光学仪器, 2013, 35 (5): 75, 网络出版: 2014-01-08   

一种MCP光子计数位置灵敏探测器图像采集系统

Image acquisition system of an MCP photoncounting positionsensitive detector
作者单位
1 中国科学院 长春光学精密机械与物理研究所,吉林 长春130033
2 长春工程学院 理学院,吉林,长春130021
摘要
光子计数位置灵敏探测器在光子、粒子成像领域应用广泛,而图像采集系统是其重要组成部分。在介绍光子计数位置灵敏探测器的工作原理的基础上,分析了实现计数成像功能的软硬件需求,并设计了一套满足该需求的软硬件平台;依据该设计搭建了图像采集系统的硬件平台并采用LabVIEW编写了图像采集软件;最后进行成像实验验证了该套图像采集系统的性能。实验结果显示,基于该图像采集系统光子计数位置灵敏探测器能够将空间频率为7.14 lp/mm的目标分开,表明该图像采集系统实现了其预期功能。
Abstract
Photoncounting positionsensitive detector is widely used in the photon and particle imaging field. Based on the introduction of the operating principle of photoncounting positionsensitive detector, the software and hardware requirement to implement its image function are analyzed, and a platform satisfying this requirement is designed. According to this design, the hardware and software of the image acquisition system are developed. Finally, the performance of this image acquisition system is tested by an imaging testing experiment. The test results show that the positionsensitive counting detector based on this imaging acquisition system can tell apart spatial frequency 7.14 lp/mm object, which indicates that the imaging acquisition system has totally satisfied the functional requirement of the detector.
参考文献

[1] SANDLE B R,BROADFOOT A L,CURTIS C C.The extreme ultraviolet imager investigation for the IMAGE mission[J].Space Science Reviews,2000,91:197-242.

[2] MASATO N,TATSUNDO Y,KOICHIRO T,et al.Interplanetary HeII extremeultraviolet observation on PLANETB[J].Society of PhotoOptical Instrumentation Engineers,1993,32:3033-3037.

[3] 王浩,余有龙,王雪微.光纤可调FP滤波器频率响应特性的实验研究[J].光学仪器,2012,34(6):67-70.

[4] 李奕鑫,黄家政,罗烽庆,等.光学仪器共享与远程控制系统的开发[J].光学仪器,2010,32(1):75-81.

[5] KASLE D B,MORGAN J S.High resolution decoding of multianode microchannel array detector[J].SPIE,1991,1549:52-58.

[6] LAMPTON M,CARLSON C W.Lowdistortion resistive anodes for twodimensional positionsensitive MCP systems[J].Rev Sci Instrum,1979,50:1093-1097.

[7] SIEGLNUND O H W,STOEK J M,MARSH D R,et al.Delay line detectors for the UVCS and SMMER instruments on the SOHO satellite[J].SPIE,1994,2280:89-100.

[8] MARTIN C,JELINSKY P.Wedgeandstrip anode for centroidfinding positionsensitive photon and particle detectors[J].Rev Sci Instrum,1981,52(7):1067-1074.

[9] 何玲平,尼启良,李敏,等.楔条形阳极光子计数探测器成像性能的检测[J].光学 精密工程,2009,17(11):2699-2704.

[10] 樊尚春,乔少杰.检测技术与系统[M].北京:航空工业出版社,2005.

[11] 李霖峰,董磊,张雷,等.基于LabVIEW的光谱自动测试系统[J].光学仪器,2006,28(2):66-70.

[12] 吴强华,王铁岭,董涛.基于LabVIEW的任意波形发生器设计[J].光学仪器,2007,29(2):68-72.

何玲平, 岳巾英, 陈波. 一种MCP光子计数位置灵敏探测器图像采集系统[J]. 光学仪器, 2013, 35(5): 75. HE Lingping, YUE Jinying, CHEN Bo. Image acquisition system of an MCP photoncounting positionsensitive detector[J]. Optical Instruments, 2013, 35(5): 75.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote