用于“聚龙一号”上软X光通量探测的平响应X光二极管
[1] Matzen M K, Sweeney M A, Adams R G, et al. Pulsed-power-driven high energy density physics and inertial confinement fusion research[J]. Physics of Plasmas, 2005, 12: 055503.
[2] Deng J J, Xie W P, Feng S P, et al. Initial performance of the primary test stand[J]. IEEE Trans Plasma Sci, 2013, 41(10): 2580-2583.
[3] Spielman R B, Deeney C, Chandler G A, et al. Tungsten wire-array Z-pinch experiments at 200 TW and 2 MJ[J]. Physics of Plasmas, 1998, 5(5): 2105-2111.
[4] Cuneo M E, Waisman E M, Lebedev S V, et al. Characteristics and scaling of tungsten-wire-array Z-pinch implosion dynamics at 20 MA[J]. Physical Review E, 2005, 71: 046406.
[5] Jonesa B, Deeney C, Coverdale C A, et al. K-shell radiation physics in low- to moderate-atomic-number Z-pinch plasmas on the Z accelerator[J]. Journal of Quantitative Spectroscopy & Radiative Transfer, 2006, 99(1/3): 341-348.
[6] Sabkowska K, Rzadkiewicz J, Szymańska E, et al. Energy shifts of K- and L-lines as spectroscopic diagnostic of Z-pinch plasmas[C]//AIP Conference Proceedings. 2014, 1639: 47-50.
[7] 崔明启, 崔聪悟, 黎刚, 等. 北京同步辐射3B1束线软X射线光源及探测器灵敏度标定[J]. 核电子学与探测技术, 1997, 17(4): 265-268. (Cui Mingqi, Cui Congwu, Li Gang, et al. The characteristics of soft X-ray source on Beijing Synchrotron Radiation Facility and calibration of detector sensitivity. Nuclear Electronics & Detection Technology, 1997, 17(4): 265-268)
[8] Krumrey M, Gerlach M, Scholze F, et al. Calibration and characterization of semiconductor X-ray detectors with synchrotron radiation[J]. Nuclear Instruments and Methods in Physics Research A, 2006, 568(1): 364-368.
[11] Spielman R B, Deeney C, Fehl D L, et al. Fast resistive bolometry[J]. Review of Scientific Instruments, 1999, 70(1): 651-655.
[13] Kornblum H N, Slivinsky V W. Flat-response, subkiloelectronvolt X-ray detector with a subnanosecond time response[J]. Review of Scientific Instruments, 1978, 49(8): 1204-1208.
[14] Tirsell G. Broad-band soft X-ray diagnostic instruments at the LLNL Novette laser facility[R]. UCRL-87946, 1982.
[15] Li Z C, Jiang X H, Liu S Y, et al. A novel flat-response X-ray detector in the photon energy range of 0.1-4 keV[J]. Review of Scientific Instruments, 2010, 81: 073504.
[16] Spielman R B, Anthes J P. A study of bare X-ray diode saturation due to a high fluence X-ray pulse[C]//AIP Conference Proceedings. 1981, 75: 278.
[17] Zhu T, Shang W L, Zhang W H, et al. Quantitative measurement of the proportions of high-order harmonics for the 4B7B soft-X-Ray source at Beijing Synchrotron Radiation Facility[J]. Plasma Science and Technology, 2013, 15(12): 1194-1196.
[18] Zheng L, Zhao Y D, Tang K, et al. A new experiment station on beamline 4B7A at Beijing Synchrotron Radiation Facility[J]. Spectrochimica Acta Part B, 2014, 101: 1-5.
[19] 孙可煦, 易荣清, 江少恩, 等. 同步辐射应用于软X射线探测器的标定[J]. 高能物理与核物理, 2004, 28(2): 205-209. (Sun Kexu, Yi Rongqing, Jiang Shaoen, et al. Calibration of soft X-ray detection with synchrotron radiation. High Energy Physics and Nuclear Physics, 2004, 28(2): 205-209)
王昆仑, 任晓东, 黄显宾, 张思群, 周少彤, 但加坤, 李晶, 徐强, 欧阳凯, 蔡红春, 卫兵, 计策, 丰树平. 用于“聚龙一号”上软X光通量探测的平响应X光二极管[J]. 强激光与粒子束, 2016, 28(4): 045009. Wang Kunlun, Ren Xiaodong, Huang Xianbin, Zhang Siqun, Zhou Shaotong, Dan Jiakun, Li Jing, Xu Qiang, Ouyang Kai, Cai Hongchun, Wei Bing, Ji Ce, Feng Shuping. Flat spectral response XRD for diagnosing soft X-ray flux on PTS[J]. High Power Laser and Particle Beams, 2016, 28(4): 045009.