Chinese Optics Letters, 2003, 1 (8): 08459, Published Online: Jun. 6, 2006
A new method for angular displacement measurement Download: 745次
Abstract
We describe a new method for angular displacement measurements that is based on a Fabry-Perot interferometer. A measurement accuracy of 10^(-8) rad is obtained by use of the sinusoidal phase modulating interferometry. Another Fabry-Perot interferometer is used to obtain the key initial angle of incidence.
References
[1] D. Malacara and O. Harris, Appl. Opt. 9, 1630 (1970).
[2] C. Chien, J. Shyu, Y. Huang, and C. Yuan, Appl. Opt. 37, 4137 (1998).
[3] E. Dalhoff, R. G¨artner, U. Hofbauer, H. Tiziani, H.-P. Zenner, and A. W. Gummer, J. Modern Optics 45, 765 (1998).
[4] M. Vaez-Iravani, M. Nonnenmacher, and H. K. Wickramasinghe, Opt. Eng. 32, 1879 (1993).
[5] O. Sasaki and H. Okazaki, Appl. Opt. 25, 3152 (1986).
[6] O. Sasaki, H. Okazaki, and M. Sakai, Appl. Opt. 26, 1089 (1987).
Caini Zhang, Xiangzhao Wang. A new method for angular displacement measurement[J]. Chinese Optics Letters, 2003, 1(8): 08459.