光子学报, 2008, 37 (5): 1029, 网络出版: 2008-08-19   

外场多光轴瞄准偏差测试的基准光轴建立方法

Setup of Reference Optical Axis for Aiming Deviation Evaluation with Multi-optical Axis in Field
作者单位
1 西安电子科技大学,理学院,西安,710071
2 西安工业大学,光电工程学院,西安,710032
摘要
提出一种针对外场真实环境下可见光、激光和红外多光轴瞄准系统瞄准偏差测试的基准光轴建立方法.采用精密大地测距、测角技术获得观测仪器站址坐标、基准光轴方向和靶标中心位置,通过对标定靶标上的中心点作测距和测角观测,并对基准光轴方向大气折射和地球曲率引入的误差进行改正,获得基准光轴、激光和红外系统在靶标上的精确位置.理论分析和实际测试结果表明,该方法具有理论严密、测量准确度高、工程上易于实现的优点,在2 km范围内基准光轴误差小于4.5″,完全满足多光谱多光轴动态瞄准偏差测试中基准光轴准确度的要求.
Abstract
参考文献

[1] WU Guo-jun,WU Ling-ling,YAN Ya-dong,et al.Coaxiality method for position and angle deviation measurement[J].Acta Photonica Sinica,2007,36(11):2098-2102.吴国俊,吴玲玲,闫亚东,等.一种同时测量平行偏差、倾斜偏差的方法[J].光子学报,2007,36(11):2098-2102.

[2] LI Xia,ZHAO Jian-ke.Pose simulation and calibration of objects in door for high-speed TV measurement system[J].Acta Photonica Sinica,2007,36(7):1360-1363.李霞,赵建科.高速电视姿态测量系统室内目标姿态模拟与标定测量[J].光子学报,2007,36(7):1360-1363.

[3] HUANG Jing,LIU Zhao-hui,SHE Wen-ji,et al.Design of lab test system for boresight of multi-channel optical axes[J].Journal of Applied Optics,2007,28(5):663-666.黄静,刘朝晖,折文集,等.室内多波段光轴一致性测试系统的设计[J].应用光学,2007,28(5):663-666.

[4] CHEN Wen-jian,ZHENG Bao-zhong,YANG Jian-li.Auto-collimating technique of multispectral and multibeam Axes[J].Journal of Applied Optics,2004,25(1):60-64.陈文建,郑宝忠,杨建莉.多光谱多光轴自动校准技术[J].应用光学,2004,25(1):60-64.

[5] FU Yue-gang,WANG Zhi-jian,LI Bo.The method of adjustment and examination of optical LAXIS′ parallelism of multi-spectrum sensor optical system[J].Journal of Changchun Institute of Optics and Fine Mechanics,2001,24(4):11-14.付跃刚,王志坚,李博.多光谱光学系统光学平行性的调校和检验方法探讨[J].长春光学精密机械学院学报,2001,24(4):11-14.

[6] DUAN Xue-ting,BAI Jia-guang,ZHOU Ren-kui.An experimental study on the image quality loss of an objective caused by assemblage stress[C].SPIE,2006,61493D:1-5.

[7] ZENG Chang-e,ZHANG Jun-sheng,SHA Ding-guo,et al.Field test method about optical axis parallelism of multi -axial system[J].Optical Technique,2005,31(Sup):112-117.曾嫦娥,张俊生,沙定国,等.脉冲激光测距机接受轴与瞄准轴平行性测试方法研究[J].光学技术,2005,31(增刊):112-117.

[8] GE Bin,LIU Zhao-hui,HOU Nian-cang.Calculation of the inconsistent optics axis for several optics-measurement instrument[J].Science Technology and Engineering,2007,7(21):5539-5543.鬲滨,刘朝晖,侯年仓.多光学测试设备光轴不一致性测量计算的研究[J].科学技术与工程,2007,7(21):5539-5543.

高明, 侯宏录. 外场多光轴瞄准偏差测试的基准光轴建立方法[J]. 光子学报, 2008, 37(5): 1029. 高明, 侯宏录. Setup of Reference Optical Axis for Aiming Deviation Evaluation with Multi-optical Axis in Field[J]. ACTA PHOTONICA SINICA, 2008, 37(5): 1029.

本文已被 3 篇论文引用