红外技术, 2016, 38 (12): 1067, 网络出版: 2017-01-03   

半透明体后被测物体红外辐射测温误差分析

Temperature Measurement Error Analysis of Infrared Radiation of the Object Being Measured After Semitransparent Object
作者单位
海军工程大学动力工程学院, 湖北 武汉 430033
摘要
根据红外辐射理论和红外热成像仪的测温原理,考虑环境、大气、物体透射辐射等多方面影响,建立了红外热像仪对半透明体后被测物体测温的数学模型,分析了半透明体反射率、透射率及其误差、被测物体发射率及其误差对热像仪测温误差的影响,提出了减少半透明体后被测物体红外辐射测量误差的几种对策,提出了提高带红外检测窗口电气柜中带电部件的红外测温准确性的方法。
Abstract
Based on the theory of infrared radiation and the infrared thermography, the mathematical correction model of the infrared radiation temperature measurement of the object to be measured after the semitransparent object is established with the effects caused by the atmosphere, surroundings, radiation of transimissivity and many other factors taken account of. The effects of the emissivity, transimissivity and measurement error are analyzed on temperature measurement error of the infrared thermography. Several strategies for reducing the error of infrared radiation measurement of the transmission medium for the semitransparent object are presented. Several methods for improving the accuracy of infrared temperature measurement of the charged components in the electrical cabinet with infrared detection window are presented.
参考文献

[1] 杜科, 刘相忠, 王玲, 等. 红外窗口在密闭电气柜测温中的应用[J]. 科技传播, 2012(12): 89-94.

    DU Ke, LIU Xiangzhong, WANG Ling, et al. Application on infrared window in the temperature measurement of the closed electric cabinet[J]. Science and Technology Communication, 2012(12): 89-94.

[2] 乐晓倩. 红外窗口在开关柜上的应用研究[J].硅谷, 2013,14: 76-85.

    LE Xiaoqian. Study on the application of infrared window in switch cabinet[J]. Silicon Valley, 2013, 14: 76-85.

[3] 杨立. 红外热像仪测温计算与误差分析[J].红外技术, 1999, 21(4): 20-24.

    YANG Li. Calculation and error analysis of temperature measurement[J]. Infrared Technology, 1999, 21(4): 20-24.

[4] 杨立, 寇蔚, 刘慧开. 热像仪测量物体表面辐射率及误差分析[J].激光与红外, 2002, 32(1): 43-45.

    YANG Li, KOU Wei,LIU Huikai.. Surface emissivity measurement an error analysis using infrared thermography[J]. Laser & Infrared, 2002, 32(1): 43-45.

[5] 寇蔚, 杨立. 热测量中误差的影响因素分析[J].红外技术, 2001, 23(3): 32-34.

    KOU Wei,YANG Li. Error analysis of infrared measurement[J]. Infrared Technology, 2001, 23(3): 32-34.

[6] 张勇, 王新赛, 贺明. 距离对红外热像仪测温精度的影响及误差修正[J].红外, 2011, 32(2): 24-28.

    ZHANG Yong, WANG Xinsai, He Ming. Influence of distance on temperature measurement accuracy of infrared thermal imager and error correction[J]. Infrared, 2011, 32(2): 24-28.

[7] 张健, 杨立, 刘慧开. 环境高温物体对红外热像仪测温误差的影响[J].红外技术, 2005, 27(5): 419-422.

    ZHANG Jian, YANG Li, LIU Huikai. Effect of environmental object on infrared temperature measurement[J]. Infrared Technology, 2005, 27(5): 419-422.

赵小龙, 杨立, 苗雨. 半透明体后被测物体红外辐射测温误差分析[J]. 红外技术, 2016, 38(12): 1067. ZHAO Xiaolong, YANG Li, MIAO Yu. Temperature Measurement Error Analysis of Infrared Radiation of the Object Being Measured After Semitransparent Object[J]. Infrared Technology, 2016, 38(12): 1067.

本文已被 1 篇论文引用