激光与光电子学进展, 2018, 55 (8): 081205, 网络出版: 2018-08-13  

基于光学传递函数的头戴显示器图像畸变检测 下载: 672次

Image Distortion Detection of Head-Mounted Display Based on Optical Transform Function
作者单位
华侨大学信息科学与工程学院福建省光传输与变换重点实验室, 福建 厦门 361021
摘要
头戴显示器光学系统由于焦距短、视场大而容易产生图像畸变。提出了一种头戴显示器的图像畸变测量方法,采用单位矩阵的傅里叶变换图像作为标准测试图形,应用傅里叶变换分析了头戴显示器光学传递函数与测量图像球面化畸变的关系,得到了形状不变的关系曲线。实验测量了5种头戴显示器的图像球面化畸变,得到的负球面化枕形畸变范围为-22%~-65%。结果表明:头戴显示器的球面化图像畸变量CVR与方格成像实验的畸变量D具有一定的线性关系,且球面化图像畸变量CVR的测量简单,能体现头戴显示器的整体图像畸变程度。该研究结果对头戴显示器的图像显示质量测量具有一定的参考价值。
Abstract
The optical system of the head-mounted display is prone to image distortion generally because its focal length is short and its field of view is wide. An image distortion measurement method of head-mounted display is presented. A Fourier transform image of unit matrix is chose as standard test pattern, and the relationship between optical transfer function of head-mounted display and spherical distortion of image is analyzed with Fourier transform. Based on this method, the similar relationship curve are obtained. Image spherical distortion of five kinds of head-mounted display are measureds, and the negative-pinched pincushion distortion is obtained which ranged from -22% to -65%. The results show that spherical distortion CVR of the head-mounted display has linear relation with distortion quality of grid image measurement. However, the measuring method for spherical image distortion is simple, and the measuring results can reflect the distortion of the whole image. The results are of great reference value for measuring image quality of head-mounted display.
参考文献

[1] 孙天成, 顾华荣. 基于多层半透明薄膜的三维显示技术研究[J]. 光学学报, 2018, 38(3): 0312001.

    Sun T C, Gu H R. Study on three-dimensional display technology based on multi-layer semitransparent thin film[J]. Acta Optica Sinica, 2018, 38(3): 0312001.

[2] 陆颖隽. 虚拟现实技术在数字图书馆的应用研究[D]. 武汉: 武汉大学, 2013.

    Lu Y J. Application of virtual reality to digital library[D]. Wuhan: Wuhan University, 2013.

[3] 张晓兵, 安新伟, 刘璐, 等. 头盔显示器的发展与应用[J]. 电子器件, 2000, 23(1): 51-59.

    Zhang X B, An X W, Liu L, et al. Development and application of helmet-mounted displays[J]. Journal of Electron Devices, 2000, 23(1): 51-59.

[4] 夏金瑶. 基于WebGL的EAST可视化系统[D]. 合肥: 中国科学技术大学, 2017.

    Xia J Y. The EAST visualization system based on WebGL[D]. Hefei: University of Science and Technology of China, 2017.

[5] 胡佳洁, 李素梅, 常永莉, 等. 基于显著区域的立体图像舒适对比度范围的测量[J]. 光学学报, 2018, 38(2): 0215001.

    Hu J J, Li S M, Chang Y L, et al. Measurment of comfortable contrast range of stereo image based on salient region[J]. Acta Optica Sinica, 2018, 38(2): 0215001.

[6] International committee for display metrology (ICDM) information display measurement standard. IDMS version 1.03[S]. San Jose: International Committee for Display Metrology, 2012.

[7] ISO Copyright Office. ISO 9241-305 Ergonomics of human-system interaction. Part 305: optical laboratory test methods for electronic visual displays[S]. Switzerland:[s.n.], 2008.

[8] IISO Copyright Office. ISO 9241-303 Ergonomics of human-system interaction. Part 303: Requirements for electronic visual displays Annex E; virtual display-performance objectives[S]. Switzerland:[s.n.], 2008.

[9] Jrvenp T, Salmimaa M. Optical measurements of different near-eye display types[J]. Sid Symposium Digest of Technical Papers, 2016, 47(1): 1056-1059.

[10] Chen W, Xiao X, Li Z Z, et al. An image quality evaluation method of near-eye displays[J]. Sid Symposium Digest of Technical Papers, 2016, 47(1): 1060-1063.

[11] 沈丽丽, 张晶, 范科峰, 等. 立体显示器质量测试与性能分析研究[J]. 光子学报, 2013, 42(2): 219-223.

    Shen L L, Zhang J, Fan K F, et al. Reasearch on quality analysis and measurement of stereoscopic display[J]. Acta Optica Sinica, 2013, 42(2): 219-223.

[12] 王丛, 金杰, 沈丽丽. 自由立体显示器的光学性能测量与研究[J]. 激光技术, 2016, 40(3): 367-371.

    Wang C, Jin J, Shen L L.Measurement and research of optical characteristics of auto-stereoscopic display[J]. Laser Technology, 2016, 40(3): 367-371.

[13] 朱瑶. 光学系统的星点检验方法[J]. 红外, 2004(9): 31-37.

    Zhu Y. Star test for optical system[J]. Infrared, 2004(9): 31-37.

[14] 党丽苹, 戴炳明, 唐树刚. 光学系统分辨率自动检测的研究[J]. 光子学报, 1995, 24(3): 278-281.

    Dang L P, Dai B M, Tang S G. Reseakch on the auto-detecting resolution of optical system[J]. Acta Photonica Sinica, 1995, 24(3): 278-281.

[15] 张艳. 数字刀口检测技术的研究[D]. 成都: 四川大学, 2004.

    Zhang Y. Studies on digital knife-edge testing technology[D]. Chengdu: Sichuan University, 2004.

[16] 李宏壮, 王志臣, 王富国, 等. 大口径望远镜波像差的外场检验方法[J]. 光子学报, 2012, 41(1): 39-42.

    Li H Z, Wang Z C, Wang F G, et al. Method of wavefront error test in the outfield for large aperture telescope[J]. Acta Photonica Sinica, 2012, 41(1): 39-42.

[17] 曾明智, 李海峰. 投影机镜头的MTF实时检测系统[J]. 光电工程, 2008, 35(2): 134-139.

    Zeng M Z, Li H F. Real-time MTF measurement system for projection lens[J]. Opto-Electronic Engineering, 2008, 35(2): 134-139.

[18] 刘炼雄, 胡昌华, 何川, 等. 一种改进的基于直线特征的非量测畸变校正方法[J]. 光学学报, 2017, 37(9): 0915001.

    Liu L X, Hu C H, He C, et al. An improved non-metric distortion calibration method based on straight line characteristics[J]. Acta Optica Sinica, 2017, 37(9): 0915001.

王孝艳, 刘楚嘉, 漆宇, 庄其仁. 基于光学传递函数的头戴显示器图像畸变检测[J]. 激光与光电子学进展, 2018, 55(8): 081205. Wang Xiaoyan, Liu Chujia, Qi Yu, Zhuang Qiren. Image Distortion Detection of Head-Mounted Display Based on Optical Transform Function[J]. Laser & Optoelectronics Progress, 2018, 55(8): 081205.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!