红外技术, 2016, 38 (11): 980, 网络出版: 2016-12-20   

太阳辐射对管道表面发射率测量影响分析

Effect of Solar Radiation on Emissivity Measurement of Pipeline Surface
作者单位
1 东北石油大学,黑龙江 大庆 163318
2 大庆石化公司信息技术中心,黑龙江 大庆 163318
摘要
发射率是影响管道表面散热损失一个重要物理量,其测量过程受环境影响较大,其中,太阳辐射是影响发射率测量结果的一个重要因素。本文从红外热像仪测温原理着手,根据表面辐射传输原理给出了管道表面发射率与辐射能量之间的关系,修正了测量管道表面发射率的方法,通过实验研究了太阳辐射对管道表面发射率测量的影响。结果表明太阳辐射对管道表面发射率测量影响较大,其测量偏差超过25%。
Abstract
The emissivity is an important physical quantity which affects the heat loss of the pipeline surface and the measurement process is greatly influenced by the environment. The solar radiation is one of the important factors that affect the result of emissivity measurement. Based on the principle of infrared thermal imaging temperature measurement, the relationship between pipeline surface emissivity and radiation energy is given according to the principle of surface radiation transmission. Method for measuring surface emissivity of pipeline is corrected. The influence of solar radiation on the surface emissivity of the pipeline is studied. The results show that the solar radiation has a great influence on the surface emissivity of the pipeline and the measuring deviation is more than 25%.
参考文献

[1] 余龙红. 催化裂化装置管线散热损失估算及分析[J]. 炼油技术与工程, 2004, 34(11): 38-41.

    YU Longhong. Evaluation and analysis of pipeline heat loss in fcc unit[J]. Petroleum Refinery Engineering, 2004, 34(11): 38-41.

[2] 孙晓刚, 李云红. 红外热像仪测温技术发展综述[J]. 激光与红外, 2008, 38(2): 101-104.

    SUN Xiaogang, LI Yunhong. Review of the development of temperature measurement technology with infrared thermal imger[J]. Laser and Infrared, 2008, 38(2): 101-104.

[3] 张健, 杨立, 刘慧开. 环境高温物体对红外热像仪测温误差的影响[J]. 红外技术, 2005, 27(5): 419-422.

    ZHANG Jian, YANG Li, LIU Huikai. Effect of environment object on infrared temperature measurement[J]. Infrared Technology, 2005, 27(5): 419-422.

[4] Nina P Umnyakova. Influence of surface emissivity on the heat loss through the wall behind the heater[J]. Procedia Engineering, 2015, 148: 797-802.

[5] A K A Shati, S G Blakey, S B M Beck. The effect of surface roughness and emissivity on radiator output[J]. Energy and Building, 2011, 43: 400-406.

[6] 白敬晨, 于庆波, 胡贤忠, 等. 基于红外热像仪的物体表面发射率测 量方法[J]. 东北大学学报, 2013, 34(12): 1747-1750.

    BAI Jingchen, YU Qingbo, HU Xianzhong. et al. Surface emissivity measurement technique based on infrared thermal imager[J]. Journal of Northeastern University, 2013, 34(12): 1747-1750.

[7] 张澎, 郭玲, 王琦, 等. 基于标准黑体的物体表面发射率计算方法研 究[J]. 红外, 2014(9): 6-10.

    ZHANG Peng, GUO Ling, WANG Qi. et al. Study of calculation method about surface emissivity of objects based on standard blackbody[J]. Infrared, 2014(9): 6-10.

[8] 张彤, 代晓东, 陈春生, 等. 非全视场条件下目标红外发射率的测试 和计算[J]. 红外与激光工程, 2015, 44(1): 1-5.

    ZHANG Tong, DAI Xiaodong, CHEN Chunsheng. et al. Measurement and calculation of infrared emissivity of target with non-full field of view[J]. Infrared and Laser Engineering, 2015, 44(1): 1-5.

[9] WANG Hui, CHEN Dejiang, WANG Guolin, et al. Measurement technology for material emissivity under high temperature dynamic heating conditions[J]. Measurement, 2013, 46(10): 4023-4031.

[10] De Campo. Emissivity measurements on aeronautical alloys[J]. Journal of Alloys and Compounds, 2010, 489(2): 482-487.

[11] 齐宏, 牛春洋, 阮立明, 等. 不透明材料波段法向发射率在线测量方 法[J]. 实验技术与管理, 2014, 31(12): 31-34.

    QI Hong, NIU Chunyang, RUAN Liming. et al. Research on online measurement method of opaque material band normal emissivity. Experimental Technology and Management, 2014, 31(12): 31-34.

[12] 刘华, 艾青, 夏新林, 等. 毫米级非均匀粗糙表面红外发射率测量[J]. 工程热物理学报, 2013, 34: 317-319.

    LIU Hua, AI Qing, XIA Xinlin, et al. Measurement of infrared emissivity of surfaces with non-uniform millimeter-scale roughness[J]. Journal of Engineering Thermophysics, 2013, 34: 317-319.

[13] 魏巍, 赵卉. 金属材料表面发射率测量方法研究[J]. 工业计量, 2015, 25(6): 55-57.

    WEI Wei, ZHAO Hui. Research on measurement method of surface emissivity of metallic materials[J]. Industrial Measurement, 2015, 25(6): 55-57.

[14] 宋健, 郝小鹏, 原遵东, 等. 基于控制环境辐射的黑体辐射源发射率 测量方法研究[J]. 中国激光, 2015, 42(9): 23-26.

    SONG Jian, HAO Xiaopeng, YUAN Zundong. et al. Blackbody source emissivity measurement method based on controlling surroundings radiation[J]. Chinese Journal of Lasers, 2015, 42(9): 23-26.

[15] 刘连伟, 杨淼淼, 樊宏杰, 等. 一种表面发射率的测量方法研究[J]. 激光与红外, 2014, 44(2): 152-157.

    LIU Lianwei, YANG Miaomiao, FAN Hongjie, et al. Method for surface emissivity measurement, Laser and Infrared, 2014, 44(2): 152-157.

[16] 杨立. 红外热像仪测温计算与误差分析[J]. 红外技术, 1999, 21(4): 20-24.

    YANG Li. Calculation and error analysis of temperature measurement using thermal imager[J]. Infrared Technology, 1999, 21(4): 20-24.

[17] 吴燕燕, 罗铁苟, 黄杰, 等. 基于红外热像仪测温原理的物体表面发 射率计算[J]. 直升机技术, 2011(4): 25-30.

    WU Yanyan, LUO Tiegou, HUANG Jie, et al. Calculation of object emissivity based on measuring temperature principle of thermal imager[J]. Helicopter Technique, 2011(4): 25-30.

吴国忠, 李宏佳, 吕妍, 齐晗兵, 李栋. 太阳辐射对管道表面发射率测量影响分析[J]. 红外技术, 2016, 38(11): 980. WU Guozhong, LI Hongjia, LV Yan, QI Hanbing, LI Dong. Effect of Solar Radiation on Emissivity Measurement of Pipeline Surface[J]. Infrared Technology, 2016, 38(11): 980.

本文已被 2 篇论文引用
被引统计数据来源于中国光学期刊网
引用该论文: TXT   |   EndNote