X射线荧光分析中X射线管原级能谱分布的测定
[1] . P. Afonin, A. L. Finkelshtein, V. J. Borkhodoev et al.. X-ray fluorescence analysis of rocks by the fundamental parameter method[J]. X-Ray Spectrometry, 1992, 21(2): 69-75.
[2] . Homkimaki, K. Hamalainen, S. Manninen. Quantitative X-ray fluorescence analysis using fundamental parameters: application to gold jewelry[J]. X-Ray Spectrometry, 1996, 25(5): 215-220.
[3] . Nygard, K. Hamalainen, S. Manninen et al.. Quantitative thickness determination using X-ray luorescence: application to multiple layers[J]. X-Ray Spectrometry, 2004, 33(5): 354-359.
[4] . Grgl, P. Wobrauschek, P. Kregsamer et al.. Measurement of the spectral distribution of a diffraction X-ray tube with a solid-state detector[J]. X-Ray Spectrometry, 1992, 21(1): 37-42.
[5] . A. Pella, L. Feng, J. A. An analytical algorithm for calculation of spectral distributions of X-ray tubes for quantitative X-ray fluorescence analysis[J]. X-Ray Spectrometry, 1985, 14(3): 125-135.
[6] . G. Brunetto, J. A. Riveros. A modification of Kramers′ law for the X-ray continuum from thick targets[J]. X-Ray Spectrometry, 1984, 13(2): 60-63.
[7] . Tertian, N. Broll. Spectral intensity distributions from X-ray tubes. Calculated versus experimental evaluations[J]. X-Ray Spectrometry, 1984, 13(3): 134-141.
[8] . Mainardi, Raul A. Barrea. Indirect method of X-ray spectra determination by XRF[J]. X-Ray Spectrometry, 1996, 25(4): 190-195.
[9] R. Tertian, F. Claisse. Principles of Qualitative X-Ray Fluorescence Analysis[M]. London: Heyden, 1982
[10] . Semi-empirical schemes for X-ray mass absorption coefficients used in XRF analysis[J]. Nuclear Science and Techniqeus, 2002, 13(1): 42-49.
[11] Zhang Jiahua, Xu Junquan, Zhu Jieqing.X-Ray Fluorescence Analysis[M]. Beijing: Atomic Energy Press, 1981. 328~376 (in Chinese)
家骅,徐君权,朱节清. X射线荧光分析[M]. 北京: 原子能出版社, 1981. 42~49
[12] Berger M J, Hubbell J H S. Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients, National Bureau of Standards, Gaithersburg, USA. 1995. NISTIR 95-5632
[13] . Escape peaks and internal fluorescence in X-ray spectra recorded with lithium drifted silicon detectors[J]. J. Physics E, 1972, 5: 582-584.
[14] . Mainardi, Raul A. Barrea et al.. Parametric equation for the efficiency curve of germanium detectors[J]. X-Ray Spectrometry, 1998, 27(5): 321-324.
[15] . Rosiger, K. P. Dostal. Determination of the primary energy distribution in XRF analysis[J]. Isotopenpraxis, 1987, 23(4): 131-133.
[16] . Martínez, V. Delgado. Description of X-ray beams using the fluorescence yields of a set of thick targets[J]. X-Ray Spectrometry, 1995, 24(5): 255-259.
[17] . T. Mainardi, R. A. Barrea. Determination of spectral emission of tungsten target tubes measuring X-ray fluorescence from pure elements[J]. Appl. Radiat. Isot., 1995, 46: 497-498.
[18] . T. Mainardi, R. A. Barrea. Indirect method of X-ray spectra determination by XRF[J]. X-Ray Spectrometry, 1996, 25(4): 190-195.
[19] . A .Pells, Liangyuan Feng, J. A. Small. An analytical algorithm for calculation of spectral distributions of X-ray tube for quantitative X-ray fluorescence analysis[J]. X-Ray Spectrometry, 1985, 14(3): 125-135.
[20] Xie Zhongxin, Zhao Zongling, Zhang Yubin. X-Ray Spectroscopic Analysis[M]. Beijing: Science Press, 1982. 328~331 (in Chinese)
谢忠信,赵宗铃,张玉斌. X-射线光谱分析[M]. 北京: 科学出版社, 1982. 328~331
纪新明, 王建业, 贾文红, 朱节清, 黄宜平. X射线荧光分析中X射线管原级能谱分布的测定[J]. 光学学报, 2006, 26(4): 634. 纪新明, 王建业, 贾文红, 朱节清, 黄宜平. Determination of Primary Energy Spectrum Distribution of X-Ray Tube in X-Ray Fluorescence Analysis[J]. Acta Optica Sinica, 2006, 26(4): 634.