Chinese Optics Letters, 2008, 6 (6): 401, Published Online: Jun. 10, 2008  

Dissolved oxygen sensor by using Ru-fluorescence indicator and a U-shaped plastic optical fiber Download: 539次

Author Affiliations
Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800
Abstract
A dissolved oxygen (DO) sensor based on U-shape plastic optical fiber (POF) and dichlorotris (1, 10-phenanthroline) ruthenium ([Ru(dpp)+]2+) as an oxygen indicator was described. Fluorescence intensity and lifetime were measured when the sensor was soaked into a water bath blasted with air with varied O2/N2 ratios. The influence of Ru concentration, annealing time and U-shaped POF curve radius on the system sensitivity was also studied. A two-layer model was proposed to analyze the deviation from linear relation described by Stern-Volmer equation, and to explain the deviation and the dependence of the fluorescence on curvature of U-shape POF. By fitting the experimentally measured sub-linear relation of \tau0/\tau ratio versus oxygen concentration, the proportion of effectively sensitive layer and the Stern-Volmer coefficient can be evaluated to be f=0.59 and KSV=0.61 typically.
References

[1] S. McCulloch and D. Uttamchandani, IEE Proc.-Sci. Meas. Technol. 146, 123 (1999).

[2] X. Chen, Z. Zhong, and Z. Li, Sensors and Actuators B 87, 233 (2002).

[3] D. Sheng, S. Zhao, Y. Han, F. Yue, and J. Huang, Sensor Technology (in Chinese) 23, 381 (2003).

[4] A. Campbell and D. Uttamchandani, IEE Proc.-Sci. Meas. Technol. 151, 291 (2004).

[5] J. R. Lakowicz, Principles of Fluorescence Spectroscopy (Academic Press, New York, 1983).

[6] F. Chu, H. Cai, R. Qu, and Z. Fang, Proc. SPIE 6781, 678108 (2007).

[7] H. Hecht and M. Kolling, Sensors and Actuators B 81, 76 (2001).

[8] D. Marcuse, J. Am. Soc. Opt. 66, 311 (1976).

[9] B. D. MacCraith and C. McDonagh, Journal of Fluorescence 12, 333 (2002).

[10] F. Chu, F. Pang, X. Han, J. Geng, H. Wen, R. Qu, and Z. Fang, Chinese J. Lasers (in Chinese) 34, 229 (2007).

[11] F. Chu, F. Pang, X. Han, J. Geng, H. Wen, R. Qu, and Z. Fang, Chinese J. Lasers (in Chinese) 34, 1263 (2007).

[12] D. P. O'Neal, M. A. Meledeo, J. R. Davis, B. L. Ibey, V. A. Gant, M. V. Pishko, and G. L. Coté, IEEE Sensor Journal 4, 728 (2004).

[13] B. Zhang, An oxygen sensor based on fluorescence quenching (in Chinese) Master dissertation (Wu Han University of Technology, 2003) p.37.

[14] E. R. Carraway, J. N. Demas, and B. A. DeGraff, Analytical Chemistry 63, 337 (1991).

Fenghong Chu, Haiwen Cai, Ronghui Qu, Zujie Fang. Dissolved oxygen sensor by using Ru-fluorescence indicator and a U-shaped plastic optical fiber[J]. Chinese Optics Letters, 2008, 6(6): 401.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!