究[J]. 光学学报, 2012, 32(1): 0112004.

    Lü Liang, Zhang Yinchao, Lin Yandong. Research on absolute calibration of photodetector quantum-efficiency using entangled photons[J].Actra Optica Sinica, 2012, 32(1): 0112004(in Chinese).

[11] Klyshko D N.Photons and Nonlinear Optics[M]. New York: Gordon and Breach, 1988.

刘岩, 李健军, 夏茂鹏, 高冬阳, 胡友勃, 郭园园, 郑小兵, 闫静. 基于相关光子宽谱段自校准辐射基准源的定标新方法[J]. 大气与环境光学学报, 2017, 12(4): 283. LIU Yan, LI Jianjun, XIA Maopeng, GAO Dongyang, HU Youbo, GUO Yuanyuan, ZHENG Xiaobing, YAN Jing. Noval Calibration Method for Self-Calibration and Wide Spectral Band Radiation Reference Source Based on Correlated Photon[J]. Journal of Atmospheric and Environmental Optics, 2017, 12(4): 283.