光谱学与光谱分析, 2014, 34 (2): 350, 网络出版: 2015-01-13   

近红外光纤光谱技术检测西红柿果浆总酸及可溶性糖的研究

Study on Predicting Total Acid Content and Soluble Sugar of Tomato Juice by Near Infrared Optical Fiber Spectrometer Technique
作者单位
1 哈尔滨工程大学理学院, 黑龙江 哈尔滨150001
2 东北农业大学理学院, 黑龙江 哈尔滨150030
3 东北农业大学园艺学院, 黑龙江 哈尔滨150030
摘要
为了探索一种简捷、 快速、 高效的西红柿品质检测方法, 应用近红外光谱技术与光纤传感技术相结合的新方法, 快速测量西红柿果浆样品中营养成分的含量。 实验所用的主要仪器为近红外光纤光谱仪, 波长范围为900~2 500 nm。 以164个西红柿样品为标准样品, 进行了光谱采集及相应的化学值测定。 实验数据采用偏最小二乘法(PLS)进行回归, 建立西红柿果浆中总酸及可溶性糖含量的数学模型, 并对回归方法进行统计分析。 结果为: 西红柿果浆中总酸验证集的决定系数(R2)为0.967, 均方根误差(RMSEC)为0.133, 预测均方根误差(RMSEP)为0.103; 总糖验证集的决定系数(R2)为0.976, 均方根误差(RMSEC)为0.463, 预测均方根误差(RMSEP)为0.460。 均达到了较好的预测结果, 表明该方法对定量分析西红柿果浆中多组分含量是可行的。 基于该方法快速、 简便及可对同一样品多组分含量同时分析的优点,它是一种极具发展前途的传感器, 正在逐渐成为国际传感器领域的研究热点。
Abstract
In order to explore a simple, rapid and efficient tomato quality detection method, in the present experiment near infrared spectroscopy and optical fiber sensing technology were applied to quickly measure the nutrition ingredient content in tomato juice samples. The main instrument used in this experiment was near infrared optical fiber spectrometer in a wavelength range from 900 to 2 500 nm, which measured the absorbance of the tomato juice samples; A collection of one hundred and sixty-four tomato juice samples were selected as the standard samples, the spectra and the corresponding chemical value were measured. Partial least squares (PLS) was adopted to establish the mathematical model of the total acid and soluble sugar content in tomato juice samples, and the regression equation was statistically analysed. The total acid in tomato juice prediction correlation coefficient was 0.967, calibration standard deviation (RMSEC) was 0.133, standard error of prediction (RMSEP) was 0.103; the soluble sugar prediction correlation coefficient is 0.976, calibration standard deviation (RMSEC) was 0.463, and the standard error of prediction (RMSEP) was 0.460. The above data achieved better forecasting results, which showed that the method of quantitative analysis of tomato fruit multicomponent content was feasible. The method is rapid, simple and can do multicomponent analysis on the same sample simultaneously. It is a promising sensor and gradually becoming a international research focus in sensor field.

张丙芳, 苑立波, 张丙秀. 近红外光纤光谱技术检测西红柿果浆总酸及可溶性糖的研究[J]. 光谱学与光谱分析, 2014, 34(2): 350. ZHANG Bing-fang, YUAN Li-bo, ZHANG Bing-xiu. Study on Predicting Total Acid Content and Soluble Sugar of Tomato Juice by Near Infrared Optical Fiber Spectrometer Technique[J]. Spectroscopy and Spectral Analysis, 2014, 34(2): 350.

本文已被 3 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!