Photonics Research, 2020, 8 (7): 07001079, Published Online: Jun. 3, 2020  

Great enhancement of image details with high fidelity in a scintillator imager using an optical coding method Download: 635次

Huijuan Xia 1,2†Yanqing Wu 1,3,4,*†Lei Zhang 1,2†Yuanhe Sun 1,2†Zhongyang Wang 3†Renzhong Tai 1,3,5,*†
Author Affiliations
1 Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai 201800, China
2 University of Chinese Academy of Sciences, Beijing 100049, China
3 Shanghai Advanced Research Institute, Chinese Academy of Sciences, Shanghai 201204, China
4 e-mail: wuyanqing@zjlab.org.cn
5 e-mail: tairenzhong@zjlab.org.cn
Figures & Tables

Fig. 1. Schematic of an X-ray scintillator imager based on the use of the proposed high-spatial-frequency spectrum enhanced reconstruction (HSFER) method. A two-dimensional (2D) encoder is used to extract the middle-high-frequency and high-frequency components of the image generated in the scintillator. The image is decoded by a PSF/OTF of the encoder.

下载图片 查看原文

Fig. 2. (a) Areas below the dashed, dotted, and solid curves represent the parameter zones that allow the +1st-order diffraction to occur for the two-dimensional (2D) encoder periods of 600, 450, and 300 nm, respectively. This shows that the encoder with a 300 nm period can yield a maximum suppression of the +1-order diffraction compared with the other two encoders. In fact, no +1st-order diffraction occurs with a 300 nm period in FDTD simulations. (b) The green area shows the parameter zone that allows the 1st-order diffracted waves to be accepted by the optical system, whereby the encoder with the 300 nm period is selected. The angle 33.0° represents the total reflection angle. The FDTD simulation results of the transverse electric (TE) and transverse magnetic (TM) modes are also shown here. (c) MTFs are used for the evaluation of the performance of this system. The thick curve represents the MTF of the case with the 2D encoder, while the thin one represents the case without the 2D encoder. Obviously, the spectrum is extended considerably by the encoder. The fc value is the cutoff frequency determined by the equivalent camera pixel size, which is equal to (1.3  μm)1 in our experiment. The green area indicates the extra high-frequency information received from the encoder.

下载图片 查看原文

Fig. 3. Experimental setup with the HSFER imager. The fluorescent pattern produced by the X rays through the sample was first encoded by a 2D encoder, then imaged by the camera, and finally decoded by an iteration method. The inset upper-left subfigure shows the scanning electron micrograph of the 2D encoder: a YAG:Ce film covered with a 2D SiNx array.

下载图片 查看原文

Fig. 4. Radiographs of the resolution chart obtained with a 3 s exposure (the dose is 4×108  phs/mm2). (a), (b) Imaging results for a resolution chart without and with the HSFER method, respectively. (c), (d) Magnified views of the regions of interest in (a) and (b), respectively. (e) PSDs of the images in (a) and (b), whereby the red and the blue curves represent the cases with and without the HSFER, respectively, and fc2 is the cutoff frequency for the thin curve. (f) Normalized PSD with respect to the one without HSFER, thus showing that the cutoff frequency is extended to fc1. The fn is the spatial frequency at which the average effect of the deconvolution algorithm begins to work. The dashed line describes the denoising effect for frequencies much higher than fn.

下载图片 查看原文

Fig. 5. Radiographs of the resolution chart obtained with a 0.5 s exposure (the dose is 6×107  phs/mm2). (a), (b) Imaging results without and with the HSFER method, respectively. (c), (d) Magnified views of the regions of interest in (a) and (b), respectively. (e) PSDs of the images in (a) and (b), whereby the red and blue curves represent the cases with and without the HSFER, respectively. (f) PSDs with respect to the case at which the HSFER was not used.

下载图片 查看原文

Fig. 6. Radiographs of the gill of a dehydrated zebrafish following an exposure of 1 s (the dose is 1.2×108  phs/mm2). More detailed structures in the regions of interest can be found in (b) the HSFER image compared with that in (a) the conventional image.

下载图片 查看原文

Huijuan Xia, Yanqing Wu, Lei Zhang, Yuanhe Sun, Zhongyang Wang, Renzhong Tai. Great enhancement of image details with high fidelity in a scintillator imager using an optical coding method[J]. Photonics Research, 2020, 8(7): 07001079.

引用该论文: TXT   |   EndNote

相关论文

加载中...

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!