光学学报, 2007, 27 (10): 1842, 网络出版: 2007-10-24   

采用非线性相位拟合法设计长焦深透镜

Long-Focal-Depth Lens Designed by Nonlinear Phase Fitting Method
作者单位
1 中国工程物理研究院激光聚变研究中心, 绵阳 621900
2 四川大学物理系科学与技术学院, 成都 610064
摘要
针对惯性约束聚变(ICF)激光等离子体诊断系统应用的需求,提出一种采用非线性相位拟合法设计单透镜代替理想对数轴锥镜的方法。对所要得到的球面透镜与理想对数轴锥镜的相位进行拟合,求解得出所需要的球面透镜参量。设计了用于激光等离子体诊断系统的长焦深透镜,并对透镜的焦深、轴向光场均匀性、横向均匀性、焦斑旁瓣等指标进行分析。数值分析结果表明,长焦深透镜具有与理想对数轴锥镜相同的相位分布,焦深、轴向光场均匀性、横向均匀性、焦斑旁瓣均符合设计要求,验证了非线性相位拟合法的正确性。
Abstract
For requriement of plasma diagnostic system in inertial confinement fusion (ICF) drivers, simple lens which can be substituted for logarithmic axicon is designed by nonlinear-phase fitting method. Required sperhical lens parameters are determined by fitting the phase of sperhical lens and logarithmic axicon. A long-focal-depth lens applied for plasma diagnostic system is designed, and the optical performance of lens is analyzed, such as long focal depth, homogeneous axial , transverse intensity distribution and side lobe of focal spot. Numerical results show that long-focal-depth lens has the same phase distribution with logarithmic axicon, its optical performance can satisfy the requirements of plasma diagnostic system, so the nonlinear phase fitting method is valid.
参考文献

[1] . H. McLeod. The axicon: a new type optical element[J]. J. Opt. Soc. Am. A, 1954, 44(8): 592-597.

[2] . Durnin, J. J. Miceli, J. H. Eberly. Diffraction-free beams[J]. Phy. Rev. Lett., 1987, 58(15): 1499-1501.

[3] . Davidson, A. A. Friesem, E. Hasman. Holographic axicon: High resolution and long focal depth[J]. Opt. Lett., 1991, 16(7): 523-525.

[4] . Sochachi , S. Bar, Z. Jaroszewicz et al.. Phase retardation of the uniform-intensity axilens[J]. Opt. Lett., 1992, 17(1): 7-9.

[5] . Jaroszewicz, J. Sochacki, A. Kolodziejczyk et al.. Apodized annular-aperture logarithmic axicon: smoothness and uniformity of intensity distributions[J]. Opt. Lett., 1993, 18(22): 1893-1895.

[6] . Jaroszewicz, J. Morales. Lens axicons: systems composed of a diverging aberrated lens and a perfect converging lens[J]. J. Opt. Soc. Am. A, 1998, 15(9): 2383-2390.

[7] . Burvall, K. Kolacz, Z. Jaroszewicz et al.. Simple lens axicon[J]. Appl. Opt., 2004, 43(25): 4838-4844.

[8] Shenglin Wen, Yongkang Guo, Jingqin Su et al.. Design and optimization of an axicon used for plasma diagnostic system in ICF drivers[C]. Proc. SPIE, 2006, 6290: 62900U-1~62900U-7

粟敬钦, 温圣林, 袁静, 刘兰琴, 王文义, 高福华. 采用非线性相位拟合法设计长焦深透镜[J]. 光学学报, 2007, 27(10): 1842. 粟敬钦, 温圣林, 袁静, 刘兰琴, 王文义, 高福华. Long-Focal-Depth Lens Designed by Nonlinear Phase Fitting Method[J]. Acta Optica Sinica, 2007, 27(10): 1842.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote