光散射学报, 2017, 29 (2): 172, 网络出版: 2017-07-05  

光纤湿敏球腔传感采集校准组合装置的技术问题初探

Probe into the Technical Problems of the Optical Fiber Humidity Sensor Acquisition Calibration Equipment
作者单位
上海电子信息职业技术学院,上海 201411
摘要
本文研制了一种光纤耦合湿敏监测装置,此装置采用MEMS微位移传感器来进行湿敏微腔耦合位置的辅助校准,再用光强传感器对耦合输出的光波进行湿度感测和量化。这种基于MEMS位移传感器的耦合位置校准方法与现有的校准平台相比,无需外加太多繁琐、庞大的仪器装置,就可获得精准又便捷的校准效果。另外在传感系统后端可进行可编程控制程序开发,用加载的数据采集卡来实现湿度敏感单元敏感量的采集与显示。
Abstract
Humidity sensitive monitoring device with optical fiber coupling was developed in this paper.This device adopts the MEMS micro displacement sensor aided calibration for humidity sensitive micro-cavity coupling location,and the light intensity sensor is used for humidity output quantization.Comparing with other docking calibration platform,this kind of MEMS displacement sensor based coupling position calibration method needs not any huge instrument device,can obtain precise and convenient calibration results.In the sensor system back-end programmable control procedures can be developed,with the loading of data acquisition card to realize the humidity sensitive unit quantity acquisition and display.
参考文献

[1] 赵大博,栗大超,李源,等.三维微触觉MEMS传感器测试校准的方法与系统[J].传感技术学报,2006,19(5): 1505-1508.(Zhao Dabo,Li Dachao,Lee Yuan,et al.Three dimensional micro tactile MEMS sensor test calibration method and system[J].Sensing Technology Journal,2006,19(5): 1504-1508.)

[2] 付旭,周兆英,熊沈蜀,等.基于EKF的多MEMS传感器姿态测量系统[J].清华大学学报: 自然科学版,2006,46(11): 1857-1859.(Fu Xu,Zhou Zhaoying,Xiong Shenshu,et al.Attitude measurement system of multi MEMS sensors based on EKF[J].Journal of Tsinghua University: Natural Science Edition,2006,46(11): 1857-1859.)

[3] Cenk A,Andrei M S.Experimental evaluation and comparative analysis of commercial variable-capacitance MEMS accelerometers[J].Micromech Microeng,2003,13(1): 634-636.

[4] Satyajit S,Peng Zhangb,Hyoung J C.Significance of electrode-spacing in hydrogen detection for tin oxide-based MEMS sensor[J].International Journal of Hydrogen Energy,2008,33(1): 470-475.

[5] 杨睿,於文华,鲍洋,等.消逝场耦合圆柱形微腔中回音壁模式结构的实验研究[J].物理学报,2008,57(10): 6412-6415.(Yang Rui,Yu Wenhua,Bao Yang,et al.Experimental study on whispering gallery mode structure in evanescent field coupled cylindrical micro cavity[J].Journal of Physics,2008,57(10): 6412-6415.)

[6] 董春华.回音壁模式微腔量子电动力学的实验研究[D].中国科学技术大学,博士学位论文,2011年.(Chun Hua-dong.Experimental study of whispering gallery mode cavity quantum electrodynamics[D].University of science and technology of China,doctoral dissertation,2011.)

[7] Liu Shurong,WU Yanji,Xu Lei.Relationship between vibration error and structural resonance in closed loop FOG[J].Infrared and Laser Engineering,2008,37(S): 256-269.

[8] Song Ningfang,Zhang Chunxi,Li Lijing,et al.Analysis of vibration error in digital closed-loop fiber optic gyroscope[J].Journal of Beijing University of Aeronautics and Astronautics,2004,30(8): 702-704.

[9] 杨旭光.动力调谐陀螺仪角度传感器的设计[D].硕士学位论文,天津大学,2010.6.(Yang Xuguang.Design of the angle sensor for dynamic tuned gyroscope[D].Master's Degree Thesis,Tianjin University,2010,6.)

[10] 马青.电感式角位移传感器的研制与结构分析[D].硕士学位论文,东南大学,2004.3.(Ma Qing.Design and structure analysis of inductive angular displacement sensor[D].master's degree thesis,Southeast University,2004,3.)

葛羽屏. 光纤湿敏球腔传感采集校准组合装置的技术问题初探[J]. 光散射学报, 2017, 29(2): 172. GE Yuping. Probe into the Technical Problems of the Optical Fiber Humidity Sensor Acquisition Calibration Equipment[J]. The Journal of Light Scattering, 2017, 29(2): 172.