Author Affiliations
Abstract
Department of Optoelectronic Engineering, College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha 410073, China
Several results on optical-axis perturbation and elimination of the mismatching error C of a monolithic triaxial ring resonator (MTRR) are reported. Based on the augmented 5£5 ray matrix method, by simultaneously considering axial displacement of a mirror and the misalignments in three planar square ring resonators of a MTRR, the rules of optical-axis perturbation are obtained. The mismatching error C of the MTRR is eliminated. The results obtained are important for cavity design, as well as in the improvement and alignment of MTRR.
空间三轴环形谐振腔 失谐误差 光轴 扰动 140.4780 Optical resonators 140.3410 Laser resonators 140.3370 Laser gyroscopes 140.3560 Lasers, ring 