光学学报, 2006, 26 (4): 541, 网络出版: 2006-05-17  

用合肥800 MeV同步辐射光源标定氘灯的光谱辐射亮度

Spectral Radiance Calibration of Deuterium Lamp Utilizing the Hefei 800 MeV Synchrotron Radiation
作者单位
1 中国科学院长春光学精密机械与物理研究所应用光学国家重点实验室, 长春 130031
2 中国科学院研究生院, 北京 100039
3 中国科技大学国家同步辐射实验室, 合肥 230021
摘要
利用合肥800 MeV电子存储环同步辐射(HESYR)作为紫外真空紫外光谱辐射测量的绝对标准,标定了传递标准氘灯光源的光谱辐亮度。采用德国国家物理技术研究院(PTB)的数据处理及不确定度分析方法,得到了两支氘灯在115~300nm波段的光谱辐亮度数据,其相对定标不确定度为12.1%。详细分析了相关参量对定标不确定度的贡献,指出辐射计量系统偏振特征量的不确定度贡献最大。在164~300 nm波段,德国德国国家物理技术研究院在BESSYⅡ同步辐射装置上标定的绝对光谱辐亮度值与本实验在中国合肥同步辐射装置上标定的绝对光谱辐亮度值之间一致性优于±20%,在给定的不确定度范围内两光谱辐射标准定标结果一致。
Abstract
The spectral radiance of transfer standard-deuterium lamp is calibrated using Hefei 800 MeV electron storage ring synchrotron radiation (HESYR) as an absolute UV-VUV spectral radiometric standard. The data processing and uncertainty analysis method of PTB is employed, in 115~300 nm the spectral radiance values of two deuterium lamps are obtained, and the overall uncertainty for D2 lamp calibration is 12.1%. A detailed analysis of the contributions to this uncertainty points out that the major part is caused by the uncertainty of the polarization properties of the radiometric instrumentation. In the range of 164~300 nm the D2 lamp absolute spectral radiant distribution obtained using HESYR China and that derived from BESSYⅡGermany have a discrepancy within ±20%. They are consistent within the given uncertainties.
参考文献

[1] Li Zhigang, Wang Shurong, Li futian. Development of Fourior transform spectrometer for ultraviolet and vacuum ultraviolet regions[J]. Acta Optica Sinica, 2001, 21(4): 459~462 (in Chinese)
李志刚,王淑荣,李福田. 紫外真空紫外傅里叶光谱仪的研制[J]. 光学学报, 2001, 21(4): 459~462

[2] Gao Hongyi, Chen Jianwen, Xie Haonglan. Experimental results of X-ray diffraction enhanced phase contrast imaging[J]. Acta Optica Sinica, 2004, 24(8): 1151~1152(in Chinese)
高鸿奕,陈建文,谢红兰. X射线衍射增强相衬成像的实验结果[J]. 光学学报, 2004, 24(8): 1151~1152

[3] Li Zahozhou, Zheng Xiaobing, Wu Haoyu. Temperature characteristics research of high-precision spectral radiometer standard detector[J]. Acta Optica Sinica, 2004, 24(3): 401~407(in Chinese)
李照洲,郑小兵,吴浩宇. 高精度光谱辐射标准探测器的温度特性研究[J]. 光学学报, 2004, 24(3): 401~407

[4] . Stock, J. Fischer, R. Friedrich et al.. Present state of the comparison between radiometric scales based on three primary standards[J]. Metrologia, 1993, 30: 439-449.

[5] . Arnold , G. Ulm. Electron storage ring BESSY as a source of calculable spectral photon flux in the X-ray region[J]. Rev. Sci. Instrum., 1992, 63(1): 1539-1542.

[6] . Richter, J. Hollandt, U. Kroth et al.. Source and detector calibration in the UV and VUV at BESSY Ⅱ[J]. Metrologia, 2003, 40: S107-S110.

[7] . Fischer, M. Kuhne, B. Wende. Spectral radiant power measurements of VUV and soft X-ray sources using the electron storage ring BESSY as a radiometric standard source[J]. Appl. Opt., 1984, 23(23): 4252-4259.

[8] . Schwinger. On the classical radiation of accelerated electrons[J]. Phys. Rev., 1949, 75: 1912-1921.

[9] Xing Jin, Wang Shurong, Li Futian. Comparisons between radiometric scales on UV-VUV radiant standard light sources[J]. Optics and Precision Engineering, 2004, 12(4): 373~379 (in Chinese)
邢进,王淑荣,李福田. 紫外真空紫外辐射标准光源的比对[J]. 光学精密工程, 2004, 12(4): 373~379

[10] . D. Saunders, W. R. Ott, J. M. Bridges. Spectral irradiance standard for the ultraviolet: the deuterium lamp[J]. Appl. Opt., 1977, 17(4): 593-600.

[11] . R. Blevin. Diffraction losses in radiometry and photometry[J]. Metrologia, 1970, 6(2): 39-44.

邢进, 李福田, 王淑荣, 霍同林, 周红军, 刘颖. 用合肥800 MeV同步辐射光源标定氘灯的光谱辐射亮度[J]. 光学学报, 2006, 26(4): 541. 邢进, 李福田, 王淑荣, 霍同林, 周红军, 刘颖. Spectral Radiance Calibration of Deuterium Lamp Utilizing the Hefei 800 MeV Synchrotron Radiation[J]. Acta Optica Sinica, 2006, 26(4): 541.

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!