摘要
利用拉曼光场代替喷泉原子钟的微波腔实现拉曼喷泉原子钟。将分离拉曼光场技术与冷原子喷泉技术相结合,避免了在真空腔内放置微波腔,简化了真空系统,同时还保持了很高的准确度。采用半经典理论研究了冷原子喷泉与拉曼光场的相互作用过程,得到了冉赛(Ramsey)条纹。比较了拉曼喷泉原子钟与热铯束拉曼原子钟,前者有更小的体积和功耗,其精度可能达到或超过商用小铯钟。还比较了拉曼喷泉原子钟与微波喷泉原子钟的差别,分析了光子反冲的影响,提出利用同向传播和相向传播的两台拉曼原子钟测量精细结构常数。
Abstract
An atomic fountain clock based on Raman laser field instead of microwave cavity is proposed. This scheme combines the separate Raman fields technology and the cold atomic fountain technology, cancels the microwave fountain clock in the vacuum cavity and meanwhile keeps a high accuracy.The interaction process of the cold atomic fountain and the Raman laser field is studied with the semiclassical theory and the Ramsey fringes are acquired. The Raman fountain clock is compared with the atomic beam clock of hot cesium atoms, and it is found that the accuracy of Raman fountain clock higher and its capacity and power consumption are much smaller. Compared with the microwave fountain clock, the Raman fountain clock must consider the influence of photon recoil. With the photon recoil, it is proposed to measure the fine structure constant by using two Raman fountain clocks.
参考文献

[1] B. Y. Huang. New Generation Atomic Clocks[M]. Wuhan: Wuhan University Press, 2006. 23
黄秉英. 新一代原子钟[M]. 武汉: 武汉大学出版社, 2006. 23

[2] . Clairon, C. Salomon, S. Guellati. Ramsey resonance in a Zacharias fountain[J]. Europhys. Lett., 1991, 16(2): 165-170.

[3] . Lett, Richard N. watts, Christoph I. Westbrook et al.. Observation of atoms laser cooled below the Doppler limit[J]. Phys. Rev. Lett., 1988, 61(2): 169-172.

[4] . Clarion, P. Laurent, G. Stantarelli et al.. A cesium fountain frequency standard: preliminary results[J]. IEEE Trans. on Inst. And Meas., 1995, 44(2): 128-131.

[5] . Experimental verification of the shift of the cesium hyperfine transition frequency due to blackbody radiation[J]. Phys. Rev. Lett., 1997, 78(4): 622-625.

[6] Christophs Salomon, Christian Veillet. ACES: atomic clock ensemble in space[J]. ESA Space Station Utilization Symposium, Darmstadt 1996, SP-385 295~297

[7] . Laser-cooled microgravity clocks[J]. IEEE Int. Freq. Control Symp., 1998, 52: 41-45.

[8] . G. Robinson, S. R. Jefferts, D. B. Sullivan. Design studies for a laser-cooled space clock[J]. IEEE Int. Freq. Control Symp., 1998, 52: 37-40.

[9] T. C. Li, M. S. Li, P. W. Lin et al.. Improvement and evaluation of the NIM4 cesium atomic fountain clock[C]. Convention Thesis of the National Time Frequency Science Conference, 2005
李天初,李明寿,林平卫 等. 2005年NIM4铯喷泉钟的改进和最新评估[C]. 2005年全国时间频率学术交流会论文集, 2005

[10] R. Wei, T. Li, F G. Bian et al.. The progress of the cold atomic clock in Shanghai Institute of Optics and Fine Mechanics[C]. Convention Thesis of the National Time Frequency Science Conference, 2005
魏荣,李唐,边风刚 等. 上海光机所冷原子钟研究的进展[C]. 2005年全国时间频率学术交流会论文集, 2005

[11] F. G. Bian. The design of minitype 87Rb atomic fountain clock and space cold atomic clock[D]. Shanghai Institute of Optics and Fine Mechanics,2006
边风刚. 小喷泉87Rb原子钟的设计与空间冷原子钟的研究[D]. 上海: 上海光学精密机械研究所, 2006

[12] R. Wei. The design of minitype 87Rb atomic fountain clock and work in the earlier stage[D]. Shanghai Institute of Optics and Fine Mechanics, 2003
魏荣. 小型喷泉铷原子钟的设计与前期工作[D]. 上海: 上海光学精密机械研究所, 2003

[13] . E. Thomas, S. Ezekiel. Ultrahigh-resolution spectroscopy and frequency standards in the microwave and far-infrared regions using optical lasers[J]. Opt. Lett., 1981, 6(6): 298-300.

[14] . E. Thomas, P. R. Hemmer, S. Ezekiel et al.. Observation of Ramsey fringes using a stimulated, resonance Raman transition in a sodium atomic beam[J]. Phys. Rev. Lett., 1982, 48(13): 867-870.

[15] . Peters, K. Y. Chung, S. Chu. High-precision gravity measurements using atom interferometry[J]. Metrologia, 2001, 38(1): 25-61.

[16] . Weiss, Manc Kasevich et al.. Theoretical analysis of velocity-selective Raman transitions[J]. Phys. Rev. A, 1992, 45(1): 342-348.

[17] . Weiss, Brenton C. Young, Steven Chu. Precision measurement of the photon recoil of an atom using atomic interferometry[J]. Phys. Rev. Lett., 1993, 70(18): 2706-2709.

[18] D. S. Weiss, B. C. Young, S. Chu. Precision measurement of /mCs based on photon recoil using laser-cooled atoms and atomic interferometry[J]. Appl. Phys., 1994, B59(3): 217~253

屈求智, 周子超, 万金银, 刘亮. 拉曼喷泉原子钟[J]. 光学学报, 2008, 28(7): 1390. Qu Qiuzhi, Zhou Zichao, Wan Jinyin, Liu Liang. Raman Atomic Fountain Clock[J]. Acta Optica Sinica, 2008, 28(7): 1390.