论述了自行研制的偏振干涉成像光谱仪的剪切分光机理和干涉成像原理。对偏振干涉成像光谱仪的通量进行了分析和计算,推导了偏振器偏振化方向偏离理想方向时通量随偏角的变化关系,给出了最大调制度情形下的通量数值。这种偏振干涉成像光谱仪结构简单、无运动部件、能量通过率高,充分显示了超小型、稳态、大视场、高通量、高调制度的优点,更加适合于航空航天遥感、野外环境操作和微弱信号探测。
Abstract
Shearing and imaging principle of the polarization interference imaging spectrometer (PIIS) are presented. Throughput of the PIIS is analyzed and calculated, the changing relation of throughput with deviation is derived under polarizer's polarized direction deviating from the ideal direction. Throughput value in the maximum modulation depth is given. The PIIS has simple structure and no moving parts, high pass through rate of energy. It shows the advantages of ultra-compact, stationary, wide view of field, high throughput and modulation depth. It is more suitable for remote sensing of aviation and aerospace, field operation and weak signal detection.
参考文献

[1] Bell R J. Introductory Fourier Transform Spectroscopy. New York: Academic, 1972. ~

[2] Persky M J. A review of spaceborne Fourier transform spectrometer for remote sensing. Rev. Sci. Instrum., 1995, 66(10):4763~4793

[3] Vaughan A H. Imaging Michelson spectrometer for Hubble space telescopy. Proc. SPIE, 1988, 1036:2~14

[4] Junttila M L, Kauppinen J, Ikonen E. Performance limits of stationary Fourier transform spec trometers. J. Opt. Soc. Am. (A), 1991, 8(9):1457~1462

[5] Junttila M L. Stationary Fourier transform spectrometer. Appl. Opt., 1992, 31(21):4106~4112

[6] M ller K D. Wave-front-dividing array interferometer without moving parts for real-time spectroscopy from the IR to the UV. Appl. Opt., 1995, 34(9):1493~1501

[7] 张淳民,王 炜,相里斌等.利用干涉成像光谱技术测量大气风场. 光学学报,2000,20(2):243~249

[8] 张淳民,赵葆常,相里斌. 高稳态大视场大气风场测量新方法. 光学学报,2000,20(5):697~700

[9] 张淳民,相里斌,赵藻常. 用法布里-珀罗干涉仪(FPI)测量上层大气风场的速度和温度. 西安交通大学学报,2000,34(4):97~99

[10] Rafert J B, Sellar R G, Blatt J H. Monolithc Fourier transform imaging spectrometer. Appl. Opt., 1995, 34(31):7228~7230

[11] Courtial J, Patterson B A, Harvey A R et al.. Design of a static Fourier-transform spectrometer with increased field of view. Appl. Opt., 1996, 35(34):6698~6702

[12] Patterson B A, Antoni M, Courtial J et al.. An ultra-compact static Fourier-transform spectrometer based on a single birefringent component. Opt. Commun., 1996, 130(1~3):1~6

[13] Francon M, Mallick S. Polarization Interferometers, New York: Wiley, 1971. 22~23, 144~145

[14] 李景镇主编.光学手册. 西安: 陕西科技出版社,1985, 491~492

[15] 张淳民,赵葆常,相里斌.偏振干涉成像光谱仪中偏振化方向对调制度的影响. 光学学报,2000,20(8):1077~1083

张淳民, 赵葆常, 相里斌, 杨建峰. 偏振干涉成像光谱仪通量的分析与计算[J]. 光学学报, 2001, 21(2): 192. 张淳民, 赵葆常, 相里斌, 杨建峰. Analysis and Calculation of Throughput of the Polarization Interference Imaging Spectrometer[J]. Acta Optica Sinica, 2001, 21(2): 192.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!