光电子快报(英文版), 2013, 9 (5): 329, Published Online: Oct. 12, 2017  

Study on calibration method for the performance index of SPR sensors

Author Affiliations
Department of Optical Engineering, Zhejiang University, Hangzhou 310057, China
Abstract
Aiming at the problem that there isn’t any standardized calibration method for the performance index of surface plasmon resonance (SPR) sensor, the calibration method for key performance indices of SPR sensor is summarized and proposed based on the comparison of relative methods and definition of each index. Experimental data of sucrose solutions with various concentrations are obtained by the self-building SPR instrument, and then the calibration method is used to determine the performance indices, such as noise, drift, sensitivity, resolution, linearity, dynamic range and reproducibility. Experimental results show that the definition of indices is reasonable, and the calibration method is correct, which has great significance for performance evaluation of SPR sensor.
References

[1] J. Homola, Chemical Reviews 108, 462 (2008).

[2] J. Homola, Surface Plasmon Resonance Based Sensors, Springer Verlag, Berlin, 2006.

[3] C. L. Wong, G. C. K. Chen, X. Li, B. K. Ng, P. Shum, P. Chen, Z. Lin, C. Lin and M. Olivo, Biosensors and Bioelectronics 47, 545 (2013).

[4] J. Liu, B. X. Chen and H. M. Yang, Journal of Optoelectronics ·Laser 22, 1821 (2011). (in Chinese)

[5] W. Zhang, H. Sun, R. P. Liu, Z. Yue, C. Wang, S. J. Chang, W. D. Geng and G. H. Liu, Journal of Optoelectronics·Laser 23, 1005 (2012). (in Chinese)

[6] T. M. Chinowsky, M. S. Grow, K. S. Johnston, K. Nelson, T. Edwards, E. Fu and P. Yager, Biosensors and Bioelectronics 22, 2208 (2007).

[7] T. M. Chinowsky, S. D. Soelberg, P. Baker, N. R. Swanson, K. Peter, A. Mactutis, M. S. Grow, R. Atmar, S. S. Yee and C. E. Furlong, Biosensors and Bioelectronics 22, 2268 (2007).

[8] G. D. VanWiggeren, M. A. Bynum, J. P. Ertel, S. Jefferson, K. M. Robotti, E. P. Thrush, D. M. Baney and K. P. Killeen, Sensors and Actuators B: Chemical 127, 341 (2007).

[9] S. Y. Zhan, X. P. Wang and Y. L. Liu, Measurement Science and Technology 22, 025201 (2011).

[10] A. Giorgini, S. Avino, P. Malara, G. Gagliardi, M. Casalino, G. Coppola, M. Iodice, P. Adam, K. Chadt, J. Homola and P. De Natale, Optics Letters 38, 1951 (2013).

[11] F. Bardin, A. Bellemain, G. Roger and M. Canva, Biosensors & Bioelectronics 24, 2100 (2009).

[12] M. Naya, N. Mori, T. Kimura, H. Ohtsuka, T. Kubo, H. Shimizu, M. Naya, N. Mori, T. Kimura, H. Ohtsuka, T. Kubo and H. Shimizu, Journal of Nanophotonics 1, 011596 (2007).

[13] K. Hegnerová, M. Piliarik, M. Steinbachová, Z. Flegelová, H. Cernohorskáand and J. Homola, Analytical and Bioanalytical Chemistry 398, 1963 (2010).

[14] X. T. Zhang, Z. H. Yun and R. N. Fu, HPLC Measure Method, Chemical Industry Press, Beijing, 2000. (in Chinese)

[15] Y. B. Shin, H. M. Kim, Y. Jung and B. H. Chung, Sensors and Actuators B: Chemical 150, 1 (2010).

[16] I. R. Hooper, M. Rooth and J. R. Sambles, Biosensors and Bioelectronics 25, 411 (2009).

[17] B. Q. Yang, Fundamental of Modern Sensors, China Railway Publishing House, Beijing, 2001. (in Chinese)

[18] L. C. Oliveira, C. S. Moreira, C. Thirstrup and E. U. K. Melcher, Instrumentation and Measurement 65, 1223 (2013).

[19] T. Ghosh and C. H. Mastrangelo, Analyst 137, 2381 (2012).

[20] J. Chen, Y. Chen, J. Xu, Y. Zhang and T. Liao, Chemometrics and Intelligent Laboratory Systems 114, 56 (2012).

[21] S. Zhan, X. Wang, Z. Luo, H. Zhou, H. Chen and Y. Liu, Sensors and Actuators B: Chemical 153, 427 (2010).

HUANG Zi-hao, HONG Xia-yun, DONG Lian-hong, ZHAN Shu-yue, WANG Xiao-ping, LIU Xu. Study on calibration method for the performance index of SPR sensors[J]. 光电子快报(英文版), 2013, 9(5): 329.