光电子技术, 2002, 22 (3): 164, 网络出版: 2006-06-08
红外焦平面阵列两点线性校正法的研究
Research of Two-point Linear Correction in IRFPAs
红外焦平面 非均匀校正 两点线性校正法 误差 infrared focal plane nonuniformity correction tow-point linear correction error
摘要
所有的红外焦平面阵列必须进行非均匀性校正.两点线性校正法是最先开发研究的方法之一,也是使用最广泛的校正方法.然而由于响应率的非线性和噪声等原因两点线性校正后仍然存在误差.本文分析并计算了两点线性校正误差,并指出了减少非均匀校正误差的方法.
Abstract
All infrared focal plane arrays (IRFPAs) require nonuniformity correction. Two-point linear correction is one of the earlier studied and widely used methods. However, nonlinearity of the responsibility and noise result in the nonuniformity error. This paper describes and calculates the error resulted from noise and nonlinearity. A method to reduce the nonuniformity error is also presented.
参考文献
[1] Friedenberg A, Goldblall I. Nonuniformity two-point linear correction errors in infrared focal plance arrays[J]. Opt. Eng., 1998;37:1 251-1 253
[2] 胡晓梅.红外焦平面探测器的非均匀性与校准方法研究[J].红外与激光工程,1999;28:13-19
[3] 熊辉.红外焦平面阵列非均匀校正算法研究[J].系统工程与电子技术,1998;12:40-43
[4] Volodymyr, Borovytsky, Valery Fesenlo. Non-uniformity correction in infrared imaging systems[J]. SPIE, 2000;4 148:273-278
[5] 沈晓燕,皮德富.一种红外焦平面非均匀性校正改进方法的研究[J].红外技术,2002;24:4-7
沈晓燕, 皮德富, 赵琦. 红外焦平面阵列两点线性校正法的研究[J]. 光电子技术, 2002, 22(3): 164. 沈晓燕, 皮德富, 赵琦. Research of Two-point Linear Correction in IRFPAs[J]. Optoelectronic Technology, 2002, 22(3): 164.