红外与激光工程, 2016, 45 (3): 0304004, 网络出版: 2016-04-05   

基于历史数据的HJ-1B/IRS热红外通道定标与分析

Calibration and analysis of HJ-1B/IRS thermal infrared channel based on the historical data
作者单位
1 中国科学院遥感与数字地球研究所,北京100101
2 中国矿业大学(北京), 北京 100083
3 环境保护部卫星环境应用中心,北京100094
4 中国农业科学院农业资源与农业区划研究所, 北京 100081
摘要
为获取2013年HJ-1B/IRS热红外通道(B08)绝对辐射定标系数,以TERRA/MODIS为参考传感器,以青海湖为研究区域,采用双通道差分模型进行交叉定标。对比分析不同观测角度、成像时差对定标精度的影响,结果表明,参考传感器观测角度30°以内、成像时差1 h左右交叉定标条件最佳,且回归拟合的定标系数精度最高。通过采用2013年10月26日宁德附近海域星地同步实验数据进行精度验证,结果表明,此定标系数得到的表观辐亮度误差在0.02 Wm-2μm-1sr-1 以内,表观亮温误差在0.15 ℃以内。同时,通过与历年辐射定标系数(2008~2012年)进行对比,所得定标系数精度分别提高98.50%、98.24%、90.21%、20.87%和98.31%。总之,此文定标系数精度较高、结果可靠,可应用于IRS B08通道。
Abstract
To obtain the absolute radiation calibration coefficient of IRS B08 in 2013,TERRA/MODIS was used as the reference sensor, Qinghai lake was taken as the research object, twin-channel difference model was applied to cross-calibration. By comparing the influence of different observation angles and different of imaging receiving time on calibration precision, it can be concluded that the best cross-calibration condition is the observation angle within 30° and the difference of imaging receiving time about 1 hour. Under this condition, calibration accuracy of regression fitting is the highest. According to the precision verification using satellite-ground synchronous experiment data around Ningde area on 26, October, 2013, result shows that error of apparent radiance and brightness temperature is within 0.02 Wm-2μm-1sr-1 and 0.15 ℃ respectively. Besides, compared with the historical calibration coefficients from 2008 to 2010, the new calibration coefficients of 2013 increased by 98.50%, 98.24%, 90.21%, 20.87% and 98.31% respectively. Overall, the obtained calibration coefficient has a high accuracy, that can be used to the IRS B08.
参考文献

[1] Liu Li, Fu Qiaoyan, Shi Tingting, et al. Cross-validation of HJ- 1B infrared channels onboard calibration coefficients using MODIS[J]. Infrared and Laser Engineering, 2014, 43(11): 3638-3645. (in Chinese)

[2] Sun Zhiyuan, Chang Songtao, Zhu Wei, et al. Radiation calibration of infrared system by amendment of inner and outer calibrations[J]. Optics and Precision Engineering, 2015, 23(2): 356-362. (in Chinese)

[3] Jiang G M, Yan H, Ma L L. Intercalibration of SVISSR/FY-2C infrared channels against MODIS/Terra and AIRS/Aqua channels[J]. IEEE Trans Geosci Remote Sensing, 2009, 47: 1548-1558.

[4] Doelling D R, Nguyen L, Minnis P. Calibration comparisons between SEVIRI, MODIS, and GOES data[C]//Proceeding 2004 EUMETSAT Meteorological Satellite Conference, 2004, 6738.

[5] Asem A, Deschamps P Y, Ho D. Calibration of METEOSAT infrared radiometer using split-window channels of NOAA AVHRR[J]. J Atmos Oceanic Tech, 1987, 4(4): 553-562.

[6] Li Jiaguo, Gu Xingfa, Yu Tao, et al. A twin-channel difference model for cross-calibration of thermal infrared band[J]. Science China Technological Sciences, 2012, 55(9): 1-9.

[7] Wan Zhengming, Zhang Yulin, Li Zhaoliang, et al. Preliminary estimate of calibration of the moderate resolution imaging spectroradiometer thermal infrared data using Lake Titicaca [J]. Remote Sensing of Environment, 2002, 80: 497-515.

[8] Sun Ke, Fu Qiaoyan, Qi Xueyong. Radiometric cross-calibration of thermal infrared channel of IRS sensor on HJ-1B satellite[J]. Infrared and Laser Engineering, 2010, 39(5): 785-790. (in Chinese)

杨红艳, 李家国, 朱利, 殷亚秋, 张永红, 雷秋良, 陈宜金. 基于历史数据的HJ-1B/IRS热红外通道定标与分析[J]. 红外与激光工程, 2016, 45(3): 0304004. Yang Hongyan, Li Jiaguo, Zhu Li, Yin Yaqiu, Zhang Yonghong, Lei Qiuliang, Chen Yijin. Calibration and analysis of HJ-1B/IRS thermal infrared channel based on the historical data[J]. Infrared and Laser Engineering, 2016, 45(3): 0304004.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!