光学 精密工程, 2007, 15 (10): 1628, 网络出版: 2008-02-18   

精密测角法的线阵CCD相机几何参数实验室标定方法

Calibration of geometric parameters of line-array CCD camera based on exact measuring angle in lab
作者单位
中国科学院,长春光学精密机械与物理研究所,吉林,长春,130033
摘要
建立了线阵CCD相机几何参数标定系统,对该标定方案所用的设备、实验条件、基于精密测角法的算法和精度进行研究.根据标定精度要求,确定了实验室主要测试设备和环境条件.利用高精度二维转台和CCD细分技术测得被标定系统的一系列视场角和对应像高.最后,利用建立的数学模型,应用最小二乘回归的方法,求得相机几何参数.误差分析结果表明:该方法对主距主点的标定精度可以达到μm级,相对畸变的标定精度可以优于1×10-4.该方法可以满足线阵相机的高精度几何标定要求,具有较高的实际应用价值.
Abstract
参考文献

[1] 胡燕,胡莘,王新义,等.偏流角对星载三线阵相机摄影的影响[J].测绘科学,2006,31(4):62-63.HU Y,HU X,WANG X Y,et al..The influence of drift angle on satellite photography of three-line array camera[J].Science o f Surveying and Mapping,2006,31(4):62-63.(in Chinese)

[2] 王冬,冯文灏,卢秀山,等.基于多片空间后方交会的CCD相机检校[J].测绘科学,2006,31(4):64-66.WANG D,FENG W H,LUX SH,et al..CCD camera calibration based on space resection with multi-image[J].Science of Surveying and Mapping,2006,31(4):64-66.(in Chinese)

[3] 扬秉新.国外航天侦察相机和测绘相机发展概况[J].航天返回与遥感,1998,19(2):16-24.YANG B X.The development survey of foreign space reconnaissance camera and mapping camera[J].Spacecraft Kecovery & Remote Sensing,1998,19(2):16-24.(in Chinese)

[4] OHLHOF T,KORNUS W.Geometric calibration of digital three-line CCD cameras[C].International Archives of Photogrammetry and Remote Sensing,Como,Italy,1994,30:71-81.

[5] PACEY R E,WALKER A S,SCHEIDT M.Calibration of analog and digital airborne sensors at LH systems[C].Proceedings of the 1999 ASPRS Annual Conference,Portland,Oregon,1999:950-956.

[6] SCHUSTER R.Sensor calibration and geometric calibration of a three line stereo camera[C].International Archives of Photogrammetry and Remote Sensing,Como,Italy,1994,30:265-271.

[7] DORRER E,MAIER W,UFFENKAMP V.Analytical kinematic sensor orientation of MOMS-02 linear array stereo imagery[J].Intergrated Sensor Orientation,1995:261-273.

[8] LEHNER M,KORNUS W.Digital photogrammetric processing of MOMS-02/D2 magery[J].ISPRS Congress Commission 111/WG2,1996,7:9-19.

[9] CHEN T,SHIBASAKI R,MORITA K.High precision georeference for airborne three-line scanner(TLS) imagery[C].3rd International Image Sensing Seminar on New Developments in Digital Photogrammetry,Gi fu,Japan,2001:71-82.

[10] 李广泽,刘金国,郝志航.基于双正交小波的星点细分定位方法研究[J].光学精密工程,2005,13(增):218-221.LI G Z,LIU J G,HAO ZH H.Research of subpixel subdivision location algorithm for star image based on biorthogonal wavelet[J].Opt.Precision Eng.,2005,13(Supp.):218-221.(in Chinese)

[11] 刘金国,李杰,郝志航.三线阵相机亚像元精度精度几何标定方法研究[J].光电工程,2004,31(1):36-39.LIU J G,LI J,HAO ZH H.Study on a geometric calibration method for three-linear-array CCD camerawith subpixel accuracy[J].Opto-Electronic Engineering,2004,31 (1):36-39.(in Chinese)

[12] 费业泰.误差理论与数据处理[M].北京:机械工业出版社,2003.FEI Y T.Error Theory and Data Processing[M].Beijing:China Machine Press,2003.(in Chinese)

[13] 王家骐.光学仪器总体设计[M].长春:长春光机所,2003.WANG J Q.Total Design of Optic Instrument[M].Changchun:Changchun Institute of Optic,Fine Mechanics and Physics,2003.(in Chinese)

[14] 王金堂,乌崇德.国外几种星载光学遥感器的发展情况简介[J].航天返回与遥感,2002,23(2):15-20.WANG J T,WU CH D.Introduction of some foreign spaceborne optical remote sensing[J].Spacecraft Kecovery & Remote Sensing,2002,23(2):15-20.(in Chinese)

吴国栋, 韩冰, 何煦. 精密测角法的线阵CCD相机几何参数实验室标定方法[J]. 光学 精密工程, 2007, 15(10): 1628. 吴国栋, 韩冰, 何煦. Calibration of geometric parameters of line-array CCD camera based on exact measuring angle in lab[J]. Optics and Precision Engineering, 2007, 15(10): 1628.

本文已被 15 篇论文引用
被引统计数据来源于中国光学期刊网