摘要
为了更好地满足高功率微波电源技术及高功率脉冲技术的研究需要,研制了高功率柔软型同轴高压馈线。根据馈线的实际应用情况,分别在低压、高压、时域和频域条件下,测试了高压馈线在不同电压和气压下的脉冲功率衰减和脉冲峰值功率传输特性。并对测试结果进行了分析、比较。结果显示,脉冲信号功率衰减和脉冲传输考核均达到了高功率微波驱动电源的使用条件,满足电源系统的需求。
Abstract
A high-voltage soft coaxial feeder is developed in order to meet the research needs of high-power microwave power technology, as well as high power pulse technology. According to the actual application of the feeder, and under the conditions of low voltage, high voltage, time and frequency domains, we test the pulse power attenuation and transmission characteristics of the high-voltage feeder respectively at different voltages and air pressures. The test results are analyzed and compared with each other, which show that the pulse signal power attenuation is 0.03 dB/m, meeting the technical requirement of 0.05 dB/m.
参考文献

[1] 李亚维,马成刚,冯宗明,等.基于LabVIEW的高功率微波驱动源监控系统[J].强激光与粒子束, 2012, 24(3):535-538.(Li Yawei, Ma Chenggang, Feng Zongming, et al. Monitoring system of high power microwave source driver based on LabVIEW. High Power Laser and Particle Beams, 2012, 24(3):535-538)

[2] 陆巍,陈志刚,张现福,等.高功率超宽谱脉冲产生实验[J].强激光与粒子束, 2011, 23(11):2929-2932.(Lu Wei, Chen Zhigang, Zhang Xianfu, et al. Experiment study on high-power microwave ultra-wideband pulse generation. High Power Laser and Particle Beams, 2011, 23(11):2929-2932)

[3] 谢平,廖勇,杨周炳,等.超宽带高功率同轴旋转关节[J].强激光与粒子束, 2011, 23(11):3095-3098.(Xie Ping, Liao Yong, Yang Zhou bing, et al. High-power microwave ultra-wideband coaxial rotary joint. High Power Laser and Particle Beams, 2011, 23(11):3095-3098)

[4] 廖勇,陆巍,杨周炳,等.一种紧凑型高功率宽带微波源[J].强激光与粒子束, 2009, 21(4):605-608.(Liao Yong, Lu Wei, Yang Zhoubing, et al. A compact high power wideband microwave source. High Power Laser and Particle Beams, 2009, 21(4):605-608)

[5] 李亚维,邓建军,谢敏,等.1200 kV重复频率脉冲电源的测试诊断系统[J].强激光与粒子束, 2010, 22(1):207-210.(Li Yawei, Deng Jianjun, Xie Min, et al. Measurement and diagnosis system for 1.2 MV repetitive pulsed power source. High Power Laser and Particle Beams, 2010, 22(1):207-210)

[6] 李亚维,邓建军,谢敏,等.800 kV/100 Hz高功率微波驱动电源控制系统[J].高电压技术, 2009, 35(6):1426-1429.(Li Yawei, Deng Jianjun, Xie Min, et al. Control system of 800 kV/100 Hz high power microwave power supply. High Voltage Engineering, 2009, 35(6):1426-1429)

[7] 刘锡三.高功率脉冲技术[M].北京:国防工业出版社, 2005:307-308.(Liu Xisan. High pulsed power technology. Beijing: National Defense Industry Press, 2005:307-308)

[8] Barker R J. 高功率微波源与技术[M].北京:清华大学出版社,2005:25-27.(Barker R J. High-power microwave sources and technologies. Beijing: Tsinghua University Press, 2005:25-27)

李亚维, 叶超, 马成刚, 谢敏, 刘云涛, 吴烈. 高功率柔软型同轴高压馈线性能测试[J]. 强激光与粒子束, 2013, 25(8): 2147. Li Yawei, Ye Chao, Ma Chenggang, Xie Min, Liu Yuntao, Wu Lie. Performance test of high-power high-voltage soft coaxial feeder[J]. High Power Laser and Particle Beams, 2013, 25(8): 2147.

本文已被 1 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!